ABB 1SDA123515R1 Moulded Case Circuit Breaker - IEC 60947-2
Part Number: 1SDA123515R1
Quick Summary
ABB 1SDA123515R1 is a DC moulded case circuit breaker for industrial power distribution. This device addresses trip reliability and front-terminal wiring challenges common in harsh industrial environments. It aligns with IEC 60947-2, CE declarations, and RoHS compliance to support global applications. Designed for DC distribution and energy efficiency, this MCCB pairs with ABB EcoSolutions for sustainable practices and lifecycle optimization.
Product Information
Extended Description
1SDA123515R1 ABB: C.BREAKER TMAX XT2N 160 DC FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 80
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.7 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Customs Tariff Number
85362000
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
DC
Mechanical Durability
25000 cycle | ;240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 5.8 W
Rated Current (In)
80 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC 60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation instructions XT2 DC IEC
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: DC rated 4P design with 80 A current and 500 V DC operating voltage; Business Impact: ensures robust protection for critical DC networks and minimizes nuisance trips; Application: battery energy storage systems, DC distribution panels, and motor drive interfaces. Feature: Front-terminal fixed mounting for quick wiring and service; Business Impact: reduces installation time and panel depth, lowering downtime; Application: compact switchgear in control cabinets and substations. Feature: Low power loss at rated conditions (5.8 W per pole); Business Impact: improved thermal margins and energy efficiency in continuous operation; Application: high-density DC protection in space-constrained enclosures. Feature: Compliance and end-of-life data (IEC 60947-2, RoHS, REACH, EPD); Business Impact: simplifies regulatory approvals and sustainable disposal; Application: global manufacturing and green initiatives. Feature: 25,000 mechanical cycles durability; Business Impact: extended service life and reduced maintenance costs; Application: heavy-duty industrial protection in demanding environments.
Get a Quick Quote for a ABB 1SDA123515R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA123515R1?
Enquire Now
FAQs
Install the 4P MCCB with front terminals in the panel using standard DIN rail or panel mounting practices. Ensure proper torque on terminals, align with the 120 mm width and 130 mm height enclosure, and verify insulation with a 1000 V rating. The front-terminal design simplifies wiring, reduces installation time, and improves serviceability during maintenance.
Key specs include a rated current of 80 A, rated insulation voltage of 1000 V, rated operational voltage of 500 V DC, and a rated impulse withstand of 8 kV. It is a 4P DC breaker with Ics and Icu ratings of up to 36 kA in the specified configurations, and a power loss of 5.8 W per pole.
Yes. The 1SDA123515R1 is designed for DC networks like battery storage and motor drive interfaces, offering robust short-circuit protection (Ics/Icu up to 36 kA in series), compact 4P construction, and front-terminal mounting for easy integration within DC distribution panels.
The device complies with IEC 60947-2 and GB/T 14028.2, and carries CE declarations and RoHS compliance. Additional eco-credentials include environmental and end-of-life considerations such as EPD and recyclability data to support sustainability reporting.
With a mechanical durability rating of 25,000 cycles and a compact, efficient design, the MCCB reduces maintenance frequency and energy waste. Front-terminal wiring speeds servicing, while documented end-of-life guidance and recyclable design support long-term lifecycle cost reduction.