ABB AF116B-30-22-14 Contactor - IEC/EN 60947-4-1 Certified
Part Number: 1SFL427063R1422
Quick Summary
ABB AF116B-30-22-14 Contactor enables reliable motor control for industrial drives in manufacturing and process applications. In practice, control voltage fluctuations and unstable networks can cause nuisance tripping and energy waste; this device's broad AF technology operating range helps maintain stable operation. It meets IEC/EN 60947-4-1 and UL 60947-4-1 standards, with CE and UKCA conformity for global use. The compact block design accepts add-on auxiliary contact blocks and a wide range of accessories, reducing panel depth and wiring complexity. By combining built-in surge protection with proven mechanical durability, it delivers predictable performance under challenging conditions, while minimizing downtime and maintenance costs for engineering teams and procurement.
Product Information
Extended Description
1SFL427063R1422 ABB: The AF116B-30-22-14 is a 3 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 55 kW / 400 V AC (AC-3) or 75 hp / 480 V UL and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz ), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 60 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 116 A | (440 V) 55 °C 116 A | (500 V) 55 °C 110 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 116 A | (220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 116 A | (440 V) 60 °C 116 A | (500 V) 60 °C 110 A | (690 V) 60 °C 65 A | (380 / 400 V) 60 °C 116 A | (220 / 230 / 240 V) 60 °C 116 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (175 V) 2 Poles in Series, 40 °C 160 A | (175 V) 2 Poles in Series, 60 °C 145 A | (175 V) 2 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (260 V) 3 Poles in Series, 40 °C 160 A | (260 V) 3 Poles in Series, 60 °C 145 A | (260 V) 3 Poles in Series, 70 °C 130 A | (72 V) 1-Pole, 40 °C 160 A | (72 V) 1-Pole, 60 °C 145 A | (72 V) 1-Pole, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A | (90 V) 1 Pole, 40 °C 160 A | (90 V) 1 Pole, 60 °C 145 A | (90 V) 1 Pole, 70 °C 130 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Average Pull-in Value 50 Hz 260 V·A | Average Pull-in Value 60 Hz 260 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
6 W | at Rated Operating Conditions per Pole 6 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 160 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 104 A | (440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511473
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210000
Feature AF technology with a wide control voltage range of 250-500 V AC (50/60 Hz) plus DC option → Business Impact Enables robust operation across fluctuating networks, reducing nuisance trips and energy waste; Application suited for critical motor control in factories and processing lines. Feature 3-pole main circuit rated up to 690 V → Business Impact Supports motors up to 55 kW (AC-3) with reliable switching; Application conveyors, fans, pumps in heavy-duty environments. Feature built-in surge protection → Business Impact Eliminates extra suppressors and simplifies panel design; Application simplifies installation in machines exposed to mains transients. Feature pre-mounted auxiliary contacts (2 NO / 2 NC) and extensible auxiliary blocks → Business Impact Flexible control logic and future expansion; Application scalable machine control with minimal wiring. Feature 5 million mechanical cycles and 300 cycles/hour max switching → Business Impact Long service life and predictable maintenance cycles; Application suitable for high-cycle manufacturing lines. Feature coil consumption and control circuit details (260 VA pull-in, 16.1 VA hold) → Business Impact Reduces energy draw from control circuits; Application lowers overall panel power and cooling requirements. Certifications and standards compliance (IEC/EN 60947-1, IEC/EN 60947-4-1, UL/CSA) → Business Impact Global compatibility and regulatory assurance; Application across international plant networks.
Get a Quick Quote for a ABB 1SFL427063R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL427063R1422?
Enquire Now
FAQs
The device is a 3-pole block contactor with main contacts rated for up to 690 V and 160 A AC-1. It ships with pre-mounted auxiliary contacts (2 NO and 2 NC) and standard ferrules. Use the 90 mm wide, 126 mm deep, 150 mm high footprint and connect mains to the bars terminals; add-on auxiliary blocks can be attached to expand control logic as needed.
AC-1 rating at 690 V is 160 A (40 °C); at 60 °C it is 145 A; at 70 °C it is 130 A. AC-3 ratings cover multiple voltages: at 415 V, 55 °C 116 A; at 440 V 116 A; at 500 V 110 A; at 690 V 65 A; 380/400 V 116 A; and 220/230/240 V 116 A. These values define starting and running capabilities in typical motor drive applications.
Yes, the AF116B-30-22-14 family provides DC-1, DC-3, and DC-5 ratings. For example, DC-1 and DC-3 values reflect combinations such as 110 V with multiple poles in series, across 40–70 °C, up to 160 A. DC-5 follows similar patterns with up to 145 A under the specified DC conditions. These ratings support DC motor control or DC relay applications in mixed-voltage systems.
This ABB contactor is designed to meet IEC/EN 60947-1 and IEC/EN 60947-4-1, with UL 60947-4-1 and CSA compatibility. It also carries CE and UKCA declarations, plus UL certificates and EAC/CCC-related documentation. Compliance coverage supports global deployments in regulated industrial environments.
The AF116B-30-22-14 delivers energy efficiency through AF technology and a wide coil voltage range, reducing panel energy use and wiring. Its mechanical durability of 5 million cycles and built-in surge protection lower maintenance and replacement costs, while 3P design and modular auxiliary blocks simplify upgrades and spare-part planning for long-term plant ROI.