ABB 1SFL427063R1322 Block Contactor - IEC/EN 60947-4-1, UL 60947-4-1
Part Number: 1SFL427063R1322
Quick Summary
Block Contactor ABB 1SFL427063R1322 is a 3-pole motor starter designed for industrial automation. In panels with fluctuating control voltages, the wide range control input reduces nuisance trips and minimizes energy waste. This device carries IEC/EN 60947-1, IEC/EN 60947-4-1 and UL 60947-4-1 certifications, with CE and UKCA marks for global compliance. By leveraging AF technology and built-in surge protection, the unit delivers reliable operation in unstable networks while remaining compact and easily expandable with auxiliary contact blocks—supporting sustainable, long-term motor protection in modern machines and lines.
Product Information
Extended Description
1SFL427063R1322 ABB: The AF116B-30-22-13 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 60 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 116 A | (440 V) 55 °C 116 A | (500 V) 55 °C 110 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 116 A | (220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 116 A | (440 V) 60 °C 116 A | (500 V) 60 °C 110 A | (690 V) 60 °C 65 A | (380 / 400 V) 60 °C 116 A | (220 / 230 / 240 V) 60 °C 116 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (175 V) 2 Poles in Series, 40 °C 160 A | (175 V) 2 Poles in Series, 60 °C 145 A | (175 V) 2 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (260 V) 3 Poles in Series, 40 °C 160 A | (260 V) 3 Poles in Series, 60 °C 145 A | (260 V) 3 Poles in Series, 70 °C 130 A | (72 V) 1-Pole, 40 °C 160 A | (72 V) 1-Pole, 60 °C 145 A | (72 V) 1-Pole, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A | (90 V) 1 Pole, 40 °C 160 A | (90 V) 1 Pole, 60 °C 145 A | (90 V) 1 Pole, 70 °C 130 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss
6 W | at Rated Operating Conditions per Pole 6 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 160 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 104 A | (440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511480
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210547
Feature: Wide control voltage range (100-250 V AC/ DC) ensures compatibility with varied control signals, reducing the need for external power supplies and simplifying panel wiring. Effect: Lowers installation costs and enables quicker commissioning in mixed-voltage environments. Application: Suitable for automation panels where control signals vary across shifts or equipment fleets. Feature: Built-in surge protection protects coil circuits and auxiliary contacts from voltage spikes, improving reliability. Effect: Fewer unplanned outages and reduced maintenance. Application: Key in motors powering conveyors and pumps in environments with electrical noise. Feature: 3-pole main circuit rated up to 690 V with IeAC-1 up to 160 A and AC-3/AC-3e ratings up to 116 A at 415–690 V. Effect: Higher starting torque handling and robust motor control for mainstream industrial motors. Application: Suitable for fans, pumps, and other load classes in automation lines. Feature: Block-design with pre-mounted auxiliary contacts and compatibility with add-on contact blocks. Effect: Modular expansion, simplified wiring, and reduced spare parts inventory. Application: Quick tailoring for custom control circuits in OEM equipment. Feature: Energy efficiency and durability—6 W per pole, 5 million mechanical cycles, and ABB EcoSolutions alignment. Effect: Lower operating costs, longer service life, and support for sustainability goals. Application: Harsh factory environments requiring reliable lifecycle economics.
Get a Quick Quote for a ABB 1SFL427063R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL427063R1322?
Enquire Now
FAQs
Install the unit as a 3-pole main circuit device with Bars for the main contacts and use the pre-mounted auxiliary contacts to extend control circuitry. Mounting is designed for a compact block footprint; ensure proper clearance and secure wiring using the standard ferrules. Wire the coil to a 100-250 V control circuit (AC or DC) and verify coil polarity where applicable. Consider adding auxiliary contact blocks for expanded signaling in your control loop.
AC-1 rating is up to 160 A at 690 V, providing reliable general-use switching for resistive and slightly inductive loads. AC-3 ratings vary by voltage: up to 116 A at 415–690 V for motor switching, with AC-3e similar values for 60°C operation. These ratings enable motor protection in standard industrial drives and equipment while supporting safe disconnection and reliable operation.
Yes. It is designed for motor protection and control in conveyors and pumps, with a 3P main circuit up to 690 V and 160 A AC-1 rating. The device also includes built-in surge protection, a wide coil voltage range, and compatibility with auxiliary contact blocks, making it adaptable to varying control signals and environmental conditions typical of material handling and pumping applications.
The contactor meets IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL 60947-4-1 and CSA C22.2 approvals. It also carries CE and UKCA marks, EN 50155 applicable parts, and RoHS/WEEE declarations. This array of certifications supports global deployment across industrial automation projects with rigorous regulatory requirements.
AF technology offers a wide control voltage range and robust performance across control signals, reducing energy waste and enabling stable operation in networks with voltage variations. The unit features 5 million mechanical cycles and 6 W per pole power loss, contributing to longer service life and lower lifecycle costs. Built-in surge protection further lowers maintenance and replacement needs, improving overall return on investment.