ABB 1SDA116336R1 Moulded Case Circuit Breaker - 8 kV
Part Number: 1SDA116336R1
Quick Summary
ABB 1SDA116336R1 is a moulded case circuit breaker designed for 3-phase power distribution in industrial control panels. Engineers rely on reliable overcurrent protection that adapts to P2N 250 TMD 160-1600 settings while minimizing nuisance trips and downtime. This device complies with IEC standards and is RoHS compliant, with REACH, CMRT, and TSCA declarations supporting global supply chains. In practice, it delivers predictable protection, straightforward installation, and long-term reliability, helping original equipment manufacturers and panel builders meet safety requirements and reduce maintenance costs in automation and process environments. When selecting protection for ABB SACE FORMULA DSP offerings, this MCCB provides a robust, standards-based solution for efficient power distribution.
Product Information
Extended Description
1SDA116336R1 ABB: P2N 250 TMD 160-1600 3p F F
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084444
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.6 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
1.7 kg
Package Level 1 EAN
8056221084444
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
7.90 W
Rated Current (In)
160 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
112…160 A
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 3P design with a 160 A In rating enables precise, predictable protection for multi-phase power circuits, reducing nuisance trips and extending equipment life in control panels and machine rooms. This directly supports uptime and process stability in manufacturing lines where downtime is costly and reliability is paramount. Feature → Business Impact → Application: Adjustable Setting Range of 112–160 A allows tailoring protection to evolving load profiles, lowering the risk of undersized protection while preventing unnecessary trips during startup or peak demand in automation systems. Feature → Business Impact → Application: Short-circuit capacities (Ics up to 50 kA at 240 V, 36 kA at higher voltages; Icu up to 50 kA at 240 V, 36 kA at higher voltages) provide robust fault handling for high-inrush equipment and rapid isolation, boosting safety in power distribution boards. Feature → Business Impact → Application: Front terminal connections enable fast, secure wiring in tight enclosures, simplifying installation and reducing commissioning time across panel builds. Feature → Business Impact → Application: Power loss of 7.90 W and 20,000 mechanical cycles translate to lower operating costs and longer service life for continuous-duty protection in process automation. Feature → Business Impact → Application: RoHS, REACH, CMRT, and TSCA declarations unify global compliance, easing cross-border procurement for OEMs and integrators. Feature → Business Impact → Application: Compatibility with the SACE FORMULA DSP family ensures seamless integration into ABB protection schemes, improving spare parts standardization and maintenance planning in industrial automation environments.
Get a Quick Quote for a ABB 1SDA116336R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA116336R1?
Enquire Now