ABB 1SFL437063R6911 Block Contactor - IEC/EN 60947-4-1

Part Number: 1SFL437063R6911
Manufacturer
ABB
Part number
1SFL437063R6911

Quick Summary

ABB 1SFL437063R6911 Block Contactor is a 3-pole AC/DC control device for railway traction and signaling applications. Engineers often contend with narrow coil ranges and thermal stress in high-duty cycles, making reliable operation challenging in rail electronics. This model accommodates a wide control voltage of 48–130 V and is designed to meet IEC/EN 60947-4-1 and UL 60947-4-1 expectations, with additional CE/UKCA declarations and rail-grade protection. Its rugged construction supports continuous service in demanding environments, while compact integration with standard ABB accessories reduces panel footprint and wiring complexity. Leveraging this contactor translates to improved uptime, predictable maintenance, and safer, compliant control of demanding rail systems.

Product Information

Extended Description

1SFL437063R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
Dimension Diagram
53540923-1
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 145 A | (690 V) 55 °C 135 A | (690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 96 A | (440 V) 55 °C 93 A | (500 V) 55 °C 80 A | (690 V) 55 °C 65 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 96 A | (220 / 230 / 240 V) 55 °C 96
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 55 °C 135 A | (110 V) 2 Poles in Series, 70 °C 115 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 55 °C 135 A | (110 V) 3 Poles in Series, 70 °C 115 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 55 °C 135 A | (220 V) 3 Poles in Series, 70 °C 115 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 55 °C 135 A | (110 V) 2 Poles in Series, 70 °C 115 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 55 °C 135 A | (110 V) 3 Poles in Series, 70 °C 115 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 55 °C 135 A | (220 V) 3 Poles in Series, 70 °C 115 A | (72 V) 1-Pole, 40 °C 130 A | (72 V) 1-Pole, 55 °C 130 A | (72 V) 1-Pole, 70 °C 115 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 145 A | (110 V) 2 Poles in Series, 55 °C 135 A | (110 V) 2 Poles in Series, 70 °C 115 A | (110 V) 3 Poles in Series, 40 °C 145 A | (110 V) 3 Poles in Series, 55 °C 135 A | (110 V) 3 Poles in Series, 70 °C 115 A | (220 V) 3 Poles in Series, 40 °C 145 A | (220 V) 3 Poles in Series, 55 °C 135 A | (220 V) 3 Poles in Series, 70 °C 115 A
Rated Operational Power AC-3 (Pe)
(415 V) 55 kW | (440 V) 55 kW | (500 V) 55 kW | (690 V) 55 kW | (1000 V) 40 kW | (380 / 400 V) 45 kW | (220 / 230 / 240 V) 25 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 2 x 6 ... 65 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Cable Clamp
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 125 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 7-1/2 hp | (200 ... 208 V AC) Three Phase 30 hp | (200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 30 hp | (240 V AC) Single Phase 20 hp | (440 ... 480 V AC) Three Phase 60 hp | (550 ... 600 V AC) Three Phase 75 hp
Full Load Amps Motor Use
(120 V AC) Single Phase 80 A | (200 ... 208 V AC) Three Phase 92 A | (220 ... 240 V AC) Three Phase 80 A | (240 V AC) Single Phase 88 A | (440 ... 480 V AC) Three Phase 77 A | (550 ... 600 V AC) Three Phase 77 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-73661
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500256473
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → 3P 3NO main contacts with 1NO auxiliary and 1NC auxiliary → Business Impact → Simplifies motor/control circuits, reducing wiring complexity and panel space while enabling reliable control of multi-pedestal loads; Application → Railway control panels, traction systems, industrial conveyors. Feature → Coil control voltage 48–130 V AC/DC → Business Impact → Maximizes compatibility with diverse control sources and minimizes stock variety; Application → Centralized control cabinets, new installations, retrofit projects. Feature → Rated insulation voltage 1000 V and impulse withstand 8 kV → Business Impact → Ensures safety margins and regulatory compliance in high-energy environments; Application → High-voltage switching in rail and industrial automation. Feature → Mechanical durability of 10 million cycles → Business Impact → Extends service life and reduces maintenance downtime; Application → Frequent switching in signaling and automation panels. Feature → Compact dimensions (102 mm width, 123.5 mm depth, 148 mm height) and mass of 1.9 kg → Business Impact → Easier installation and enclosure-friendly integration, lowering overall project costs; Application → Space-constrained control rooms and vehicle-mounted panels. Feature → Protection ratings IP20 for coil and IP10 for main terminals → Business Impact → Improved dust protection and safe handling in assembly lines; Application → Indoor electrical panels and industrial installations. Feature → Compliance with IEC/EN 60947-4-1, UL 60947-4-1, and CE declarations → Business Impact → Streamlined procurement with validated standards, accelerating compliance-driven projects; Application → Global deployments in rail and industrial markets.

Get a Quick Quote for a ABB 1SFL437063R6911

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL437063R6911? Enquire Now

FAQs

The unit uses a 48–130 V coil (AC/DC) and features 3 main NO contacts plus 1 NO auxiliary and 1 NC auxiliary, with a 3P configuration. This enables flexible control schemes, straightforward wiring, and compatibility with standard ABB accessories for simplified panel design and faster commissioning.
Yes. It provides a rated insulation voltage of 1000 V and an impulse withstand of 8 kV, with conformance to IEC/EN 60947-4-1 and UL 60947-4-1, supported by CE declarations. These characteristics ensure safe operation in rail and industrial settings and aid in meeting regional electrical safety requirements.
Absolutely. The device is a 3-pole Block Contactor designed for railway applications, offering robust switching, mechanical durability, and compatibility with rail standards such as IEC 60947-4-1, EN 50155 applicable parts, and UL/CSA ratings, making it suitable for traction, signaling, and automation panels.
It delivers up to 10 million mechanical cycles and a maximum mechanical switching frequency of 300 cycles per hour, with coil consumption optimized for holding and pull-in at rated voltages. This translates to reduced maintenance downtime and lower lifecycle costs in high-cycle installations.
Consider the 102 mm width, 123.5 mm depth, and 148 mm height, with a weight of 1.9 kg and M8 terminal connectors. Connections support Bar 30 mm² main circuit wiring and 0.75–2.5 mm² auxiliary conductors, while a dimension diagram 53540923-1 and standard tightening torque of 8 N·m simplify mounting and ensure consistent electrical integrity.