ABB 1SDA116358R1 Moulded Case Circuit Breaker - 8 kV

Part Number: 1SDA116358R1
Manufacturer
ABB
Part number
1SDA116358R1

Quick Summary

ABB 1SDA116358R1 is a moulded case circuit breaker designed to protect P2 power distribution networks in industrial facilities. It delivers reliable fault interruption and scalable protection for complex electrical assemblies, reducing downtime in critical processes. This device complies with IEC standards and carries RoHS and REACH declarations, along with CMRT and TSCA documentation to support global sourcing and compliance. With front-terminal installation, 4-pole configuration, and a 250 A rating, it provides a robust platform for safe startup, maintenance, and long-term operational integrity while enabling cost-effective expansion of power distribution assets in manufacturing plants.

Product Information

Extended Description

1SDA116358R1 ABB: P2S 250 TMD 250-2500 4p F F InN=100%
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084666
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
2 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
8056221084666
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
17.80 W
Rated Current (In)
250 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
2500 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 20 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 40 kA | (500 V AC) 6 kA | (250 V DC) 2 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
175…250 A
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 4P design and 250 A rated current enable direct integration into standard P2 power distribution panels, providing precise protection for multi-phase loads and straightforward coordination with other protective devices. Business Impact: enhances system reliability and uptime by preventing cascading faults and enabling predictable segmentation of circuits. Application: ideal for industrial power distribution in manufacturing lines and data centers seeking scalable protection and easy retrofit into existing P2 boards. Feature: 8 kV impulse withstand improves surge protection in environments with transients and switching spikes. Business Impact: reduces risk of equipment damage during lightning events or switching transients, safeguarding critical loads. Application: suitable for harsh plant environments and coastal facilities where transient events are common. Feature: High short-circuit ratings (Ics up to 50 kA at 240 V AC; 36 kA at higher AC voltages) allow fast, dependable interruption. Business Impact: minimized fault energy and faster isolation preserves equipment life and worker safety. Application: protects motors and feeders in heavy-duty automation lines. Feature: Adjustable Setting Range (175–250 A) provides flexible coordination with upstream protection and downstream devices. Business Impact: reduces over- or under-protection, optimizing energy use and maintenance cycles. Application: adjustable for evolving load profiles in P2 distributions and modular panel builds. Feature: Low power loss (17.80 W) with compact 140 × 150 × 70 mm footprint improves thermal management and cabinet density. Business Impact: lowers operating heat and fan requirements, cutting energy and cooling costs. Application: high-density switchgear where space and cooling are critical. Feature: Front terminal connection simplifies wiring and retrofit installation. Business Impact: speeds up commissioning and replacement, minimizing downtime. Application: rapid upgrades in legacy switchboards and modular assemblies. Feature: 20,000 mechanical cycles ensure long service life in frequent operation scenarios. Business Impact: reduces maintenance costs and unplanned downtime. Application: production lines with high interlock and restart cycles. Feature: Compliance and declarations (ROHS, REACH, CMRT, TSCA) support global sourcing and regulatory readiness. Business Impact: streamlines supplier qualification and cross-border procurement. Application: multinational facilities requiring robust environmental and material compliance.

Get a Quick Quote for a ABB 1SDA116358R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116358R1? Enquire Now

FAQs

Yes. This 4-pole moulded case circuit breaker is designed for P2 power distribution and uses front-terminal connections to simplify wiring, reduce installation time, and improve serviceability in existing panels. Its compact dimensions (140 mm wide, 150 mm high, 70 mm deep) support retrofit into standard switchgear cabinets and modular installations.
The device features a setting range of 175–250 A with a specified instantaneous short-circuit current setting Ii of 2500 A. Its service short-circuit breaking capacity Ics varies by voltage (up to 50 kA at 240 V AC and 36 kA at higher AC voltages), and ultimate breaking capacity Icu reaches up to 50 kA at 240 V AC. These ratings enable fast, selective protection for multi-phase circuits.
Yes. The 4P 250 A MCCB is suitable for power distribution including motor feeders within P2 networks. Its release options (TMD, TM) and setting range support motor protection schemes, while the 500 V AC / 250 V DC operating range accommodates diverse drive and control architectures. Ensure coordination with upstream protection and motor starters for optimal protection.
The product includes IEC standards compliance along with material declarations such as RoHS Information, REACH Declaration, and CMRT (Conflict Minerals Reporting Template). TSCA declaration and environmental packaging information are also available, supporting global procurement and regulatory requirements.
With 20,000 mechanical durability cycles and a compact, low-heat design (17.80 W power loss), the MCCB reduces maintenance intervals and cooling requirements, preserving uptime and lowering total cost of ownership. The front-terminal design also speeds replacement, decreasing downtime during upgrades or servicing.