ABB 1SDA116356R1 Moulded Case Circuit Breaker - 8 kV
Part Number: 1SDA116356R1
Quick Summary
ABB 1SDA116356R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial power distribution panels. Engineers seek devices that balance safety, coordination, and lifecycle cost in demanding environments, and this model delivers. It carries IEC-based compliance with RoHS and REACH declarations alongside CMRT and TSCA documentation for regulated markets. With a 4-pole configuration, 160 A rating, and front-terminal installation, it simplifies panel design while meeting P2 protection needs. As part of the SACE FORMULA DSP lineage, it supports streamlined maintenance, faster commissioning, and consistent performance across industrial automation applications.
Product Information
Extended Description
1SDA116356R1 ABB: P2S 250 TMD 160-1600 4p F F InN=100%
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084642
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
8056221084642
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
7.90 W
Rated Current (In)
160 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 20 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 6 kA | (250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
112…160 A
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 4P design with a 160 A rated current enables robust phase protection for three-phase power distribution, reducing the risk of cascading faults and unplanned downtime in manufacturing lines. This translates to improved line availability and lower maintenance costs in industrial panels and machine centers. Feature → Business Impact → Application: Ui of 750 V (Rated Insulation Voltage) provides a broad safety margin for mixed-voltage installations, enabling safer wiring and simplified panel layouts in control cabinets and subpanels. Feature → Business Impact → Application: Rated Operational Voltage of 500 VAC / 250 V DC and a setting range of 112–160 A offer easy coordination with upstream protective devices, helping engineers fine-tune trip characteristics for motors and drives in packaging, material handling, and process lines. Feature → Business Impact → Application: High Ics (up to 50 kA at 240 V AC) and Icu (up to 80 kA at 240 V AC) provide strong short-circuit resilience, minimizing equipment damage and service interruptions in high-energy applications like conveyors and feeders. Feature → Business Impact → Application: Front terminal connections simplify field wiring and reduce install time, lowering labor costs and improving reliability in tight panel spaces and compact switchgear. Feature → Business Impact → Application: RoHS/REACH declarations, CMRT, and TSCA compliance mitigate regulatory risk, support global procurement, and accelerate supplier audits for aerospace, automotive, and heavy industry sites. Feature → Business Impact → Application: Mechanical durability of 20,000 cycles and a power loss of 7.90 W offer predictable long-term performance with lower operating costs, ideal for high-switching environments such as stamping presses and CNC machinery. Feature → Business Impact → Application: Product compatibility with the P2 protection style and the SACE FORMULA DSP family ensures consistent protection across modern automation architectures, enabling scalable panel strategies and easier upgrades.
Get a Quick Quote for a ABB 1SDA116356R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA116356R1?
Enquire Now