ABB 1SDA116398R1 Moulded Case Circuit Breaker - IEC

Part Number: 1SDA116398R1
Manufacturer
ABB
Part number
1SDA116398R1

Quick Summary

ABB 1SDA116398R1 is a 3-pole moulded case circuit breaker for P4N 800 distribution panels. Engineers often face space constraints, long lead times, and compliance challenges during panel upgrades. It adheres to IEC standards, carries RoHS and REACH declarations, and provides TSCA information for a transparent supply chain. With front-terminal installation and an adjustable 560–800 A setting, it streamlines commissioning and reduces downtime. This ABB device delivers reliable protection while supporting scalable, compliant builds for industrial automation environments.

Product Information

Extended Description

1SDA116398R1 ABB: P4N 800 TMA 800-8000 3p F F
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221085069
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
9.5 kg
Package Level 1 Units
1 piece
Package Level 1 Width
305 mm
Package Level 1 Height
285 mm
Package Level 1 Depth / Length
370 mm
Package Level 1 Gross Weight
9.6 kg
Package Level 1 EAN
8056221085069
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P4
Version
F
Current Type
AC/DC
Mechanical Durability
15000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
54.20 W
Rated Current (In)
800 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
4000…8000 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 30 kA | (500 V AC) 15 kA | (250 V DC) 2 Poles in Series 35 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 30 kA | (500 V AC) 20 kA | (250 V DC) 2 Poles in Series 35 kA
Rated Uninterrupted Current (Iu)
800 A
Rated Voltage (Ur)
500 V AC | 250 V DC
Release
TMA
Release Type
TM
Setting Range
560…800 A
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
P4
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
1SDH002127A1001
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 3P front-terminal design with a 560–800 A setting range. Business Impact: Simplified wiring, safer installation, and precise overload protection to minimize nuisance tripping. Application: Retrofit of existing switchgear and new P4N 800-based panels in factories where quick commissioning matters. Feature: Rated Current (I_n) 800 A and Rated Voltage (U_r) 500 V AC / 250 V DC. Business Impact: Clear coordination with medium-voltage feeders and reliable performance across AC/DC networks. Application: Motor control centers and power distribution blocks in process industries requiring robust, dual-voltage operation. Feature: High fault-current capability with I_cs up to 50 kA (240 V) and I_cu up to 50 kA (240 V). Business Impact: Superior protection during short circuits, reducing arc energy and equipment damage. Application: Heavy-load feeders for press lines and packaging lines where fault currents are unpredictable. Feature: IEC compliance plus RoHS, REACH, and TSCA declarations. Business Impact: Streamlined procurement, lower regulatory risk, and easier supplier audits. Application: Global deployments across North America, Europe, and APAC with strict compliance requirements. Feature: Power loss 54.20 W and 8 kV impulse withstand. Business Impact: Lower thermal stress in continuous operation and enhanced reliability in harsh environments. Application: Continuous-process applications and harsh factory floors where ambient conditions vary. Feature: Product family integration (SACE FORMULA DSP) and data availability (Catalogue PDF and manual). Business Impact: Access to validated engineering data, faster design-in, and improved maintenance planning. Application: New builds and modernizations in industrial automation and power distribution networks.

Get a Quick Quote for a ABB 1SDA116398R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA116398R1? Enquire Now