ABB 1SDA116362R1 Moulded Case Circuit Breaker 3P 250A - IEC

Part Number: 1SDA116362R1
Manufacturer
ABB
Part number
1SDA116362R1

Quick Summary

1SDA116362R1 is a moulded case circuit breaker for power distribution protection in industrial control panels. Engineers often struggle with selecting MCCBs that deliver reliable short-circuit protection while fitting into compact, crowded switchboards. This ABB SACE device carries IEC compliance along with explicit RoHS/REACH declarations and TSCA/CMRT documentation, supporting global sourcing and risk management. With a 3P 250 A rating and front-terminal installation, it helps reduce maintenance time, simplify wiring, and improve panel space for power distribution and P2 protection schemes. Its robust design and industry-standard trip characteristics empower engineers to meet safety and uptime targets across data centers, manufacturing lines, and process plants.

Product Information

Extended Description

1SDA116362R1 ABB: P2H 250 TMD 250-2500 3p F F
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084703
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.6 kg
Package Level 1 Units
1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
1.7 kg
Package Level 1 EAN
8056221084703
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P2
Version
F
Current Type
AC/DC
Mechanical Durability
20000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
17.80 W
Rated Current (In)
250 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
2500 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 30 kA | (500 V AC) 3 kA | (250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 60 kA | (500 V AC) 8 kA | (250 V DC) 2 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMD
Release Type
TM
Setting Range
175…250 A
Short-Circuit Performance Level
H
Standards
IEC
Sub-type
P2
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
Installation instructions P2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 250 A rated, 3P design provides reliable protection for feeders and motors, improving uptime and reducing nuisance trips in distribution panels. This translates to lower maintenance costs and fewer production interruptions in manufacturing lines that rely on stable feeders. In practical terms, it suits main and sub-feed sections within electrical rooms handling heavy loads and motor-driven equipment. Feature → Business Impact → Application: The adjustable setting range of 175–250 A enables tailored protection for evolving load profiles, reducing over-tripping and enabling faster commissioning in new lines or retrofits. This is particularly valuable for P2 protection schemes and growing data-center rack farms where precise trip characteristics are critical. Feature → Business Impact → Application: High short-circuit capacities (Ics up to 50 kA at 240 V and Icu up to 70 kA) provide margin against peak fault currents, safeguarding switchgear from cascading faults and extending component life in high-energy environments. Feature → Business Impact → Application: Front-terminal connection and compact dimensions (105 mm width, 150 mm height, 70 mm depth) enable faster, safer installation and simpler retrofits in densely packed switchboards, reducing commissioning time and wiring errors. Feature → Business Impact → Application: Comprehensive compliance (IEC standards with RoHS, REACH, CMRT, and TSCA) lowers regulatory risk for multinational projects and simplifies supplier qualification for global procurement. Feature → Business Impact → Application: Real-world reliability metrics (20,000 mechanical cycles, 17.80 W power loss) translate into predictable maintenance intervals and energy efficiency, supporting total cost of ownership reduction across manufacturing and process industries. In summary, this MCCB delivers compatibility with ABB SACE FORMULA DSP panels, proven protection for P2 circuits, and installation advantages that support faster project delivery and ongoing compliance.

Get a Quick Quote for a ABB 1SDA116362R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116362R1? Enquire Now