ABB 1SDA083196R1 Moulded Case Circuit Breaker - DSA
Part Number: 1SDA083196R1
Quick Summary
ABB 1SDA083196R1 Moulded Case Circuit Breaker provides reliable overload and short‑circuit protection for industrial switchgear and control panels. Engineers often struggle with downtime from undersized protection and mounting constraints in space‑constrained panels. This unit carries RoHS and REACH declarations and TSCA compliance, supporting sustainable, globally compliant deployments. As part of the SACE Formula DSA family with four poles and a TMF release, it aligns with IEC 60947‑2 standards, simplifying design and installation while ensuring predictable protection. The combination of plug‑and‑play terminals, front access, and compact footprint reduces installation costs and supports scalable automation deployments.
Product Information
Extended Description
1SDA083196R1 ABB: C.BREAKER SACE FORMULA A1N 125 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 32-400 A (DVP)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644899417
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
1 kg
Package Level 1 Gross Weight
1.05 kg
Product Main Type
SACE FORMULA DSA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Number of Poles
4P
Rated Current (In)
32 A
Release
TMF
Remarks
ATLAS - FORMULA DVP
Short-Circuit Performance Level
N
Sub-type
A1
Data Sheet, Technical Information
SACE FORMULA DSA IEC Low voltage molded-case circuit-breakers up to 630A IEC 60947-2 Standard
Instructions and Manuals
Installation Instructions Formula A1/III-IV
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Four-pole TMF release with front terminals enables neat wiring and faster commissioning, delivering clearer fault paths and improved maintenance access. This feature translates into reduced wiring errors, lower risk of misconnection, and shorter panel assembly times in new builds and retrofit projects. It is particularly well suited for SACE Formula DSA installations in control cabinets and motor control centers, where space efficiency and reliable protection matter most.32 A rated current with four poles ensures balanced protection for three‑phase loads and helps achieve selective coordination with upstream devices. The TMF release provides stable tripping behavior under overload and short‑circuit conditions, minimizing nuisance trips and downstream process interruptions. The 4P configuration makes it ideal for distribution boards and machine panels that require per‑phase isolation and clear fault indication. RoHS and REACH declarations plus TSCA and CMRT support global procurement and regulatory compliance. This reduces supplier risk and simplifies documentation for audits and certifications. The safety‑critical nature of low‑voltage molded‑case breakers benefits from consistent environmental data across the ABB SACE range, improving your ESG reporting. Compact dimensions and weight—101.6 mm width, 130 mm height, 60 mm depth, and about 1 kg net weight—facilitate easier panel fitting and replacement. Front terminals simplify field wiring and service, while the EAN 8015644899417 and minimum order quantity of one piece streamline purchasing and stock control. The combination supports fast, predictable panel upgrades, with reduced field install time. As a member of the SACE Formula DSA family, this device meets IEC 60947‑2 standards for molded‑case breakers up to 630 A, ensuring compatibility with ABB and partner components across control panels. Documentation includes a data sheet and installation instructions, plus WEEE packaging disposal guidance to support responsible end‑of‑life handling. This alignment yields lower total cost of ownership through standardization and easier maintenance.
Get a Quick Quote for a ABB 1SDA083196R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA083196R1?
Enquire Now
FAQs
Install with the front terminals accessible for wiring, ensuring correct phase alignment and tightening torque per the installation instructions. Verify the 4P configuration matches your panel design and leave space for terminal connections and lever access. Use appropriate shielded wiring where necessary and confirm compatibility with SACE Formula DSA mounting patterns to avoid misalignment during retrofits.
The unit is a four‑pole moulded case circuit breaker with a 32 A rated current (In) and TMF release. It provides robust overload and short‑circuit protection, suitable for three‑phase loads in distribution and motor control applications. Its N short‑circuit performance level and front terminal design support reliable protection and straightforward wiring in industrial panels.
Yes. The product carries RoHS and REACH declarations for ABB SACE circuit breakers, plus TSCA declarations and CMRT documentation. This multi‑axis compliance supports global supply chains, simplifies regulatory audits, and enables responsible procurement across regions with differing environmental and material requirements.
Best suited for industrial control panels, motor control centers, and distribution boards in manufacturing and process environments. The 4P TMF‑released design with 32 A rating offers reliable phase protection, easy wiring through front terminals, and compatibility with IEC 60947‑2 low‑voltage molded‑case standards, enabling scalable, modular protection of automation systems.
Included are the data sheet and installation instructions for SACE Formula DSA molded‑case breakers, RoHS/REACH declarations, CMRT, and TSCA documentation. It also references WEEE packaging disposal information for end‑of‑life handling. This suite supports compliance, traceability, and efficient maintenance across global operations.