ABB 1SDA123567R1 Moulded Case Circuit Breaker - IEC 60947-2
Part Number: 1SDA123567R1
Quick Summary
ABB 1SDA123567R1 is a DC moulded case circuit breaker that protects DC power distribution in industrial automation and energy storage. In DC systems, short-circuit events, arc flash risk, and downtime drive maintenance costs, so reliable protection is essential. Certified to IEC 60947-2 with CE conformity and RoHS/REACH compliance, plus ABB EcoSolutions for sustainable end-of-life workflows. Designed for easy installation in fixed-terminal, 3-pole configurations, it supports fast commissioning and reduces wiring complexity. With robust environmental data and recyclability metrics, this device helps you meet ESG targets while maintaining high-availability control systems.
Product Information
Extended Description
1SDA123567R1 ABB: XT2X160 DC TMA40 FF 3P
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.7 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Customs Tariff Number
85362000
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
DC
Mechanical Durability
25000 cycle | ;240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 3.71 W
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(250 V DC) 2 Poles in Series 100 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(250 V DC) 2 Poles in Series 100 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Short-Circuit Performance Level
X
Standards
IEC 60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation instructions XT2 DC IEC
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 40 A rated current in a 3P DC configuration. Business Impact: Delivers reliable protection for DC power buses with minimal voltage drop, reducing nuisance tripping and facilitating predictable load management. Application: DC distribution panels in automation and energy storage installations. Feature: Short-circuit performance with Ics up to 100 kA at 250 V DC and Icu up to 50 kA at 500 V DC. Business Impact: Fast, decisive interruption of faults to minimize bus voltage collapse and component damage. Application: High fault-current environments such as motor drives and energy storage inverters. Feature: Rated Operational Voltage of 500 V DC and Ui of 1000 V. Business Impact: Provides a robust safety margin for DC networks while simplifying design margins and compliance checks. Application: Industrial DC power networks and renewable energy interfaces. Feature: Release type TMA TM with fixed terminal connections. Business Impact: Reliable tripping with straightforward wiring reduces commissioning time and field maintenance costs. Application: Fixed installations in compact spaces where quick replacement is needed. Feature: Power loss of 3.71 W per pole and a compact footprint (90 mm width, 130 mm height, 82.5 mm depth). Business Impact: Lower heat generation and space-saving installation improve overall panel density and energy efficiency. Application: Dense control cabinets and automated lines. Feature: Mechanical durability rated at 25,000 cycles and 3P configuration. Business Impact: Long service life lowers maintenance frequency and total cost of ownership. Application: Critical DC protection in continuous operation facilities. Feature: Environmental and recyclability data (EPD, EN45555 closing resource loops 55.7%, RoHS/REACH). Business Impact: Supports sustainability reporting and compliance programs while enabling end-of-life disassembly. Application: ESG-focused projects and regulated markets.
Get a Quick Quote for a ABB 1SDA123567R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA123567R1?
Enquire Now