ABB AF116B-30-22-12 Contactor - 690 V IEC/UL Listed
Part Number: 1SFL427063R1222
Quick Summary
ABB AF116B-30-22-12 Contactor is a 3-pole motor starter used to drive 55 kW motors at 400 V in demanding applications. It tackles control-voltage fluctuations and surge-induced trips by offering a wide control voltage range and built-in protection, simplifying panel design and reliability. It carries IEC/EN 60947-4-1 and UL 60947-4-1 approvals, CSA recognition, and EN 50155 rail applicability where required. Designed for reliable motor protection and control in modern automation panels, it's compatible with add-on auxiliary blocks and ABB EcoSolutions to support sustainable, scalable installations. This compact 3-pole design reduces panel space while delivering robust performance for industrial automation projects today.
Product Information
Extended Description
1SFL427063R1222 ABB: The AF116B-30-22-12 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 60 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 116 A | (440 V) 55 °C 116 A | (500 V) 55 °C 110 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 116 A | (220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 116 A | (440 V) 60 °C 116 A | (500 V) 60 °C 110 A | (690 V) 60 °C 65 A | (380 / 400 V) 60 °C 116 A | (220 / 230 / 240 V) 60 °C 116 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (175 V) 2 Poles in Series, 40 °C 160 A | (175 V) 2 Poles in Series, 60 °C 145 A | (175 V) 2 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (260 V) 3 Poles in Series, 40 °C 160 A | (260 V) 3 Poles in Series, 60 °C 145 A | (260 V) 3 Poles in Series, 70 °C 130 A | (72 V) 1-Pole, 40 °C 160 A | (72 V) 1-Pole, 60 °C 145 A | (72 V) 1-Pole, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A | (90 V) 1 Pole, 40 °C 160 A | (90 V) 1 Pole, 60 °C 145 A | (90 V) 1 Pole, 70 °C 130 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
6 W | at Rated Operating Conditions per Pole 6 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 160 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 104 A | (440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511497
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210546
Wide control voltage tolerance from 48 to 130 V AC or DC enables flexible actuation across networks without swapping coils. This reduces inventory and wiring complexity, shortens commissioning time, and improves reliability in environments with fluctuating mains. Ideal for automation panels in conveyors, pumps, and fans where voltage fluctuations are common. Built-in surge protection and the compact AF block design lower the risk of nuisance trips and save panel space by combining protection and switching in one module, enabling cleaner wiring and faster assembly in space-constrained control cabinets. The design ships with pre-mounted auxiliary contacts (two NO and two NC) and is easily extended with add-on auxiliary contact blocks, supporting scalable control and straightforward upgrades for growing lines and OEM machines. This enables quick expansion of control signals without rewiring, simplifying commissioning and future-proofing motor control solutions across manufacturing plants. High mechanical durability and defined switching performance—up to 5 million cycles and 300 cycles per hour—reduce maintenance intervals and downtime in production lines. The coil and power characteristics deliver low energy demand with 6 W per pole power loss and compact dimensions (90 mm width, 126 mm depth, 150 mm height), contributing to lower energy use and smaller cabinet footprints in automotive, packaging, and process industries.
Get a Quick Quote for a ABB 1SFL427063R1222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL427063R1222?
Enquire Now
FAQs
Yes. The AF116B-30-22-12 is a 3-pole main contactor rated for three-phase systems up to 690 V and 400 V in common industrial drives. It ships with pre-mounted auxiliary contacts (two NO and two NC) and can be extended with add-on auxiliary contact blocks for scalable control signals, reducing wiring and rework during upgrades.
The coil supports 48–130 V for AC 50/60 Hz and DC operation. Coil power includes 4 VA holding at max rated voltage (50/60 Hz) and 180 VA pull-in (AC) or 150 W (DC). This offers flexible actuation with energy-efficient operation across variable supply conditions.
Yes. It adheres to IEC/EN 60947-4-1 and UL 60947-4-1 standards, with EN 50155 applicability for rail use where parts are applicable. This makes the AF116B-30-22-12 suitable for rail equipment and other demanding environments while maintaining safety and performance.
It carries IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, EN 50155 (applicable parts), TR CU 001/2011, and IEC 61373 among others. This broad certification base supports global deployment in industrial, rail, and OEM applications with confidence in safety and performance.
With 5 million mechanical cycles and 300 cycles per hour, the AF116B-30-22-12 offers long life and reduced maintenance downtime. Its low coil power (6 W per pole) and compact footprint decrease energy use and panel size, enabling faster installation, fewer spare parts, and lower total cost of ownership in automation and manufacturing facilities.