ABB 1SDA127160R1 Moulded Case Circuit Breaker -IEC60947-2
Part Number: 1SDA127160R1
Quick Summary
Moulded Case Circuit Breaker ABB 1SDA127160R1 is designed for robust DC protection in 3-pole automation panels. It safeguards critical DC buses, preventing equipment damage and costly downtime in demanding environments. This device aligns with IEC 60947-2 and GB/T 14028.2, carries CE certification, and satisfies RoHS requirements, supporting regulatory compliance and sustainability targets. ABB EcoSolutions adds value by enabling end-of-life planning and recyclability while reducing waste. With a 100 A rated current, 750 V DC operating voltage, and 8 kV impulse withstand, it delivers predictable tripping behavior under fault conditions. For system integrators and procurement teams, this translates to lower total cost of ownership, easier maintenance, and improved panel density when space is at a premium.
Product Information
Extended Description
1SDA127160R1 ABB: XT4S DC 160 TMD100 FF 3P
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT4 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT4 TM (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 56.3 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Customs Tariff Number
85362000
Product Net Width
105 mm
Product Net Height
160 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.5 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
DC
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 6.20 W
Rated Current (In)
100 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(250 V DC) 2 Poles in Series 50 kA | (500 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA | (750 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(250 V DC) 2 Poles in Series 50 kA | (500 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA | (750 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
250 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
S
Standards
IEC 60947-2 | GB/T 14028.2
Sub-type
XT4
Terminal Connection Type
Fixed Circuit-Breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT4
Instructions and Manuals
Installation instructions XT4 DC IEC
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Current rating and configuration establish the core protection level for DC distribution. With 100 A nominal current and a fixed 3P contact arrangement, the device fits standard 3-phase DC rails in automation cabinets, reducing the need for oversized components. This translates to smaller panel footprints and more efficient wiring, which is especially valuable in space-constrained control rooms and machine enclosures. Release and trip characteristics ensure fast, predictable disconnection under fault. The Tmax TM/TMD release in XT4 family delivers selective protection with clear coordination, helping prevent unnecessary trips in healthy subcircuits. In practice, engineers rely on consistent arc-quenching performance to improve safety margins and uptime during high-energy DC faults. Electrical strength and protection ratings are designed for demanding DC bus architectures. Rated Operational Voltage is 750 V DC, with Rated Insulation Voltage of 1000 V and 8 kV rated impulse withstand, giving designers headroom to protect critical loads. Service and Ultimate Short-Circuit Capacities are up to 50 kA depending on voltage and pole configuration, ensuring robust fault clearance across multiple circuit branches. Mechanical durability is substantial, with 25,000 cycles at 240 cycles per hour. The unit weighs 2.5 kg and uses Fixed Circuit-Breaker terminals, enabling a solid, vibration-resistant connection and straightforward installation. The compact dimensions (105 mm wide, 160 mm high, 82.5 mm deep) support dense panel layouts while maintaining reliable contact integrity. Sustainability and compliance features are built in. ABB EcoSolutions support disassembly instructions for end-of-life handling, plus an Environmental Product Declaration (EPD) for Tmax XT4 TM. Recyclability is designed per EN45555 at 56.3%, and the RoHS declarations confirm compliance with EU directives; Customs tariff number is 85362000. Practical installation considerations help installers and buyers choose confidence. The fixed-terminal design reduces wiring errors and simplifies field wiring in new builds or retrofits, while the 100 A / 750 V DC rating aligns with common DC power rails found in automation plants. For system integrators, the XT4 family provides consistent trip curves, predictable maintenance intervals, and long-term reliability.
Get a Quick Quote for a ABB 1SDA127160R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA127160R1?
Enquire Now