ABB 1SDA116247R1 Moulded Case Circuit Breaker - 8 kV
Part Number: 1SDA116249R1
Quick Summary
ABB 1SDA116247R1 Moulded Case Circuit Breaker protects power distribution panels. This compact, four-pole device delivers reliable overcurrent protection with a front-terminal connection and a thermomagnetic release for fast, predictable trips. Engineers often face nuisance tripping and challenging wiring in tight enclosures; this MCCB addresses those pain points by providing front terminals and a secure TM release. The product is documented under IEC standards and carries RoHS and REACH declarations, plus CMRT and TSCA reporting for supply-chain transparency. By specifying ABB SACE FORMULA DSP in your panels, you gain improved selectivity, easier maintenance, and reduced total cost of ownership through lower downtime and streamlined spare parts inventories.
Product Information
Extended Description
1SDA116249R1 ABB: C.BREAKER FORMULA DSP P1C 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 125-1250 A FULLY RATED NEUTRAL
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221083577
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.3 kg
Package Level 1 Units
1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8056221083577
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P1
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
10.70 W
Rated Current (In)
125 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1250 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
87.5…125 A
Short-Circuit Performance Level
C
Standards
IEC
Sub-type
P1
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Four-pole design with TM release provides coordinated protection across all phases, reducing nuisance trips and enabling precise fault isolation. This supports higher uptime in automated lines and minimizes the impact of faults on downstream equipment. Front-terminal connection simplifies wiring and enables cleaner, more reliable terminations in crowded panels, shortening installation times and reducing field wiring errors. The 87.5–125 A setting range with a 125 A rated current allows tailored protection and better coordination with upstream devices, helping to minimize unnecessary outages while maintaining safety margins. High short-circuit capability across voltage levels ensures robust protection in mixed-power systems, with Ics up to 40 kA at 240 V and up to 25 kA at higher voltages, providing predictable performance during faults. RoHS/REACH declarations, CMRT, and TSCA support meet global regulatory expectations, reducing compliance risk and simplifying supplier audits. The compact footprint (101.6 mm width, 70 mm depth, 130 mm height) and front-terminal design fit standard MCCB mounting frames and enable quick retrofits in existing panels, contributing to lower installation costs and easier maintenance. Mechanical durability of 20,000 cycles and a 10.70 W power loss rating translate to long service life in demanding environments, lowering total cost of ownership and downtime for critical processes. Overall, the ABB SACE FORMULA DSP family delivers dependable protection for power distribution with easier maintenance, streamlined spares, and strong regulatory alignment in industrial automation settings.
Get a Quick Quote for a ABB 1SDA116249R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA116249R1?
Enquire Now
FAQs
Begin with the panel designed for four-pole MCCBs and verify the mounting frame matches the 4P footprint. Mount the unit, connect wiring to the front terminals, and secure mechanical connectors. Set the current to the needed protection level within the 87.5–125 A range, then test the thermomagnetic release and perform a functional trip test to confirm proper operation.
Key ratings include a rated current of 125 A, setting range 87.5–125 A, rated impulse withstand voltage of 8 kV, and rated operational voltage of 500 V AC / 250 V DC. It supports 50/60 Hz, with 4 poles and a 4P configuration. Short-circuit ratings vary by voltage, with Ics up to 40 kA at 240 V and up to 25 kA at higher voltages.
Yes, ABB 1SDA116247R1 is designed for use with P1 distributions and is labeled with the Product Main Type SACE FORMULA DSP. The current setting range is 87.5–125 A, which allows you to tailor protection to your load profile by selecting a setting near the lower end of the range for sensitive feeders or toward the upper end for higher fault thresholds.
The device includes RoHS and REACH declarations, CMRT for Conflict Minerals, and a TSCA declaration. It also aligns with IEC standards, and WEEE packaging information is provided. These declarations support regulatory compliance, sustainability reporting, and responsible supply-chain management across global operations.
With a mechanical durability rating of 20,000 cycles and a modest power loss of 10.70 W, the 1SDA116247R1 offers long service life with lower energy waste. Front-terminal wiring simplifies ongoing inspections, and the modular DSP design reduces downtime during replacements or expansions, contributing to lower maintenance costs and improved ROI in continuous-operation facilities.