ABB 1SDA116340R1 Moulded Case Circuit Breaker - 4P - 50kA

Part Number: 1SDA116340R1
Manufacturer
ABB
Part number
1SDA116340R1

Quick Summary

ABB 1SDA116340R1 is a high-performance Moulded Case Circuit Breaker designed for robust power distribution protection in industrial environments. Engineers often struggle to balance fast fault clearance, durability, and regulatory compliance in demanding applications. This device aligns with IEC standards and offers RoHS and REACH declarations, with CMRT and TSCA information available for global supply chains. In practice, it enables reliable P2 protection in distribution panels while simplifying installation and maintenance, delivering tangible business value through reduced downtime, consistent performance, and easier compliance reporting.

Product Information

Extended Description

1SDA116340R1 ABB: P2N 250 TMD 160-1600 4p F F InN=50%
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084482
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
8056221084482
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
7.90 W
Rated Current (In)
160 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
112…160 A
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: 4-pole configuration with front-terminal connections improves multi-phase protection and simplifies physical installation, reducing wiring errors and panel assembly time in automation cabinets. Application: ideal for P2 protection in switchgear and distribution boards where space efficiency and reliable disconnects are critical. Feature → Business Impact → Application: Rated current of 160 A and 500 V AC / 250 V DC capability enables direct protection of common industrial feeders, lowering the need for oversized alternative devices. Application: suitable for motor control centers and distribution panels in manufacturing lines. Feature → Business Impact → Application: Setting range 112–160 A provides field-tunable protection without device swaps, enabling precise coordination with upstream protection schemes. Application: supports customized protection in evolving plant architectures. Feature → Business Impact → Application: High Ics (up to 50 kA at 240 V AC) and Ii (1600 A) deliver robust short-circuit resilience, reducing downtime during faults. Application: critical for high-demand feeders and critical loads. Feature → Business Impact → Application: 4P compact form in the SACE FORMULA DSP family offers consistent product lifecycle and spare-part availability, cutting total cost of ownership. Application: preferred choice for OEMs and system integrators focusing on long-term reliability. Feature → Business Impact → Application: RoHS/REACH and CMRT declarations ensure regulatory compliance across regions, easing procurement and customer audits. Application: essential for global projects with strict material and supplier transparency requirements.

Get a Quick Quote for a ABB 1SDA116340R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116340R1? Enquire Now

FAQs

Yes. The ABB 1SDA116340R1 uses a front-terminal connection and is designed for standard MCCB mounting footprints in industrial distribution boards. Verify enclosure dimensions to ensure proper fit, but the 4P format and 140 x 150 x 70 mm net dimensions support common DIN-rail or panel-mount configurations in P2 protection applications.
Key ratings include 4-pole configuration, 160 A rated current, 500 V AC / 250 V DC, setting range 112–160 A, Ii up to 1600 A, and Ics up to 50 kA (240 V AC). The device supports 50/60 Hz operation and IEC standards, delivering reliable fault interruption across typical industrial feeders.
Ideal for power distribution in manufacturing lines, process industries, and automation panels requiring robust short-circuit protection (Ics) and precise coordination with upstream devices. Its 4P design and front-terminal layout streamline protection of multi-phase feeders and critical loads in distribution boards.
This MCCB aligns with IEC standards and includes RoHS and REACH declarations, CMRT (Conflict Minerals Reporting Template), and TSCA compliance information. WEEE categorization and packaging/disposal guidance are provided to support audits and sustainability programs.
With a mechanical durability of up to 20,000 cycles and low power loss (7.90 W), the device offers long service life and reduced energy waste. Front-terminal installation speeds commissioning, while regulatory declarations simplify compliance. Overall, expect lower downtime, predictable protection, and improved total cost of ownership in high-demand facilities.