ABB 1SDA116330R1 Moulded Case Circuit Breaker - 40 kA

Part Number: 1SDA116330R1
Manufacturer
ABB
Part number
1SDA116330R1

Quick Summary

ABB 1SDA116330R1 Moulded Case Circuit Breaker provides reliable protection for power distribution in industrial automation environments. This 4-pole device is rated at 250 A and supports 50/60 Hz systems, helping prevent nuisance trips while enabling precise fault isolation. The TM release with a 175–250 A setting range offers fast response during short-circuit events, and the front-terminal design simplifies retrofit and commissioning. With IEC standards compliance and RoHS, REACH, CMRT declarations, it aligns with global regulatory requirements. Designed for P2 power distribution, this MCCB delivers robust safety, easy maintenance, and predictable lifecycle costs, making it a strong foundation for scalable control panels and motor-drive applications.

Product Information

Extended Description

1SDA116330R1 ABB: P2C 250 TMD 250-2500 4p F F InN=50%
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084383
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
8056221084383
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
17.80 W
Rated Current (In)
250 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
2500 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
175…250 A
Short-Circuit Performance Level
C
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → 4P, 250 A, 50/60 Hz operation → Business Impact → Ensures consistent protection for feeders and reduces nuisance tripping during motor start-ups, enabling smoother production lines. Application → Suitable for power distribution panels and motor control centers that demand reliable isolation of four-phase loads. Feature → High fault current withstand and voltage ratings (Ics up to 40 kA at 240 V AC; Icu up to 25 kA at higher voltages; Ui 750 V; Ur 500 V) → Business Impact → Increases system safety margins and selectivity in heavy-load environments, reducing the risk of downstream damage. Application → Ideal for panel boards feeding heavy motors and cranes in manufacturing facilities. Feature → Configurable protection with 175–250 A setting range and TM release → Business Impact → Tailors protection to feeder sections, improves coordination, and minimizes unnecessary trips. Application → Aligns with P2 protection schemes in SACE FORMULA DSP MCCBs used in distribution networks. Feature → Front-terminal connection, compact footprint, and 20,000 mechanical cycles; power loss 17.80 W → Business Impact → Facilitates fast installation, predictable thermal behavior, and lower cooling requirements, boosting uptime. Application → Retrofit and new installations in space-constrained control panels and switchgear. Feature → Compliance commitments (RoHS, REACH, CMRT, TSCA) and WEEE guidance → Business Impact → Simplifies regulatory clearance and sustainability reporting, reducing audit overhead. Application → Global manufacturing and export environments targeting EU, US, and other regions.

Get a Quick Quote for a ABB 1SDA116330R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116330R1? Enquire Now