ABB 1SDA116293R1 4P MCCB - Moulded Case, 80A, IEC Certified

Part Number: 1SDA116293R1
Manufacturer
ABB
Part number
1SDA116293R1

Quick Summary

ABB 1SDA116293R1 MCCB provides reliable overcurrent protection for industrial power distribution panels and machine systems. In high-density control cabinets, space, wiring complexity, and maintainability are ongoing challenges; this device addresses them with a compact 4-pole front-terminal design and clear labeling. The unit is IEC-certified and supports RoHS and REACH compliance, with CMRT and TSCA declarations for responsible sourcing. It is rated for 80 A, with a setting range of 56–80 A, and offers robust short-circuit performance across 240–500 V AC/DC contexts. This combination of safety, compliance, and reliability translates into reduced downtime, easier maintenance, and predictable life-cycle costs for panel builders and end users. It also complements SACE FORMULA DSP protection suites for P1 applications.

Product Information

Extended Description

1SDA116293R1 ABB: P1S 160 TMD 80-800 4p F F
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084017
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.3 kg
Package Level 1 Units
1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8056221084017
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P1
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
4.80 W
Rated Current (In)
80 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 25 kA | (500 V AC) 4 kA | (250 V DC) 2 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
56…80 A
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
P1
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 4-pole 80 A MCCB with a setting range of 56–80 A enables precise overcurrent protection, reducing nuisance tripping while ensuring upstream equipment is safeguarded. This translates to improved equipment uptime and predictable maintenance windows in manufacturing lines using P1 distribution. Application: Ideal for power distribution panels in industrial facilities where reliability and coordination with SACE FORMULA DSP are critical. Feature → Business Impact → Application: Front-terminal connection simplifies wiring and reduces installation time, improving panel wiring density and serviceability in compact control cabinets. Application: Suitable for retrofit projects and new builds where fast, mess-free wiring is essential. Feature → Business Impact → Application: High Ics (80 kA at 240 V AC) and Icu (50 kA at 380–440 V AC) ratings provide robust fault tolerance, helping facilities meet strict safety standards and minimize downtime during fault events. Application: Critical in heavy-load machinery and critical power feeds. Feature → Business Impact → Application: RoHS, REACH, CMRT, and TSCA declarations enforce regulatory compliance and responsible sourcing. Application: Required for OEMs and end-users with sustainability goals and supplier due-diligence requirements. Feature → Business Impact → Application: Compact dimensions (101.6 mm W, 130 mm H, 70 mm D) and weight (1.3 kg) enable easier enclosure fitment and logistics optimization. Application: Fits standard panels and minimizes rework in constrained spaces. Feature → Business Impact → Application: Power loss of 4.8 W supports energy-conscious design in continuous operation environments. Application: Suitable for continuous protection in energy-intensive processes while managing thermal performance.

Get a Quick Quote for a ABB 1SDA116293R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116293R1? Enquire Now