ABB 1SFL437062R7000 Block Contactor - CE/UL 1000V

Part Number: 1SFL437062R7000
Manufacturer
ABB
Part number
1SFL437062R7000

Quick Summary

Block Contactor ABB 1SFL437062R7000 provides reliable switching for three-phase motors in rail applications. Engineers often grapple with integrating variable control voltages and mounting constraints in tight spaces. This ABB model meets IEC 60947-1 and 60947-4-1, UL 60947-4-1, and CE conformity, with IP20 coil terminals and strong mechanical durability. Designed for straightforward integration, it supports a wide control voltage range and robust mounting, delivering predictable uptime and lower total cost of ownership. With 3-pole main contacts and 1 auxiliary NO/NC contact, it enables complex control logic in conveyors, pumps, or traction equipment. Its IEC/UL/CE certifications, 1000 V insulation, and compact footprint help you meet safety standards while reducing panel space requirements. Typical applications include rail signaling equipment, HVAC drives, and material handling systems where reliable isolation and timing are critical.

Product Information

Extended Description

1SFL437062R7000 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
1SFB535001G1005
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A | (690 V) 55 °C 135 A | (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 96 A | (440 V) 55 °C 93 A | (500 V) 55 °C 80 A | (690 V) 55 °C 65 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 96 A | (220 / 230 / 240 V) 55 °C 96
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 2 x 6 ... 65 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Ring-Tongue Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 125 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 30 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
13409/C0 BV
CB Certificate
SE-73661
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500260128
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Norway)
4115320
Feature → Business Impact → Application: The 100-250 V AC/DC control voltage range simplifies integration with existing automation stacks, reducing wiring complexity and BOM variety while ensuring reliable coil energization across standard control systems. This translates to faster commissioning and lower installation risk in rail, conveyor, and pumping applications. Feature → Business Impact → Application: Three main NO contacts plus one NO/NC auxiliary contact provide versatile control logic for motor starters with 3P configurations, enabling precise sequencing in material handling systems and traction drives, reducing mis-wiring and maintenance downtime. Feature → Business Impact → Application: Rated insulation voltage of 1000 V and 8 kV impulse withstand enhance protective margin in high-energy environments, supporting compliant operation in electrical rooms, substations, and on-board vehicle systems. Feature → Business Impact → Application: Mechanical durability of 10 million cycles and a maximum mechanical switching frequency of 300 cycles per hour deliver extended service life and predictable maintenance windows for heavy-usage installations such as conveyors and HVAC drives. Feature → Business Impact → Application: Clear mounting footprint and robust terminal design—102 mm width, 123.5 mm depth, IP20 coil terminals, IP10 main terminals—facilitate fast installation, secure wiring with M8 fasteners, and straightforward field servicing in compact control panels. Feature → Business Impact → Application: Compliance and safety certifications, including IEC/UL/CE declarations and 30 mm² main circuit connections, reduce qualification time for audits and accelerate approvals in railway, process, and packaging environments.

Get a Quick Quote for a ABB 1SFL437062R7000

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL437062R7000? Enquire Now

FAQs

The device features three main NO contacts and a single auxiliary NO/NC contact in a 3P configuration, supporting AC-1 and AC-3 motor duty. It uses 30 mm2 main circuit connections and supports flexible cable ends up to 35 mm2, with M8 terminal screws and a tightening torque of 8 N·m. This makes it straightforward to install in standard motor control panels and rail drive systems.
Key specs include a rated insulation voltage of 1000 V, rated operational currents for AC-3 up to 96 A at 415 V and 93 A at 440 V, and 30 A at 1000 V for DC-3. The contactor also offers a maximum electrical switching frequency of 300 cycles per hour (AC-1/AC-3) and 10 million mechanical cycles of durability, ensuring long service life in demanding environments.
Yes. The ABB 1SFL437062R7000 is designed with railway needs in mind and carries applicable standards such as IEC 60947-1/4-1 and EN 50155 applicable parts, along with CE and UL/CSA conformity. Its robust insulation, 1000 V rating, and reliable coil performance support safe operation in rail signaling, traction drives, and on-board control systems.
This contactor carries CE conformity, UL/CSA general use ratings, and various certificates (ABS, BV, CB, CQC, CCC, EAC, GL, LR, RINA, RMRS) as listed in its certificates and declarations section. It also comes with a CE Declaration of Conformity and REACH/RoHS compliance, helping to streamline regulatory qualifications across global markets.
With a mechanical durability of 10 million cycles and a 300 cycles/hour switching capability, maintenance intervals can be extended in steady-state operations, reducing downtime. The solid 100-250 V coil, 1000 V insulation, and rugged terminals minimize field faults. Overall, you gain lower lifecycle costs through fewer replacements, easier installation, and reliable performance in rail, conveyors, and HVAC drive systems.