ABB 1SDA104938R1 Accessory for Tmax XT - IEC60947-2 UL489
Part Number: 1SDA104938R1
Quick Summary
ABB 1SDA104938R1 is a shunt-release accessory for Tmax XT6 withdrawable circuit breakers. In busy control rooms, wiring mistakes and delayed remote signaling can compromise safety and uptime. The unit is CE-marked, UL489-listed, and IEC60947-2 compliant, with RoHS and REACH declarations supporting global compliance. It accepts 110-240 VAC or 110-250 VDC, and its loose or configurable mounting on the XT6 simplifies installation and serviceability. Weighing 0.17 kg with compact packaging, it helps minimize spare parts, reduce commissioning time, and lower total cost of ownership for panel builders and maintenance teams.
Product Information
Extended Description
1SDA104938R1 ABB: YO-C XT6 W 110..240 Vac - 110..250 Vdc
Environmental Product Declaration - EPD
EPD Shunt opening releases Tmax XT XT5-XT6 (IT)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
KXT6YOCWD
E-Number (Finland)
3642168
E-Number (Norway)
4381344
EAN
8015644070304
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.17 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
60 mm
Package Level 1 Depth / Length
140 mm
Package Level 1 Gross Weight
0.2 kg
Package Level 1 EAN
8015644070304
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT6
Suitable for Product Class
SACE Tamx XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Order Multiple
1 piece
Rated Voltage (Ur)
110...240 V AC | 110...250 V DC
Standards
IEC60947-2 | UL489
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
YO - Right side - wired opening release, for XT5 - XT6 withdrawable circuit-breakers.
ETIM 8
EC002483 - Switch spool for power circuit breaker
ETIM 9
EC002483 - Switch spool for power circuit breaker
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
UNSPSC
39121601
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370421
Feature: Wide voltage range (110-240 VAC / 110-250 VDC) plus AC/DC operation. Business Impact: Enables universal compatibility across plant power architectures, reducing inventory of voltage-specific releases. Application: Fits XT6 installations in mixed electrical environments, improving installation efficiency and reliability. Long-tail keywords: XT6 shunt release, Tmax XT accessories, dual voltage shunt release. Feature: Loose or configurable configuration. Business Impact: Flexible mounting and wiring options cut on-site wiring time and error rates. Application: Right-side wired opening release installation on Tmax XT breakers, accelerating commissioning. Long-tail keywords: configurable shunt release, xt6 right-side wiring. Feature: Strong compliance portfolio. Business Impact: Regulatory adherence lowers risk of non-conformance in audits and maintenance, streamlining procurement. Application: IEC60947-2 and UL489-ready for global panels; RoHS/REACH declarations support sustainable sourcing. Long-tail keywords: RoHS Declaration ABB Sace, REACH Declaration, CE conformity. Feature: XT6 compatibility and product lineage. Business Impact: Single accessory covers Tmax XT6 needs, reducing spare parts and procurement complexity. Application: Fits XT6 class breakers, improving inventory management. Long-tail keywords: Tmax XT6 compatibility, XT6 accessories, SACE Tamx XT. Feature: Lightweight and compact packaging. Business Impact: Easier handling and lower shipping costs, improving logistics and ROI. Application: 0.17 kg net weight; box-level packaging 110x60x140 mm. Long-tail keywords: compact packaging, 0.17 kg weight, packaging disposal information.
Get a Quick Quote for a ABB 1SDA104938R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA104938R1?
Enquire Now
FAQs
Yes. The accessory is designed specifically as a shunt release for Tmax XT6 withdrawable circuit-breakers and matches the XT6 form-factor. It supports loose or configurable mounting, enabling straightforward integration on existing XT6 installations without requiring major panel modifications.
The device operates across 110-240 VAC and 110-250 VDC, making it suitable for mixed plant environments. It is compatible with AC/DC current types and is intended for use with Tmax XT6 as a compliant shunt release accessory.
The release is IEC 60947-2 and UL 489 compliant, CE-marked, with RoHS and REACH declarations. Additional documentation includes CMRT and TSCA where applicable, ensuring broad regulatory acceptance and responsible supply-chain data.
The right-side wired design and XT6 compatibility reduce wiring errors and commissioning time. With a compact 0.17 kg footprint and minimal packaging, logistics are simplified, lowering installation costs and reducing downtime during upgrades or expansions.
Minimum order quantity is 1 piece, with Order Code US and Canada KXT6YOCWD and EAN 8015644070304. Documentation includes the data sheet for Tmax XT and related installation manuals, enabling quick, compliant procurement and on-site setup.