ABB 1SDA100086R1 Moulded Case Circuit Breaker - Icu 100 kA
Part Number: 1SDA100086R1
Quick Summary
ABB 1SDA100086R1 Moulded Case Circuit Breaker provides reliable 690 V AC protection for industrial power distribution. Maintenance and downtime are common pain points; this MCCB offers front-terminal access and a fast Ekip Dip LIG release to simplify fault isolation. It complies with IEC 60947-2 and CE, with RoHS and REACH declarations, while offering an EPD for environmental transparency. Designed for the SACE Tmax XT family, the 4P 25 A device delivers robust protection with high short‑circuit capacity and low energy loss, supporting efficient, compliant designs.
Product Information
Extended Description
1SDA100086R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP DIP LIG R 25 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4025CFF000XXX
EAN
8056221001403
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.5 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8056221001403
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.8 W
Rated Current (In)
25 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip Dip LIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
4P 25 A current rating with front-terminal connection provides compact, scalable protection for distributed panels. The device supports 690 V AC operating voltage and 1000 V rated insulation, enabling reliable performance across diverse industrial networks. This makes it an ideal replacement or upgrade in retrofit projects where space and performance matter.Front terminals simplify field wiring, testing, and future maintenance, reducing installation time and panel downtime. The ergonomic design also improves reliability in tight equipment rooms where rear access is impractical. Compatibility with SACE Tmax XT family ensures consistent protection across the plant's low-voltage fleet.High fault current tolerance is delivered by Ics up to 100 kA and Icu up to 100 kA across standard voltages. This capability minimizes arc flash risk and protects downstream equipment during overload events. Engineers can confidently coordinate upstream protection, motor starters, and transformers within a single XT-series solution.Release system Ekip Dip LIG provides fast, repeatable tripping with robust front-access operation. The mechanism supports straightforward maintenance and quick component replacement during scheduled shutdowns. Customers benefit from predictable opening times around 30 ms and reduced service interventions.Compliance and sustainability are built in with IEC 60947-2, CE conformity, RoHS and REACH declarations. Environmental disclosures include EPD data and a recyclability rate of approximately 55.70%, supporting closed-loop programs. End-of-life disassembly guidance helps plants plan decommissioning and material recovery.Physical footprint is panel-friendly: 120 mm wide, 130 mm high, 82.5 mm deep, and 1.5 kg. Packaging ships as a single-piece carton with 8056221001403 EAN, enabling straightforward inventory control. Ordering is simple with a minimum of 1 piece and US/Canada code XT2HE4025CFF000XXX.As part of the SACE Tmax XT ecosystem, XT2H devices integrate with standard DIN-rail layouts for quick upgrades. Front-terminal, fixed-configuration design minimizes wiring errors and accelerates commissioning. This combination delivers reliable protection, lower lifecycle costs, and streamlined spare-part planning across facilities.
Get a Quick Quote for a ABB 1SDA100086R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA100086R1?
Enquire Now
FAQs
Yes. This 4P front-terminal XT2H device is designed for DIN-rail mounted electrical panels and aligns with SACE Tmax XT family dimensions, ensuring straightforward retrofits and simple wiring checks during commissioning.
Key specs include a 25 A current rating, 4 poles, 690 V AC rated operational voltage, Ui 1000 V, Uimp 8 kV, and Ics/Icu up to 100 kA. These figures enable robust protection across typical industrial loads and fault scenarios.
Ideal for industrial distribution panels, transformer protection, and motor control circuits in manufacturing and process environments, particularly where front-terminal wiring and quick maintenance are prioritized.
The device complies with IEC 60947-2 and CE marking, with RoHS and REACH declarations. It also provides environmental disclosures (EPD) and end-of-life guidance for recycling and disposal planning.
Low energy loss per pole (0.8 W) and fast trip times (~30 ms) reduce energy waste and downtime. Front-access design speeds maintenance, while standardized XT2H components simplify spares and lifecycle management.