ABB AF116B-30-22-11 Contactor - IEC/UL 60947-4-1 Certified

Part Number: 1SFL427063R1122
Manufacturer
ABB
Part number
1SFL427063R1122

Quick Summary

AF116B-30-22-11 Contactor by ABB is a 3-pole motor starter designed to control motors up to 55 kW at 400 V AC (AC-3). In practice, panel builders face voltage swings and energy waste in unstable networks; this model addresses that with AF technology and a wide control voltage range. It carries IEC/EN 60947-4-1, UL 60947-4-1, and CE certifications for global compliance, enabling safer, scalable installations. The compact block design, pre-mounted auxiliary contacts, and extendable accessory options deliver tangible business value by reducing panel size, wiring complexity, and total cost of ownership while maintaining reliability in industrial environments.

Product Information

Extended Description

1SFL427063R1122 ABB: The AF116B-30-22-11 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 60 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 116 A | (440 V) 55 °C 116 A | (500 V) 55 °C 110 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 116 A | (220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 116 A | (440 V) 60 °C 116 A | (500 V) 60 °C 110 A | (690 V) 60 °C 65 A | (380 / 400 V) 60 °C 116 A | (220 / 230 / 240 V) 60 °C 116 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (175 V) 2 Poles in Series, 40 °C 160 A | (175 V) 2 Poles in Series, 60 °C 145 A | (175 V) 2 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (260 V) 3 Poles in Series, 40 °C 160 A | (260 V) 3 Poles in Series, 60 °C 145 A | (260 V) 3 Poles in Series, 70 °C 130 A | (72 V) 1-Pole, 40 °C 160 A | (72 V) 1-Pole, 60 °C 145 A | (72 V) 1-Pole, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A | (90 V) 1 Pole, 40 °C 160 A | (90 V) 1 Pole, 60 °C 145 A | (90 V) 1 Pole, 70 °C 130 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Power Loss
6 W | at Rated Operating Conditions per Pole 6 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 160 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 104 A | (440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511503
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210545
Feature: Three-pole block contactor rated for up to 690 V main circuit and 160 A AC-1 current. Business Impact: Handles robust motor starting with lower risk of overheating, enabling reliable operation of conveyors, pumps, and fans. Application: Industrial drives and automation panels requiring dependable AC-1 switching at high voltage. Feature: AF technology with a wide control voltage range (24–60 V AC, 50/60 Hz; 20–60 V DC). Business Impact: Reduces energy waste from control voltage variations and minimizes panel energy consumption. Application: Panels in electrically noisy or remote installations with fluctuating control signals. Feature: Built-in surge protection and compact block design. Business Impact: Improves network resilience and saves space in crowded enclosures. Application: OEM panels where space and protection against transients are critical. Feature: Auxiliary contacts and extensibility with add-on blocks. Business Impact: Streamlines control logic upgrades and simplifies expansion without major rewiring. Application: Control circuits needing additional NO/NC contacts for interlocking and status signaling. Feature: Coil consumption and efficiency specs (Holding 5.5 VA; Pull-in 225 VA at AC; DC pull-in 210 W; 6 W per pole power loss). Business Impact: Lowers standby current and energy costs across a year-long duty cycle. Application: Systems with continuous coil energization and frequent switching. Feature: Mechanical durability and switching capacity (5 million cycles; 300 cycles/hour). Business Impact: Long service life with predictable maintenance intervals, reducing downtime. Application: High-usage automation lines demanding high durability; predictable maintenance planning. Feature: Mounting and dimensions (Main Circuit: Bars; Product Net Width 90 mm; Height 150 mm; Depth 126 mm; Weight 1.55 kg). Business Impact: Easier installation and precise fit within standard enclosures. Application: Panel builders selecting compact, reliable contactors for dense control cabinets.

Get a Quick Quote for a ABB 1SFL427063R1122

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL427063R1122? Enquire Now

FAQs

The AF116B-30-22-11 supports a wide coil voltage range of 24–60 V AC at 50/60 Hz and 20–60 V DC, enabling compatibility with varied control circuits and networks while maintaining reliable pull-in performance and minimal sensitivity to voltage fluctuations.
Main circuit rated up to 690 V with AC-1 current of 160 A at 40 °C, and AC-3 ratings of 116 A across several voltages (including 415–690 V). It controls motors up to 55 kW at 400 V AC (AC-3) or 75 hp at UL ratings, making it suitable for typical industrial drives.
Yes. It includes built-in surge protection, a compact block design, and high mechanical durability (up to 5 million cycles) with a rated short-time withstand capability. These features help maintain reliability in environments with transients and frequent switching.
Absolutely. The AF116B-30-22-11 has pre-mounted auxiliary contacts and is designed to be extended with add-on auxiliary contact blocks, allowing flexible control logic without extensive rewiring.
The contactor carries IEC/EN 60947-1 and 60947-4-1 standards, UL 60947-4-1, CSA equivalents, and CE declarations. This combination supports global panel integration and regulatory compliance for commercial and industrial applications.