ABB 1SDA116435R1 Moulded Case Circuit Breaker - 50kA

Part Number: 1SDA116435R1
Manufacturer
ABB
Part number
1SDA116435R1

Quick Summary

ABB 1SDA116435R1 Moulded Case Circuit Breaker provides robust motor protection for industrial power distribution. Engineered for P3 motor protection, it helps protect drives, pumps, and conveyors from damaging short circuits while maintaining process uptime. Operators often struggle with nuisance trips, miscoordination, and regulatory gaps when protection devices lag or are unsuitable for high fault currents. This MCCB line includes REACH Declaration, RoHS compliance, and TSCA information, aligning with IEC standards for safer operation and global deployment. By combining reliable protection with easy installation and clear documentation, it delivers measurable business value through improved safety, reduced downtime, and lower lifecycle costs in modern manufacturing environments.

Product Information

Extended Description

1SDA116435R1 ABB: P3N 630 MA500 Im=3500…6500 3p F F
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8056221085434
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103 mm
Product Net Weight
4.8 kg
Package Level 1 Units
1 piece
Package Level 1 Width
248 mm
Package Level 1 Height
240 mm
Package Level 1 Depth / Length
285 mm
Package Level 1 Gross Weight
4.8 kg
Package Level 1 EAN
8056221085434
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE FORMULA DSP
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
P3
Version
F
Current Type
AC
Mechanical Durability
15000 cycle | 240 cycles per hour
Number of Poles
3P
Rated Current (In)
500 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
3500...6500 A
Rated Insulation Voltage (Ui)
750 V
Rated Operational Voltage
500 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 20 kA
Rated Uninterrupted Current (Iu)
630 A
Rated Voltage (Ur)
500 V AC
Release
MA
Release Type
M
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
P3
Terminal Connection Type
Front
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] FORMULA DSP MCCB
Instructions and Manuals
1SDH002124A1001
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 3-pole design with front-terminal connection supports straightforward retrofit into existing switchgear and control panels, reducing installation time and commissioning risk for panel builders and OEMs in industrial facilities. This translates to faster project delivery and lower labour costs when upgrading motor protection for large drives or pump stations. Feature → Business Impact → Application: Rated current of 500 A and rated voltage of 500 V AC enable reliable protection of high‑power motors in packaging lines, water treatment, and manufacturing lines, while preserving safe disconnects during faults. This supports selective coordination and minimizes unnecessary outages in harsh, high-current environments. Feature → Business Impact → Application: Adjustable instantaneous trip Ii from 3500 to 6500 A with Ics up to 50 kA and Icu up to 20 kA ensures fast fault interruption without cascading trips, improving machine safety and uptime in stamping presses, extrusion lines, and material handling. Feature → Business Impact → Application: RoHS and REACH declarations along with TSCA compliance reduce regulatory risk in global deployments, making this MCCB suitable for cross-border installations and regulated industries such as food and pharmaceuticals where material declarations matter. Feature → Business Impact → Application: Mechanical durability of 15,000 cycles at 240 cycles/hour delivers long service life in high-usage environments, lowering maintenance frequency and replacement cycles for critical power distribution in continuous processes. Feature → Business Impact → Application: 750 V Ui, 500 V Ur, and 8 kV impulse withstand enhance insulation margin and transient protection in panel boards and motor control centers, supporting safer operation in 50/60 Hz networks and challenging electrical environments. Feature → Business Impact → Application: Documentation and EAN (8056221085434) along with a data sheet facilitate procurement, traceability, and compliance reporting for OEMs and energy managers seeking reliable SACE FORMULA DSP MCCB solutions in P3 motor protection schemes.

Get a Quick Quote for a ABB 1SDA116435R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours