ABB 1SDA097654R1 Moulded Case Circuit Breaker - CE Declaration of Conformity Tmax T5
Part Number: 1SDA097654R1
Quick Summary
ABB 1SDA097654R1 Moulded Case Circuit Breaker is a high‑reliability overcurrent protection device for low‑voltage switchgear and industrial panels. Engineers often struggle with nuisance trips and inconsistent protection when upgrading protection schemes, leading to downtime and compliance risks. This MCCB carries CE conformity via EC Declaration of Conformity for the Tmax T5 generation, RoHS compliance under EU directives, and CMRT reporting for responsible sourcing along with TSCA declarations. Its compact 186 mm width, 205 mm height, and 103.5 mm depth support efficient enclosure layouts while a 1 piece minimum order simplifies procurement. Designed for ABB SACE Tmax T systems, it integrates with existing protection schemes and speeds up commissioning in new builds and retrofits.
Product Information
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Minimum Order Quantity
1 piece
Customs Tariff Number
85362000
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
6.65 kg
Package Level 1 Width
285 mm
Package Level 1 Height
225 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Gross Weight
6.75 kg
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Remarks
ATLAS
Data Sheet, Technical Information
SACE Tmax. T Generation. Low voltage moulded-case circuit-breakers from 250 A up to 1600 A
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
Instructions and Manuals
Installation instructions Tmax T5
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Four‑pole construction provides synchronized protection for three‑phase loads, reducing coordination gaps and trip risk. The business impact is safer, more predictable disconnections and simpler panel wiring, ideal for motor control centers and distribution boards in manufacturing environments. The product supports CE conformity, RoHS, REACH, CMRT, and TSCA declarations, which reduces audit time, simplifies cross‑border projects, and strengthens sustainable procurement programs. Its compact footprint and weight—186 mm width, 205 mm height, 103.5 mm depth; 6.65 kg—enable higher panel densities and easier installation in tight switchgear enclosures, improving overall installation efficiency. Documentation is clear and readily available, with installation instructions and data sheets that accelerate commissioning and reduce field wiring errors. Logistics are streamlined with a minimum order quantity of one piece and standard tariff 85362000, supporting predictable inventory and procurement workflows.
Get a Quick Quote for a ABB 1SDA097654R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA097654R1?
Enquire Now
FAQs
Power down the panel, verify system rating, and mount the MCCB in the designated slot. Connect line and load cables per the Tmax T5 installation instructions, ensure correct busbar alignment, torque connections to specification, and secure the device with the supplied hardware. Verify proper clearance and perform a functional test before commissioning.
This is a four‑pole MCCB designed for low‑voltage protection in three‑phase systems. It features a compact 186 mm width, 205 mm height, and 103.5 mm depth, with a weight of 6.65 kg. It belongs to the SACE Tmax T generation and has a minimum order quantity of 1 piece, with tariff code 85362000.
Yes. The four‑pole design supports three‑phase motor protection with coordinated tripping, helping prevent fault propagation. It integrates with existing ABB SACE Tmax T protection schemes and is compatible with typical motor control centers and distribution boards used in manufacturing environments.
The device carries CE conformity via EC Declaration of Conformity Tmax T5, RoHS compliance under EU directives, REACH declaration, CMRT for conflict minerals, and a TSCA declaration, ensuring regulatory readiness for global projects and supply chain audits.
Expect reduced downtime from reliable, predictable tripping and easier compliance documentation. The compact form factor simplifies panel redesigns, while standard installation instructions and data sheets speed commissioning. A single piece MOQ and clear tariff/packaging data improve procurement accuracy and inventory control, contributing to lower total cost of ownership.