ABB 1SDA102135R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA102135R1
Quick Summary
The ABB 1SDA102135R1 Moulded Case Circuit Breaker protects low-voltage power distribution in industrial panels. It reduces wiring complexity and maintenance by combining front terminals with a reliable Ekip Dip LSI release. This device carries CE conformity, UL/CSA certification, and RoHS compliance, supporting safe integration into global panels. Designed for reliable protection, it aligns with SACE Tmax XT family standards and offers 4 poles for thorough distribution fault isolation. The unit balances compact form with performance, helping procurement teams simplify stocking while meeting regulatory requirements and energy-efficiency goals. Together with REACH declarations, it supports sustainable deployments in modern manufacturing environments.
Product Information
Extended Description
1SDA102135R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 100 A
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
EAN
8015644026462
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8015644026462
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Power Loss
at Rated Operating Conditions per Pole 4.20 W
Rated Current (In)
100 A
Rated Frequency (f)
50/60 Hz
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Release
Ekip Dip LSI
Release Type
EL
Short-Circuit Performance Level
H
Standards
UL
Sub-type
XT2
Interrupting Rating acc. to UL489
(240 V AC) 150 A | (480 V AC) 65 A | (600 V AC) 25 A
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | XT2-XT4 Trip Unit Ekip Dip LSI-LSIG
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The four-pole, front-terminal design simplifies panel wiring and speeds up installation, delivering a tangible reduction in commissioning time and potential wiring errors in transformation and distribution panels. This directly improves site productivity and reduces labor costs during panel upgrades while maintaining high isolation and protection standards for critical loads. The Ekip Dip LSI release provides precise, solid-state tripping behavior, minimizing nuisance trips and enabling dependable protection for motors and process equipment in manufacturing and automation environments. With a rated current of 100 A and a rated voltage of 690 V AC, the unit supports common industrial feeder configurations, delivering reliable protection with manageable heat generation and clear overload indications for maintenance planning. Power loss per pole at rated conditions is 4.20 W, contributing to cooler enclosures and longer component life in dense switchgear assemblies. Durability figures of 8,000 electrical cycles and 25,000 mechanical cycles help justify longer replacement intervals and lower total cost of ownership. RoHS and REACH compliance, along with EPD and recyclability data, support sustainable procurement and regulatory alignment for global operations. Installation compatibility with XT Tmax XT line ensures straightforward integration into existing ABB ecosystems, and the front-terminal fixed design reduces panel footprint while enabling compliant wiring layouts in compact switchgear rooms.
Get a Quick Quote for a ABB 1SDA102135R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA102135R1?
Enquire Now
FAQs
The 1SDA102135R1 is a four-pole MCCB with front terminals, designed for fixed mounting in low‑voltage panels. Ensure proper alignment with standard DIN rail or panel cutouts, connect the front terminals per ABB wiring diagrams, and verify 690 V AC system compatibility. Use correct torque on terminal screws and observe clearance for heat dissipation to maintain protection performance.
Key specs include a rated current of 100 A, rated voltage of 690 V AC, rated insulation voltage of 1000 V AC, and a rated frequency of 50/60 Hz. It is a 4P device with Ekip Dip LSI release, UL/CSA certified, and designed for low‑voltage distributions in industrial environments.
Yes. The 1SDA102135R1 is a 4P molded case circuit breaker from the SACE Tmax XT family, ideal for transformer protection and main distribution in industrial panels. Its front-terminal design, solid-state LSI release, and 100 A rating support reliable overcurrent protection with fast response, while meeting UL/CSA standards for safe integration into global installations.
Yes. The device carries RoHS compliance and REACH declarations, and a CE declaration of conformity for Tmax XT2. This ensures regulatory alignment for European and global deployments, facilitating compliant procurement and streamlined approvals in manufacturing and automation projects.
The Ekip Dip LSI release provides precise, solid-state protection with predictable trip characteristics, reducing unplanned downtime. Electrical durability reaches about 8,000 cycles and mechanical durability up to 25,000 cycles, supporting longer service intervals. Coupled with measured power loss of 4.20 W per pole, this design helps manage heat and extends enclosure life in continuous-operation environments.