ABB AX95-30-11-84 Contactor - CE UL 690V AC-3 96A
Part Number: 1SFL431074R8411
Quick Summary
ABB AX95-30-11-84 Contactor is a robust 3-pole motor starter for industrial automation panels. It delivers reliable switching in demanding loads while minimizing footprint. Engineers often face space, wiring complexity, and thermal overload risks in motor control; this device reduces those challenges with integrated auxiliary contacts and a compact form factor. It carries CE and UL certifications, along with RoHS and REACH compliance, supplemented by CCC declarations for global supply. With a compact 102 mm width, a 123.5 mm depth, and 148 mm height, plus a 1.9 kg weight, it fits standard enclosures and simplifies installation. The solution supports standard ABB control schemes and provides long lifecycles for high-demand applications, delivering predictable performance in manufacturing lines.
Product Information
Extended Description
1SFL431074R8411 ABB: AX95-30-11-84 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 90~150A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A | (690 V) 55 °C 135 A | (690 V) 60 °C 135 A | (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 96 A | (440 V) 55 °C 93 A | (500 V) 55 °C 80 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 96 A | (220 / 230 / 240 V) 55 °C 96 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 110 V | 60 Hz 110 ... 120 V
Power Loss
at Rated Operating Conditions per Pole 2.7 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Cable Clamp
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A95...A110, AX95...AX150
Package Level 1 Units
box 1 piece
Package Level 1 Width
140 mm
Package Level 1 Depth / Length
170 mm
Package Level 1 Height
130 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500500033
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application. The AX95-30-11-84 features three main normally open contacts plus one normally open and one normally closed auxiliary contact, enabling coordinated switching of motor circuits and control signals in a single device. This reduces wiring complexity and panel space while improving control reliability for conveyors, pumps, and fans in automated lines. Feature → Business Impact → Application. Rated insulation voltage of 690 V and a main circuit rating up to 1000 V support high-energy motor drives, enabling safer operation in mixed-voltage environments and meeting international standards for industrial installations. This enhances panel standardization and reduces stock variety for OEMs. Feature → Business Impact → Application. Coil voltage options include 50 Hz 110 V and 60 Hz 110–120 V, delivering regional compatibility and easier procurement for global factories. This simplifies cross-site deployments and minimizes downtime during coil replacements. Feature → Business Impact → Application. Power loss of 2.7 W per pole and a mechanical durability of 10 million cycles reduce operating heat and maintenance costs while extending life in continuous-duty applications like pumps and material handling systems. This supports energy-efficient designs and lowers total cost of ownership. Feature → Business Impact → Application. IP40 protection on auxiliary terminals and a robust cable clamp terminal design improve enclosure integrity and termination reliability, making field wiring faster and safer in harsh industrial environments. This accelerates installation, minimizes field faults, and enhances overall system uptime. Feature → Business Impact → Application. With compact dimensions (102 mm width, 123.5 mm depth, 148 mm height) and a 1.9 kg weight, the AX95-30-11-84 fits into tight control panels and standard mounting footprints, reducing cabinet real estate and enabling straightforward retrofits in legacy systems.
Get a Quick Quote for a ABB 1SFL431074R8411
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL431074R8411?
Enquire Now
FAQs
Yes. The AX95-30-11-84 is a 3P block contactor with three main normally open contacts plus one normally open and one normally closed auxiliary contact, designed for standard panel mounting. Its compact 102 mm width and 123.5 mm depth fit typical control enclosures, and the cable clamp terminals simplify field wiring. When pairing with ABB overload relays, it supports integrated motor protection for common industrial drives.
For AC-3 duty, the AX95-30-11-84 reaches up to 96 A at 415 V and 55 °C, and 93 A at 440 V. At 690 V, the rating is 65 A under the same temperature conditions. This makes it suitable for medium-power motors in automation lines, fans, and pumps while maintaining reliable switching performance.
This ABB contactor carries CE and UL certifications, along with RoHS and REACH compliance. It also includes CCC declarations and CMRT documentation for supply-chain transparency. WEEE classification is B2B, aligning with industrial disposal requirements. These certifications support global deployment and regulatory compliance in diverse markets.
The AX95-30-11-84 delivers 10 million mechanical cycles and 2.7 W power loss per pole, supporting long service life and energy-efficient operation in continuous-duty applications. Its IP40 auxiliary terminals and cable clamp design further improve termination reliability, reducing maintenance needs and field faults in harsh environments like factories and process lines.
Coil voltage options include 110 V for 50 Hz and 60 Hz systems (110–120 V range). This enables cross-regional compatibility and simplifies stocking for multinational plants. The unit is designed for integration with standard ABB control schemes and can be paired with ABB thermal overload relays for complete start/stop control in 3P motor circuits.