ABB 1SDA116328R1 Moulded Case Circuit Breaker - 4P 160A 40kA

Part Number: 1SDA116328R1
Manufacturer
ABB
Part number
1SDA116328R1

Quick Summary

ABB 1SDA116328R1 is a moulded case circuit breaker designed to protect power distribution panels in industrial environments. Engineers face the challenge of delivering reliable overload protection while matching space, maintenance, and compliance requirements in modern automation plants. This device meets IEC standards and provides RoHS and REACH declarations, plus CMRT and TSCA reporting to streamline regulatory audits. In practice, you gain reliable overload protection, scalable settings, and safe front-connection installation for P2-based power distribution. Its 4-pole design supports balanced protection for three-phase systems with neutral. The product is designed for simple replacement and minimal downtime. With ABB SACE DSP heritage, it integrates into modern automation architectures.

Product Information

Extended Description

1SDA116328R1 ABB: P2C 250 TMD 160-1600 4p F F InN=50%
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084369
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
8056221084369
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
7.90 W
Rated Current (In)
160 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
112…160 A
Short-Circuit Performance Level
C
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → 4-pole design provides balanced protection across three-phase systems with neutral, reducing wiring complexity and enhancing panel reliability. Business Impact → Improves fault discrimination and reduces nuisance trips in demanding automation lines. Application → Industrial control panels and plant distribution where compact, coordinated protection is essential. Feature → Adjustable Setting Range of 112–160 A enables precise coordination with upstream protection and motor loads. Business Impact → Minimizes downtime and avoids oversizing, cutting energy waste and maintenance costs. Application → Servo drives and conveyors with variable loads in manufacturing. Feature → High short-circuit capacity and robust instantaneous trip behavior (Ics up to 40 kA at 240 V; up to 25 kA at higher voltages) combined with Icu values for diverse supply conditions. Business Impact → Enhanced safety margins and reduced risk of equipment damage under fault conditions. Application → Large drives and bulk power feeders in automation plants. Feature → Low power loss (7.90 W) and mechanical durability up to 20,000 cycles increase operating efficiency and lifecycle cost savings. Business Impact → Lower heat in cabinets, longer service intervals, and reduced cooling requirements. Application → Continuous operation environments with high switching activity. Feature → Front-terminal connection and compact footprint (Product Net Width 140 mm, Height 150 mm, Depth 70 mm) streamline installation and maintenance. Business Impact → Faster wiring, easier retrofits, and reduced panel depth usage. Application → Retrofit projects and new installations in compact control enclosures. Feature → Compliance and documentation (RoHS, REACH, CMRT, TSCA) supports customer audit readiness and corporate sustainability goals. Business Impact → Quicker approvals, smoother supply chain interactions, and lower compliance risk. Application → Global manufacturing facilities seeking standardized, regulator-aligned MCCBs.

Get a Quick Quote for a ABB 1SDA116328R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116328R1? Enquire Now