ABB 1SDA102781R1 Accessory - Tmax XT UL489 Certified

Part Number: 1SDA102781R1
Manufacturer
ABB
Part number
1SDA102781R1

Quick Summary

ABB 1SDA102781R1 Accessory for Tmax XT enables reliable shunt release integration in power distribution panels. Engineers often struggle with coordinating protective devices in compact layouts, risking misconfiguration and difficult maintenance. This accessory carries UL489 certification, CE conformity, and RoHS/REACH declarations to simplify regulatory compliance. Designed for a four-pole AC/DC release with front-terminal connections, it speeds installation and reduces wiring errors. In procurement terms, clear packaging, a 1-piece minimum order, and XT5/SACE Tmax XT compatibility support predictable sourcing and lower total cost of ownership.

Product Information

Extended Description

1SDA102781R1 ABB: THERMOMAGNETIC RELEASE FOUR-POLE IN AC-DC TMA R 400 I3=2000...4000 UL/CSA A FULLY RATED NEUTRAL XT5
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221024532
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1.3 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
179 mm
Package Level 1 Height
179 mm
Package Level 1 Depth / Length
223 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8056221024532
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT5
Suitable for Product Class
SACE Tmax XT
Version
F
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
400 A
Release
TMA
Release Type
TM
Setting Range
280…400 A
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT5-XT6
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Four-pole AC/DC release (4P) delivers complete coordination for high-current circuits up to 400 A. Business Impact: enhances protection selectivity and reduces nuisance trips, enabling safer startups and minimized downtime in critical power infrastructure. Application: ideal for SACE Tmax XT panels in industrial automation and data centers. Feature: Loose or configurable configuration with front-fixed terminals provides installation flexibility and faster retrofits. Business Impact: simplifies wiring, reduces install errors, and shortens commissioning time. Application: upgrades and retrofits in existing XT5 systems without extensive rewiring. Feature: Broad compliance portfolio including UL489, CE, RoHS, REACH, CMRT, and TSCA declarations. Business Impact: lowers regulatory risk across global projects and accelerates cross-border deployments. Application: multinational facilities demanding strict environmental and safety standards. Feature: Detailed packaging and logistics data including EAN, weight, and MOQ. Business Impact: streamlines procurement, inventory planning, and logistics costs. Application: steady supply for OEMs and distributors handling Tmax XT accessories. Feature: Comprehensive technical documentation and manuals integration with XT5-XT6 releases. Business Impact: reduces training time and misinterpretation, supporting faster maintenance cycles. Application: service teams and integrators working with Tmax XT protective systems.

Get a Quick Quote for a ABB 1SDA102781R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA102781R1? Enquire Now

FAQs

Install the four-pole AC/DC release using the front-terminal connection as specified in the data sheet. Ensure compatibility with XT5 modules and Tmax XT panels, and complete mechanical seating before wiring. The 1-piece MOQ and documented EAN simplify procurement and reduce installation lead times for field retrofits.
The accessory is designed specifically for SACE Tmax XT families and XT5 configurations, offering a 4P AC/DC release rated at 400 A with a setting range of 280–400 A. Its loose or configurable option and front-terminal design support straightforward integration into XT5-based panels and existing Tmax XT installations.
Key certifications include UL489 for circuit-breaker compatibility, CE conformity for European markets, and RoHS/REACH declarations for restricted substances. TSCA, CMRT and other declarations further support global production and compliance, reducing regulatory risk and enabling smoother cross-border deployment.
Although the upfront cost is modest, benefits come from faster installation, fewer mis-wiring errors, and improved protection coordination. The 1-piece MOQ and standardized packaging simplify inventory management, while compliance with UL489 and RoHS reduces risk of non-compliance penalties and warranty issues during operations.
The device features a four-pole AC/DC release with a rated current of 400 A and a setting range of 280–400 A. It is intended for use with Tmax XT panels and XT5 configurations, and complies with UL489 standards for reliable protection in industrial power distribution.