ABB 1SDA100575R1 Accessory - TMA 400-4000 XT5 IEC60947-2
Part Number: 1SDA100575R1
Quick Summary
The 1SDA100575R1 Accessory is a Tmax XT5 shunt release that provides three-pole protection for low-voltage power distribution. It addresses retrofit and upgrade challenges by offering compact form, straightforward wiring, and reliable operation that minimizes downtime. Certified to IEC60947-2 and RoHS/REACH requirements, with CMRT and TSCA declarations, it supports global compliance. For integrators and procurement teams, this accessory adds robust XT5 compatibility and predictable performance, helping reduce risk and total cost of ownership.
Product Information
Extended Description
1SDA100575R1 ABB: THERMOMAGNETIC RELEASE THREE-POLE IN AC-DC TMA R 400 I3=2000...4000 XT5
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Norway)
4380336
EAN
8056221006514
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1.35 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
120 mm
Package Level 1 Height
180 mm
Package Level 1 Depth / Length
225 mm
Package Level 1 Gross Weight
1.514 kg
Package Level 1 EAN
8056221006514
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT5
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
400 A
Release
TMA
Release Type
TM
Setting Range
280…400 A
Standards
IEC60947-2
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT5-XT6
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Three-pole thermomagnetic release (TMA) for Tmax XT5. Business Impact: Delivers robust protection with fast, reliable tripping across each phase, reducing fault impact and downtime. Application: Ideal for main feeders and distribution panels in industrial installations. Feature: Rated current 400 A with a setting range of 280–400 A. Business Impact: Provides precise overcurrent protection and flexible coordination with downstream devices, optimizing protection schemes and minimizing nuisance trips. Application: Motor drives, transformers, and large loads in power distribution systems. Feature: AC/DC current type with loose or configurable installation. Business Impact: Supports mixed electrical environments, simplifying inventory and installation logistics while enabling quick retrofits. Application: Mixed manufacturing lines and renewable energy interfaces where both AC and DC protections are required. Feature: IEC60947-2 compliance plus RoHS, REACH, CMRT, and TSCA declarations. Business Impact: Ensures regulatory alignment and global market access, reducing compliance risk and procurement delays. Application: Global OEMs and multi-site operations requiring standardized low-voltage protection. Feature: Compatibility with XT5 and product family metadata (Accessories for Tmax XT). Business Impact: Streamlines sourcing, simplifies spare-part planning, and accelerates field service with proven XT5 interoperability. Application: New installations and legacy upgrades within Tmax XT-based protection schemes. Feature: Detailed packaging and logistics data (EAN, minimum order, weight). Business Impact: Improves procurement accuracy, shipping planning, and inventory control. Application: Central warehouses, distributor networks, and just-in-time manufacturing setups.
Get a Quick Quote for a ABB 1SDA100575R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA100575R1?
Enquire Now
FAQs
The 1SDA100575R1 is designed for loose or configurable mounting on Tmax XT5 assemblies. Begin by confirming 3P AC/DC compatibility, then connect per the XT5 release instructions. Ensure the setting range is tuned to the protected circuit (280–400 A) and verify wiring integrity and terminal torque. Always follow local electrical codes and the IEC60947-2 guidelines to complete a safe, reliable installation.
Key specs include a 400 A rated current, three poles (3P), AC/DC current type, and a setting range from 280 to 400 A. It is designed as a Thermomagnetic Release (TMA) for Tmax XT5 and complies with IEC60947-2. The unit supports flexible installations in AC or DC protected circuits and is compatible with XT5 protective schemes.
Yes. As a Tmax XT5 shunt release accessory, it is specifically suited for motor feeders and main distribution circuits within XT5 protection systems. Its 3P configuration and adjustable 280–400 A setting range enable precise coordination with upstream and downstream protection, improving reliability and minimizing unplanned outages in industrial power distribution.
The accessory is IEC60947-2 compliant and carries RoHS and REACH declarations, along with CMRT and TSCA information for supply-chain transparency. This combination supports global regulatory requirements and helps manufacturers and integrators meet cross-border standards when installing Tmax XT5 protection devices.
Using the 1SDA100575R1 shunt release provides predictable, reliable protection, reducing downtime from nuisance trips and enabling quicker field servicing due to XT5 interoperability. The documented specifications and packaging data also simplify procurement, inventory planning, and lifecycle management, contributing to lower total cost of ownership over the system’s lifetime.