ABB 1SDA100574R1 Accessory for Tmax XT5 - IEC60947-2
Part Number: 1SDA100574R1
Quick Summary
The ABB 1SDA100574R1 accessory enables shunt release for Tmax XT5 circuit breakers in industrial control panels. Engineers often struggle with mis-matched releases that cause nuisance trips and slow fault isolation. It adheres to IEC 60947-2 standards, with CE declaration, RoHS compliance, and CMRT/TSCA reporting. This accessory for Tmax XT installations delivers reliable protection, easier maintenance, and alignment with ABB EcoSolutions.
Product Information
Extended Description
1SDA100574R1 ABB: THERMOMAGNETIC RELEASE THREE-POLE IN AC-DC TMA R 320 I3=1600...3200 XT5
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Norway)
4380335
EAN
8056221006507
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1.35 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
120 mm
Package Level 1 Height
180 mm
Package Level 1 Depth / Length
225 mm
Package Level 1 Gross Weight
1.514 kg
Package Level 1 EAN
8056221006507
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT5
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
320 A
Release
TMA
Release Type
TM
Setting Range
224…320 A
Standards
IEC60947-2
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT5-XT6
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
The 1SDA100574R1 offers a 3-pole AC/DC shunt release capable of handling up to 320 A with a setting range of 224–320 A. Feature → Business Impact → Application: Tight, adjustable trip coordination reduces nuisance trips and improves fault isolation in high-load Titan XT5 configurations, enabling faster maintenance and lower downtime in critical production lines. This device is IEC 60947-2 compliant and CE-certified, simplifying regulatory audits and reducing compliance risk during panel builds and retrofits. With loose or configurable mounting, installation flexibility translates into faster commissioning and easier field risk management on crowded switchgear rails. The accessory supports XT5 shunt-release workflows, delivering predictable performance in power distribution applications and aiding preventative maintenance programs. Industry context shows these shunt-release options minimize unplanned outages in data centers, manufacturing floors, and process lines. Compatibility with RoHS and CMRT data further strengthens supplier responsibility in supply-chain audits, while TSCA declarations support U.S. regulatory alignment. The result is a dependable, standards-driven upgrade path for Tmax XT families.
Get a Quick Quote for a ABB 1SDA100574R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA100574R1?
Enquire Now
FAQs
To install the 1SDA100574R1, ensure the Tmax XT5 starter is de-energized and that the panel allows for three-pole mounting. Connect the AC/DC release wiring per the XT5 release assembly instructions, verify the setting range is within 224–320 A, and secure the release unit to the circuit-breaker assembly. Finally, perform a functional test to confirm correct release action under controlled conditions.
Key specs include a three-pole AC/DC release, rated current of 320 A, setting range from 224 to 320 A, release type TMA, and compatibility with Tmax XT5. It adheres to IEC 60947-2 standards, includes a CE declaration, RoHS compliance, and CMRT/TSCA documentation for regulatory and supply-chain transparency.
Yes. The 1SDA100574R1 is designed as a shunt release accessory for Tmax XT5, supporting 3P, AC/DC operation with a 320 A nominal rating and a 224–320 A adjustable setting, ensuring proper coordination and protection in high-current XT5 configurations.
The accessory carries IEC 60947-2 conformity, CE declaration, RoHS status per EU Directive 2011/65/EU and 2015/863, CMRT for conflict minerals, and TSCA declarations. Environmental info notes packaging disposal considerations and ABB EcoSolutions alignment, helping you meet internal sustainability and regulatory goals.
By implementing the 1SDA100574R1, you achieve improved fault isolation and reduced nuisance trips, which translates to less unplanned downtime and faster repair cycles. The standardized IEC 60947-2 compliance streamlines audits, while configurable settings and XT5 compatibility simplify commissioning and ongoing maintenance, delivering lower total cost of ownership for Tmax XT-based installations.