ABB 1SDA116388R1 Moulded Case Circuit Breaker - 80kA@240V
Part Number: 1SDA116388R1
Quick Summary
ABB 1SDA116388R1 is a high-capacity moulded case circuit breaker for industrial power distribution. In challenging switchgear environments, you need reliable protection with precise tripping to minimize downtime. The unit aligns with IEC standards, and carries RoHS and TSCA declarations, with CMRT for transparent supply chain reporting. With P3 compatibility and SACE FORMULA DSP release, it supports scalable protection in large panels while offering space-efficient installation. The 4-pole design delivers 630 A nominal rating and 8 kV impulse withstand for robust protection across 500 VAC / 250 V DC systems. Front-terminal connection simplifies mounting and wiring, helping engineers reduce assembly time and service costs.
Product Information
Extended Description
1SDA116388R1 ABB: P3S 630 TMA 630-6300 4p F F InN=100%In
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221084963
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
186 mm
Product Net Height
205 mm
Product Net Depth / Length
103 mm
Product Net Weight
5.8 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
5.8 kg
Package Level 1 EAN
8056221084963
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P3
Version
F
Current Type
AC/DC
Mechanical Durability
15000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
47.80 W
Rated Current (In)
630 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
3150…6300 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 18 kA | (250 V DC) 2 Poles in Series 35 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 25 kA | (250 V DC) 2 Poles in Series 35 kA
Rated Uninterrupted Current (Iu)
630 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMA
Release Type
TM
Setting Range
441…630 A
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
P3
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
1SDH002124A1001
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: 4-pole 630 A rating combined with a 441–630 A setting range enables precise short-circuit protection aligned to load profiles, reducing nuisance trips in high-demand panels. Application: distribution boards in process lines and data centers. Feature → Business Impact → Application: Front-terminal connection simplifies wiring and installation, reducing assembly time and enabling easier maintenance access in compact switchgear. Application: new construction and retrofit projects where panel space is at a premium. Feature → Business Impact → Application: Ics/Icu up to 80 kA at 240 V and 8 kV impulse withstand improve fault handling and safety in critical power paths. Application: critical power supply feeders and motor-control centers. Feature → Business Impact → Application: 50/60 Hz operation with RoHS/CMRT/TSCA compliance ensures regulatory alignment and easy procurement. Application: multinational manufacturing sites with strict product stewardship. Feature → Business Impact → Application: 47.80 W power loss and 15,000 mechanical cycles deliver long service life and lower life-cycle costs. Application: high-cycle protection in continuous-process environments. Feature → Business Impact → Application: Dimensions (186 mm W × 205 mm H × 103 mm D) and 5.8 kg weight support compact integration and predictable packaging in standardized enclosures. Application: panel design and BOM planning for control rooms and industrial plants.
Get a Quick Quote for a ABB 1SDA116388R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA116388R1?
Enquire Now
FAQs
ABB 1SDA116388R1 uses front-terminal connections designed for easy panel mounting and wiring. When planning installation, confirm enclosure cutouts align with 186 mm width, 205 mm height, and 103 mm depth, and allow about 5.8 kg of weight per unit. Use proper torque on terminals, ensure adequate clearance for cooling, and follow IEC installation guidelines for safe operation.
Key specifications include a 4-pole configuration, rated current 630 A, rated voltage 500 VAC / 250 V DC, setting range 441–630 A, impulse withstand voltage 8 kV, and short-circuit breaking capacities Ics 80 kA (240 V) and Icu 80 kA (240 V). It operates at 50/60 Hz and uses a TMA release for reliable fault interruption.
Yes. This device is designed for P3 power distribution with SACE FORMULA DSP, offering 4P protection, 630 A nominal current, and high fault-current handling. Its compact front-terminal design and RoHS/TSCA compliance simplify integration into standard control panels and modular switchgear layouts.
The MCCB carries IEC standards compliance, RoHS information, CMRT for conflict minerals reporting, and TSCA declarations. WEEE packaging information is also provided. These certifications ensure regulatory alignment across regions, support responsible sourcing, and facilitate audit-ready documentation for procurement and compliance teams.
High durability (15,000 cycles) and low power loss (47.80 W) reduce maintenance cycles and energy costs, improving uptime in critical lines. The front-terminal design speeds commissioning and servicing, while IEC/compliance declarations simplify warranties and audits. Overall, it lowers lifecycle costs by delivering reliable protection with minimal intervention.