ABB 1SDA113098R1 Moulded Case Breaker - Front terminals
Part Number: 1SDA113098R1
Quick Summary
ABB 1SDA113098R1 Moulded Case Breaker is a front-terminal, three-pole protection device designed for medium to high-power switchgear in industrial plants. Engineers often struggle with bulky front-terminal connections, reliable tripping under heavy loads, and minimizing equipment downtime. This model ships with CE conformity, RoHS compliance, and CMRT reporting to support regulatory programs. Its front-terminal design simplifies installation and maintenance in tight enclosures, and it's compatible with ABB SACE Tmax XT lineups for scalable protection. Together these features translate to faster commissioning, reduced field service costs, and improved system reliability for industrial plants. Customers gain predictable performance across varying loads and mission-critical cycles.
Product Information
Extended Description
1SDA113098R1 ABB: C.BREAKER TMAX T5S 630 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 500 I3=2500...5000 A SPECIAL VERSION FOR NUCLEAR EPR
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221031097
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140.0 mm
Product Net Height
205.0 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
4.8 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
4.8 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Version
F
Terminal Connection Type
Front
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT5
Instructions and Manuals
Installation instructions Tmax T5 | F - Front terminals T4-T5 Rc B Type fixed
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: Front-terminal, three-pole construction with a thermal-magnetic release (TMA). Business Impact: Simplified wiring, reduced panel footprint, and faster maintenance while delivering fast, selective protection during overloads and short circuits. Application: Ideal for modular switchgear and transformer protection in industrial facilities where space and protection reliability matter. Feature: Tmax XT compatibility with a T5S 630 frame for robust protection and scalable coordination. Business Impact: Standardized protection across plants reduces design risk, accelerates commissioning, and streamlines spare-part provisioning. Application: Retrofit or new installations within the Tmax XT ecosystem for consistent protection strategies. Feature: Compliance and environmental data including REACH, RoHS, CMRT, TSCA, and CE declarations. Business Impact: Eases global procurement, audits, and supplier qualification while aligning with environmental programs. Application: Global manufacturing, energy, and data-center projects requiring traceable supplier compliance. Feature: Physical footprint and handling advantages with 140 mm width, 205 mm height, 103.5 mm depth, and 4.8 kg weight, plus front-terminal access. Business Impact: Enables installation in crowded panels, simplifies service routines, and reduces installation time and risk. Application: Control cabinets, switchgear assemblies, and protection enclosures across multiple industries. Feature: Special nuclear-grade variant for demanding EPR environments. Business Impact: Supports high-integrity safety systems, regulatory alignment, and traceability for critical infrastructure. Application: Nuclear power, petrochemical facilities, and other high-stakes industries requiring Tmax XT protection with global support.
Get a Quick Quote for a ABB 1SDA113098R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA113098R1?
Enquire Now
FAQs
Start by verifying panel space for the 140 mm width and 103.5 mm depth. Mount the unit using the front-terminal connections, ensure secure torque on terminal screws per the Tmax T5/T5S guidelines, and route conductors for easy access. Check the I3 current range (2500–5000 A) to confirm protection coordination with upstream devices, then test under simulated fault conditions to verify correct tripping.
Key specs include a front-terminal, three-pole design with a thermal-magnetic release (TMA) and an I3 current range from 2500 to 5000 A. It belongs to the Tmax XT family with a T5S 630 frame, delivering reliable short-circuit protection and selective tripping across industrial loads, suitable for transformer and switchgear protection in demanding environments.
Yes. The 1SDA113098R1 is designed for the SACE Tmax XT platform, offering tight coordination with XT protection schemes, a fixed 3P configuration, and front-terminal access that simplifies installation in transformer protection schemes across industrial plants.
The unit features CE conformity, RoHS compliance, and CMRT reporting. Additional declarations include REACH information and TSCA declarations, supporting regulatory compliance and supplier qualification for multinational deployments.
Front-terminal access reduces maintenance time and wiring complexity, while standardized Tmax XT compatibility minimizes design risk. The robust TMA release improves reliability, lowering downtime costs and extending mean time between failures (MTBF); global availability and documentation streamline procurement and field service across sites.