ABB 1SFL427262R1222 Block Contactor - UL/CSA 600V 160A

Part Number: 1SFL427262R1222
Manufacturer
ABB
Part number
1SFL427262R1222

Quick Summary

Block Contactor ABB 1SFL427262R1222 controls motors in industrial panels with reliable power switching. In many installations, spurious starts and control-voltage variations create downtime and energy waste; this device helps mitigate that with a wide coil-voltage range and integrated protections. The AF-based design delivers robust performance under demanding conditions while supporting easy expansion with add-on auxiliary blocks. Certifications such as CE, UKCA, UL/CSA and RoHS/REACH ensure compliance across global markets. By combining a compact footprint, energy-efficient coil usage, and scalable accessory options, it delivers tangible business value from reduced panel heat, lower maintenance, and improved system availability.

Product Information

Extended Description

1SFL427262R1222 ABB: The AF116B-40-22RT-12 is a 4 pole - 690 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 55 kW / 400 V AC (AC-3) / and switching power circuits up to 160 A (AC-1) or 160 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
120 mm
Product Net Depth / Length
128 mm
Product Net Height
150 mm
Product Net Weight
1.95 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 690 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 60 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 116 A | (440 V) 55 °C 116 A | (380 / 400 V) 55 °C 116 A | (220 / 230 / 240 V) 55 °C 116 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (175 V) 2 Poles in Series, 40 °C 160 A | (175 V) 2 Poles in Series, 60 °C 145 A | (175 V) 2 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (260 V) 3 Poles in Series, 40 °C 160 A | (260 V) 3 Poles in Series, 60 °C 145 A | (260 V) 3 Poles in Series, 70 °C 130 A | (350 V) 4 Poles in Series, 40 °C 200 A | (350 V) 4 Poles in Series, 60 °C 145 A | (350 V) 4 Poles in Series, 70 °C 130 A | (72 V) 1-Pole, 40 °C 160 A | (72 V) 1-Pole, 60 °C 145 A | (72 V) 1-Pole, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A | (90 V) 1 Pole, 40 °C 160 A | (90 V) 1 Pole, 60 °C 145 A | (90 V) 1 Pole, 70 °C 130 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 60 °C 145 A | (110 V) 2 Poles in Series, 70 °C 130 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 60 °C 145 A | (110 V) 3 Poles in Series, 70 °C 130 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 60 °C 145 A | (220 V) 3 Poles in Series, 70 °C 130 A | (72 V) 2 Poles in Series, 40 °C 145 A | (72 V) 2 Poles in Series, 60 °C 145 A | (72 V) 2 Poles in Series, 70 °C 130 A | (72 V) 3 Poles in Series, 40 °C 145 A | (72 V) 3 Poles in Series, 60 °C 145 A | (72 V) 3 Poles in Series, 70 °C 130 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 75 kW | (500 V) 75 kW | (690 V) 55 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss
12 W | at Rated Operating Conditions per Pole 12 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(600 V AC) 160 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp | (200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 20 Hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 40 Hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 50 Hp | (550 ... 600 V AC) Three Phase 100 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
CB Certificate
SEMKO_SE-77317
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF116B..RT - AF140B-40...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF116B..RT - AF140B-40...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
197 mm
Package Level 1 Height
155 mm
Package Level 1 Gross Weight
2.15 kg
Package Level 1 EAN
7320500509944
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Four-pole main contacts (4P) rated up to 690 V and 160 A (AC-1) ensure reliable motor switching and power distribution in high-demand applications; this translates to higher uptime and safer equipment shutdowns in packaging lines or material handling. Feature → Application: Wide control circuit voltage range 48–130 V AC/60 Hz and DC operation reduce wiring complexity and panel stock, enabling simpler installation across plants with varying control voltages. Feature → Business Impact → Application: Built-in surge protection and AF technology minimize nuisance tripping in unstable networks, enhancing process control in pump stations or conveyor systems. Feature → Application: Pre-mounted auxiliary contacts (2 NO/2 NC) and a block-type design enable straightforward addition of signaling or interlocking in control schemes. Feature → Business Impact → Application: Low coil consumption (4 V·A holding; 180 V·A pull-in; 150 W DC) lowers energy use and reduces heat in control cabinets, benefiting long-term operating costs across HVAC, machine tools, and automation panels. Feature → Application: 12 W power loss per pole under rated conditions and 5 million mechanical durability support long life cycles in harsh manufacturing environments, improving TCO for OEMs and end-users. Feature → Business Impact → Application: Compact dimensions (120 mm width, 128 mm depth, 150 mm height) and 1.95 kg weight simplify panel layout and enable denser installations in automation rooms. Feature → Application: Compatibility with CAD drawings (2D/3D) and availability of data sheets and manuals accelerate engineering onboarding and change management for machine builders. Certifications including CE, UKCA, UL/CSA, UR, URus, CCC, EAC, RoHS, and REACH ensure regulatory readiness across regions, reducing certification delays during installation or retrofit projects.

Get a Quick Quote for a ABB 1SFL427262R1222

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL427262R1222? Enquire Now

FAQs

The coil supports 48 to 130 V for both AC and DC operation, with 50/60 Hz options. This wide range allows panel designers to standardize control circuits across different voltage environments, reducing wiring variants and stocking requirements while maintaining reliable actuation under varying supply conditions.
Yes. The contactor is rated for AC-3 up to 55 kW at 380–400 V and UL/CSA ratings up to 160 A. It supports motor starter applications with solid performance in challenging loads, providing a dependable switch for high-power conveyors, pumps, and fans.
It features 4 main NO contacts and 4 poles (4P) with 2 auxiliary NO and 2 auxiliary NC contacts. Main circuit voltage is rated up to 690 V, with AC-1 current up to 160 A and AC-3 up to 116 A at common voltages. This configuration suits general power switching and motor control duties.
The device carries CE and UKCA declarations, UL/CSA general-use ratings, cURus, CCC, EAC certifications, and RoHS/REACH compliance. These attest to regulatory readiness across Europe, North America, and other markets, reducing certification lead times for multinational installations.
Its block-type design supports easy extension with add-on auxiliary contact blocks. Pre-mounted auxiliary contacts simplify wiring, and the product offers CAD dimensional drawings and comprehensive manuals. With dimensions of 120 mm W × 128 mm D × 150 mm H and a weight around 1.95 kg, it fits compact panels and enables straightforward integration.