ABB 1SFL437001R7000 Block Contactor - 1000 V CE

Part Number: 1SFL437001R7000
Manufacturer
ABB
Part number
1SFL437001R7000

Quick Summary

ABB 1SFL437001R7000 Block Contactor is a high‑current switch for motor start in industrial drives. Engineers face limited coil voltage choices and temperature swings that threaten uptime. This family delivers CE and UL/CSA recognition with RoHS/WEEE compliance to ease global sourcing. Its 1000 V insulation, 3P frame and 48–130 V control options support reliable ABB AF-series coil compatibility. With three poles, it handles demanding motor loads while providing clear isolation and switching performance. Its data-rich specifications support reliable design, easier compliance checks and longer service life in harsh environments. Designed for global procurement, it aligns with IEC, UL/CSA and CE declarations, reducing engineering risk. This makes it a practical choice for medium- to heavy-duty motor control in manufacturing and process automation.

Product Information

Extended Description

1SFL437001R7000 ABB: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SBL407001R1300
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
Dimension Diagram
53540923-1
Product Net Width
90 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A | (690 V) 55 °C 135 A | (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 96 A | (440 V) 55 °C 93 A | (500 V) 55 °C 80 A | (690 V) 55 °C 65 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 96 A | (220 / 230 / 240 V) 55 °C 96
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 1 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 2 x 6 ... 65 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Cable Clamp
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 125 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 30 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-73661
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden | CQC Certificate, Contactor, AF95-30, AF95-30-11, AF110-30, AF110-30-11, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden | CCC Declaration of Conformity, Contactor, AF95-30, AF95-30-11, AF110-30, AF110-30-11, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500237397
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Finland)
3709254
E-Number (Norway)
3228269
E-Number (Sweden)
3228269
Feature → Business Impact → Application: Three-pole, three main contacts in a compact 3P frame delivers robust switching for three-phase motors, reducing panel depth and wiring complexity while enhancing reliability in drive systems. This translates to lower installation time and fewer field failures in conveyors, compressors, and pumps. Feature → Business Impact → Application: Wide control circuit voltage range 48–130 V AC/DC eliminates the need for multiple relays or interface adapters, cutting component count and stocking costs while simplifying control interfaces with PLCs and VFDs in machine automation. Feature → Business Impact → Application: Rated insulation voltage at 1000 V enables safe operation with higher voltage motors and distribution circuits, enabling simpler topologies for heavy-duty applications like press lines and material handling. Feature → Business Impact → Application: AC‑3 and AC‑1 current ratings across voltages (e.g., 96 A at 415 V AC-3, up to 145 A AC-1 at 690 V) provide flexibility for design margins, reducing over-dimensioning and improving energy efficiency in motor control and drive applications. Feature → Business Impact → Application: Coil consumption and power loss remain low (holding 7 V·A at 50/60 Hz, 2 W at DC) which reduces heat in control panels and extends component life, benefiting end users in high-ambient environments. Feature → Business Impact → Application: Mechanical durability of 10 million operations and a 300 cycles/hour maximum switching rate support long service life and predictable maintenance schedules for production lines, packaging equipment, and process automation. Feature → Business Impact → Application: IP20 coil terminals and IP10 main terminals plus robust connecting capacities (bar, flexible, and rigid conductors) enable quick, vibration-tolerant installations in cabinet interiors and distributed control panels. Feature → Business Impact → Application: Compliance and certifications (CE, UL/CSA, RoHS) simplify procurement across regions and reduce regulatory risk for OEMs supplying international facilities, including food, chemical, and power generation sectors. Feature → Business Impact → Application: Clear installation torque specs (Main Circuit 8 N·m) and terminal types (Cable Clamp) support repeatable tightening, reducing field issues and ensuring robust connections in harsh industrial environments.

Get a Quick Quote for a ABB 1SFL437001R7000

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL437001R7000? Enquire Now

FAQs

The contactor coil supports 50 Hz and 60 Hz operation within 48 to 130 V, and DC operation in the same 48–130 V range. This wide coil range allows direct interfacing with common PLCs and VFDs, reducing the need for auxiliary relays and simplifying panel wiring while maintaining reliable actuation across ambient temperatures.
AC-1 ratings at 690 V are 145 A at 40 °C, 135 A at 55 °C, and 115 A at 70 °C. AC-3 ratings include 96 A at 415 V, 93 A at 440 V, 80 A at 500 V, 65 A at 690 V, and 30 A at 1000 V, with 96 A at 380/400 V. These values help engineers size downstream protection and ensure proper motor starting and running performance.
Yes, it is rated for a main circuit insulation voltage of 1000 V, with an impulse withstand voltage (Uimp) of 8 kV. This makes it suitable for higher-voltage motor control and distribution tasks while maintaining safe isolation in the panel and compliance with IEC/UL standards.
The product carries CE declarations of conformity, UL/CSA compatibility, and RoHS compliance, with WEEE classification for B2B use. It is also supported by multiple third-party certificates (ABS, BV, GL, DNV GL, LR, RINA, etc.), facilitating global procurement and helping meet regulatory requirements in diverse industries.
Key installation notes include a main-circuit tightening torque of 8 N·m and cable-clamp terminal type for secure connections. Its 3P, 3N design reduces wiring complexity, while 10 million mechanical cycles and 300 cycles/hour switching capacity provide predictable maintenance intervals and long service life in demanding environments.