ABB 1SDA100072R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA100072R1
Manufacturer
ABB
Part number
1SDA100072R1

Quick Summary

ABB 1SDA100072R1 is a 3-pole moulded case circuit breaker for industrial power distribution and machinery protection. Engineers often wrestle with ensuring fast arc-quench, reliable protection, and straightforward maintenance in compact panel layouts. This device carries CE conformity, RoHS compliance, and TSCA declarations, with EPD data supporting sustainability claims and supplier due diligence. Built on the robust SACE Tmax XTXT2 platform, it offers a 63 A nominal rating with 690 V AC compatibility and front-terminal accessibility, enabling faster wiring and safer commissioning. For panel-builders and integrators, the combination of lifecycle data, ABB EcoSolutions support, and clear installation guidelines helps reduce downtime and total cost of ownership while maintaining compliance across global sites.

Product Information

Extended Description

1SDA100072R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP DIP LIG R 63 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3063CFF000XXX
EAN
8056221001267
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8056221001267
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.7 W
Rated Current (In)
63 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip Dip LIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT2 platform with 3P fixed front terminals provides reliable, space-efficient protection for industrial power distribution panels, allowing quicker wiring and safer maintenance in tight enclosures. This translates to reduced commissioning time and lower field labor costs for panel builders assembling control cabinets in manufacturing environments. The 63 A nominal rating with a 160 A Iu capability supports load growth without over-sizing, enabling designers to optimize panel density while preserving fault protection. Application: Motor starters, machinery feeders, and transformer protection in process lines benefit from consistent tripping performance and predictable available current.Feature → Business Impact → Application: High short-circuit performance up to 100 kA Icu at low voltages (and up to 70 kA at higher voltages) delivers robust protection against short circuits, reducing upgrade frequency and equipment damage. Application: Critical line feeds to pumps, conveyors, and presses in automotive and packaging lines benefit from rapid isolation during faults.Feature → Business Impact → Application: Electrical durability rated at 8000 cycles and mechanical durability at 25,000 cycles, plus low standby power loss (1.7 W per pole), extend service life and lower energy losses caused by nuisance trips. Application: Continuous process lines and high-cycle feeders where reliability and energy efficiency matter.Feature → Business Impact → Application: IEC 60947-2 compliance, CE labeling, RoHS and REACH declarations, and TSCA visibility help meet global regulatory requirements and customer-supplier audits. This reduces risk during audits and shortens time-to-approval for international projects. Application: Global factories and multi-site installations requiring standardized low-voltage protection across regions.Feature → Business Impact → Application: Compact footprint (90 mm W x 130 mm H x 82.5 mm D) with front-terminal wiring eases panel layout and retrofit projects, enabling easier upgrading of existing installations without major cabinet modifications. Application: Retrofit and modernization of legacy switchgear in medium-to-large distribution panels across manufacturing and infrastructure sectors.

Get a Quick Quote for a ABB 1SDA100072R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA100072R1? Enquire Now

FAQs

The XT2H uses fixed front terminals for straightforward wiring. Mount the breaker in a compatible 3P slot, connect conductors to the front terminals with appropriate torque, and follow the manufacturer’s installation instructions. Ensure compliance with IEC 60947-2 and verify proper alignment with adjacent devices to avoid wiring pinching or overheating.
Key specs include a rated current of 63 A, rated operational voltage of 690 V AC, rated insulation voltage of 1000 V, and Icu up to 100 kA depending on voltage. Electrical durability is 8000 cycles and mechanical durability 25000 cycles, with a power loss of approximately 1.7 W per pole.
Yes. It is designed for 690 V AC operation with three poles and front-terminal connections, making it suitable for industrial power distribution panels, machine feeders, and similar high-voltage low-voltage protection applications.
The product carries CE conformity (EC Declaration of Conformity Tmax XT2), RoHS compliance, REACH declarations, TSCA statement, and EPD data for Tmax XT XT2. These support regulatory compliance, environmental considerations, and supplier due diligence across global sites.
With electrical durability up to 8000 cycles and mechanical durability up to 25000 cycles, combined with low standby power, the breaker offers predictable maintenance windows and reduced replacement frequency, contributing to lower total cost of ownership in high-cycle production environments.