ABB 1SDA123508R1 Moulded Case Circuit Breaker - IEC 60947-2

Part Number: 1SDA123508R1
Manufacturer
ABB
Part number
1SDA123508R1

Quick Summary

ABB 1SDA123508R1 is a DC moulded-case circuit breaker designed to protect 500 V DC distribution systems. Engineers encounter challenges with compact panel layouts, front-access wiring, and reliable disconnection under fault conditions. Certified to IEC 60947-2 with CE conformity and GB/T 14028.2, it also aligns with RoHS and REACH as part of ABB EcoSolutions. The fixed four-pole design with front terminals simplifies installation and servicing, while its low power loss and high durability support long-term total cost of ownership. In demanding environments such as data centers, industrial drives, and renewable energy facilities, this breaker delivers predictable coordination and uptime.

Product Information

Extended Description

1SDA123508R1 ABB: C.BREAKER TMAX XT2N 160 DC FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 16
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.7 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Customs Tariff Number
85362000
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
DC
Mechanical Durability
25000 cycle | ;240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 1.33 W
Rated Current (In)
16 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC 60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation instructions XT2 DC IEC
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
DC rated performance with 500 V DC operation and 16 A nominal current provides robust protection for DC distribution panels, reducing nuisance trips and enabling safe fault clearance in critical systems. Front-terminal design and fixed mounting streamline installation in compact enclosures, lowering wiring complexity and service time for panel builders. The thermomagnetic release (TMD TM) delivers fast, selective tripping, improving system uptime and limiting collateral damage during faults. A power loss of 1.33 W per pole supports cooler cabinet temperatures and energy efficiency across the board, while a 25,000-cycle mechanical durability rating ensures long service life in high-cycle applications. EcoSolutions features, including End Of Life disassembly guidance and recyclability considerations, support sustainability goals and regulatory compliance.

Get a Quick Quote for a ABB 1SDA123508R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA123508R1? Enquire Now

FAQs

The ABB 1SDA123508R1 uses a fixed front-terminal configuration for straightforward panel mounting. Ensure the panel provides 500 V DC rating and space for a four-pole device. Verify clearance for front-terminal connection, tighten terminals to the recommended torque, and confirm proper seat and isolation before energizing. The device is designed for quick integration with minimal wiring complexity, reducing commissioning time.
Key specs include a rated current of 16 A, rated insulation voltage of 1000 V, and rated operational voltage of 500 V DC. Short-circuit performance is 36 kA in series for both 250 V DC and 500 V DC configurations, with an impulse withstand voltage of 8 kV. Power loss is 1.33 W per pole, and the unit uses a TM/TMD release for selective tripping.
Yes. Its DC ratings, high short-circuit withstand capability, and front-terminal installation suit data centers, renewable energy storage, and other DC distribution needs. The four-pole, fixed-design supports space-efficient cabinet layouts, while IEC 60947-2 compliance and RoHS/REACH align with industry standards and sustainability goals.
The product conforms to IEC 60947-2 and GB/T 14028.2, with CE labeling. It is documented under ABB EcoSolutions for sustainability programs, including end-of-life disassembly instructions and environmental declarations (EPD). RoHS and REACH declarations are provided, supporting regulatory compliance in multiple markets.
Expect low maintenance due to high mechanical durability (25,000 cycles) and a compact, low-loss design (1.33 W per pole). Its front-terminal access reduces maintenance time and error rates during servicing. Over time, the high reliability and compliance with key standards help reduce downtime, improve panel uptime, and lower total cost of ownership.