ABB 1SDA102887R1 Accessory - UL/CSA, 3P XT6, Tmax XT

Part Number: 1SDA102887R1
Manufacturer
ABB
Part number
1SDA102887R1

Quick Summary

ABB 1SDA102887R1 is a thermomagnetic release accessory for Tmax XT power distribution systems, enabling reliable protection of 3-pole circuits. In busy panel builds, misalignment between the Tmax XT6 breaker and its release accessory can slow assembly and create wiring errors. UL489 and CSA listings accompany RoHS compliance and CE declarations, simplifying approvals and audits across global sites. Designed for XT6 compatibility, this accessory improves installation efficiency, reduces spare-part counts, and supports predictable maintenance in SACE Tmax XT installations. Its compact form and front-terminal connection streamline field-updates and retrofits for diverse industrial environments.

Product Information

Extended Description

1SDA102887R1 ABB: THERMOMAGNETIC RELEASE THREE-POLE IN AC-DC TMA R 800 I3=1600...8000 UL/CSA XT6
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221025058
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
158 mm
Package Level 1 Height
158 mm
Package Level 1 Depth / Length
188 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8056221025058
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT6
Suitable for Product Class
SACE Tmax XT
Version
F
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
800 A
Release
TMA
Release Type
TM
Setting Range
560…800 A
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT5-XT6
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature → Business Impact → Application: The 3-pole AC/DC thermomagnetic release with a 560–800 A setting range delivers precise protection for high-current distribution circuits, reducing nuisance trips and enabling tighter coordination with the main breaker. This translates to fewer unplanned outages and improved system uptime in manufacturing lines and data centers that rely on Tmax XT6 protection. Application: Use in XT6 panels where 800 A nominal load and accurate protection are required, minimizing downtime and extending component life. Feature → Business Impact → Application: Front-terminal, fixed- or configurable-assembly capability simplifies installation and retrofit projects, cutting commissioning time and enabling rapid changes during expansions. Application: Suitable for field upgrades in upgrading power distribution networks with Tmax XT.

Get a Quick Quote for a ABB 1SDA102887R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA102887R1? Enquire Now

FAQs

This accessory is designed for SACE Tmax XT XT6 installations with three poles. It supports loose or configurable configurations and front-terminal connections, enabling straightforward mounting on 3P breakers. Ensure alignment with the XT6 model and torque specs per the data sheet to avoid misfit or improper release operation during commissioning.
The unit provides a rated current of 800 A with a setting range of 560–800 A and supports AC/DC operation. It conforms to UL489 standards, offering robust short-circuit protection and reduced nuisance trips in high-load Tmax XT panels, which translates to improved reliability for critical industrial loads.
Yes. The accessory carries UL489 and CSA references, with RoHS and REACH declarations, plus a CE declaration where applicable. This combination simplifies audits and ensures regulatory alignment across global production sites, making procurement and compliance easier for multi-site projects.
Absolutely. The 1SDA102887R1 is designed for XT6 compatibility and front-terminal mounting, enabling rapid replacements without removing the main breaker. With a weight of about 1 kg and packaging for single-piece shipments, maintenance crews can minimize downtime and streamline spare parts management.
Refer to the SACE Tmax XT UL/CSA data sheets and the release assembly guide for XT5–XT6. Documentation covers wiring diagrams, installation steps, and specification sheets to support safe, compliant retrofits and new builds. Additionally, the packaging includes EAN 8056221025058 for streamlined ordering and traceability.