ABB 1SFL431074R9002 Block Contactor is used to control 3‑phase motors in power circuits up to 690 V AC. Engineers often struggle with fitting robust motor starters into compact switchgear and cleanly wiring control circuits. The device carries CE Declaration of Conformity, UL/cULus certification, and CCC approval, supporting global compliance across manufacturing sites. Its block design features three main normally open contacts and a single normally open/closed auxiliary contact, with optional add-on blocks for side mounting and wide accessory compatibility. With a rated AC-3 current up to 96 A at common voltages and low power loss per pole, it helps reduce heat, energy waste, and maintenance costs while integrating with modern automation systems.
Product Information
Extended Description
1SFL431074R9002 ABB: AX95...AX115 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 90~150A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A | (690 V) 60 °C 135 A | (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 96 A | (440 V) 55 °C 93 A | (500 V) 55 °C 80 A | (690 V) 55 °C 65 A | (380 / 400 V) 55 °C 96 A | (220 / 230 / 240 V) 55 °C 96 A
Rated Operational Power AC-3 (Pe)
(380 / 400 V) 45 kW
Power Loss
at Rated Operating Conditions per Pole 2.7 W
Product Name
Block Contactor
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A95...A110, AX95...AX150
Package Level 1 Units
box 1 piece
Package Level 1 Width
140 mm
Package Level 1 Depth / Length
170 mm
Package Level 1 Height
130 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500511602
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3P block contactor with 3 mainNO contacts and 1 NO/1 NC auxiliary contact. Business Impact: Simplifies motor control wiring, reduces panel depth, and enables straightforward expansion with add-on blocks. Application: Ideal for compact motor starters in conveyors, pumps, and fans where space is at a premium and reliability matters. Long-tail keywords addressed include 3-pole motor starter, block contactor, and auxiliary contact blocks. Feature: AC-operated control circuit with high current ratings. Business Impact: Delivers robust performance for demanding drives while keeping control circuits simple and fault-tolerant. Application: Suitable for AC-3 driven loads up to 96 A at 415–690 V, minimizing overdesign and energy waste. Feature: Add-on auxiliary contact blocks for side mounting. Business Impact: Improves wiring flexibility and enables customization without changing the base device. Application: Quick integration into existing control panels and interlock schemes for enhanced safety and control. Feature: Compact dimensions and weight. Business Impact: Allows denser panel layouts and easier installation in space-constrained MCCs or switchgear. Application: Fits standard 102 mm width with 123.5 mm depth and 148 mm height, weighing 1.9 kg for easier handling during installation. Feature: Global compliance certifications. Business Impact: Reduces procurement risk and speeds cross-border projects with CE, UL/cULus, CCC, REACH, RoHS, and WEEE alignment. Application: Suitable for multinational facilities and regulated industries requiring traceable conformity. Feature: Operating altitude and environmental readiness. Business Impact: Maintains performance without derating up to 3000 m, expanding application in high-altitude facilities. Application: Mining, processing plants, and remote installations where altitude challenges exist.
Get a Quick Quote for a ABB 1SFL431074R9002
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL431074R9002?
Enquire Now
FAQs
The ABB 1SFL431074R9002 is a 3P block contactor with 3 main NO contacts and 1 NO/1 NC auxiliary contact. It supports add-on auxiliary contact blocks for side mounting, enabling flexible wiring and expansion within standard control panels. This makes it easier to tailor the device to specific motor control and interlock requirements without replacing the base unit.
For AC-3 duty, the contactor delivers up to 96 A at 415 V (55 °C) and 96 A at 440–690 V ranges, with 80 A at 500 V and 65 A at 690 V (all at 55 °C where listed). These ratings support reliable motor starting for common 3‑phase drives, enabling efficient selection for 380/400 V and 415/440/690 V systems.
Yes. The AX95/AX115 family, including the 1SFL431074R9002, specifies maximum operating altitude permissible without derating up to 3000 meters, making it suitable for equipment rooms and facilities in mountainous or high-altitude environments.
This block contactor carries CE Declaration of Conformity, UL/cULus certification, and CCC approval, along with REACH and RoHS compliance. These certifications help satisfy regulatory and procurement requirements for global projects across manufacturing, energy, and process industries.
With a per-pole power loss of 2.7 W and a compact 1.9 kg profile, the device minimizes heat generation and energy waste, reducing cooling needs and wiring complexity. The availability of add‑on auxiliary blocks and CAD data accelerates installation and service, delivering faster time-to-value and lower total cost of ownership in motor control applications.