ABB 1SDA102783R1 Accessory - UL/CSA TMA 600A 4P XT5
Part Number: 1SDA102783R1
Quick Summary
ABB 1SDA102783R1 Accessory provides a four-pole thermomagnetic release for Tmax XT circuit protection in industrial power distribution. Engineers often face misapplied releases and uneven coordination, which can trigger nuisance trips or incomplete protection; this accessory simplifies selection and ensures reliable tripping with the XT5 platform. It is UL/CSA listed with additional RoHS and CE declarations, underscoring compliance across global panels. By matching Tmax XT XT5 requirements, it delivers predictable performance, reduced downtime, and streamlined maintenance. For procurement teams, the integration of this XT5 accessory translates to fewer supplier variances and a more robust protection scheme across critical electrical infrastructure.
Product Information
Extended Description
1SDA102783R1 ABB: THERMOMAGNETIC RELEASE FOUR-POLE IN AC-DC TMA R 500 I3=3000...6000 UL/CSA A FULLY RATED NEUTRAL XT5
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221024556
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1.3 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
179 mm
Package Level 1 Height
179 mm
Package Level 1 Depth / Length
223 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8056221024556
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT5
Suitable for Product Class
SACE Tmax XT
Version
F
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
600 A
Release
TMA
Release Type
TM
Setting Range
420…600 A
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT5-XT6
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature criteria and business impact are aligned to the needs of engineers and procurement specialists. The four-pole thermomagnetic release delivers rapid, reliable overcurrent protection, reducing the risk of arc flash and collateral damage. Business impact: improved system uptime and lower repair costs due to precise current sensing and fast tripping. Application: suitable for SACE Tmax XT series power distribution where a robust XT5 accessory is required. The unit supports an In = 600 A rating with a setting range of 420–600 A, enabling selective coordination in medium- and high-current applications, and it is compatible with AC/DC fault conditions to cover diverse industrial loads. Feature: loose or configurable configuration simplifies on-site adaptation; Business Impact: faster installation and reduced customization costs; Application: retrofit or new builds with Tmax XT. Feature: fixed front-terminal connection enhances reliability and ease of wiring during panel assembly; Business Impact: reduces installation time and minimizes wiring errors; Application: front-access installations in crowded control cabinets. Feature: UL489 standard and CE declaration ensure regulatory alignment; Business Impact: smoother approvals and lower compliance risk; Application: global manufacturing environments with strict electrical codes. Feature: RoHS and REACH declarations support sustainability goals; Business Impact: easier supply chain compliance and reduced environmental risk; Application: eco-conscious data centers and industrial facilities.
Get a Quick Quote for a ABB 1SDA102783R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA102783R1?
Enquire Now
FAQs
Installation should follow the Tmax XT XT5 assembly guidelines. It uses a front-terminal connection for quick wiring and a loose or configurable configuration to fit existing control cabinets. Ensure the unit is mounted in a clean environment, tighten connections to spec, and verify the 420–600 A setting range matches the protection coordination plan for your panel.
This accessory is rated for 600 A In with a setting range of 420–600 A. It supports AC/DC fault conditions, uses a four-pole (4P) configuration, and is designed as a thermomagnetic release compatible with UL489 standards. It is intended for Tmax XT XT5 installations in demanding industrial environments.
Yes, this is an accessory designed for SACE Tmax XT, specifically the XT5 family. It features front-terminal connections for reliable wiring and a fixed or configurable configuration approach that eases retrofit and new installs in crowded ducts or enclosures. Confirm panel space and clearance to accommodate the 4P unit.
The unit carries UL489/CSA compatibility, CE declaration, RoHS compliance, and REACH declarations. This combination supports global panel approvals, improves regulatory alignment in diverse markets, and reduces compliance risk during audits and certifications.
By delivering reliable, fully rated protection with a precise 420–600 A setting, the device minimizes nuisance trips and improves uptime. The robust XT5 compatibility reduces spare-part variety, speeds maintenance cycles, and supports longer panel life with fewer unexpected outages, contributing to a favorable total cost of ownership.