ABB 1SFL447001R3300 Block Contactor - AF Technology, 3P 690 V IEC / 600 V UL
Part Number: 1SFL447001R3300
Quick Summary
Block Contactor 1SFL447001R3300 by ABB enables reliable motor control for heavy-duty applications such as conveyors, pumps and fans. In facilities with fluctuating control voltages, standard contractors can trip or chatter, causing downtime and wasted energy. This device integrates AF technology with a wide control voltage range and built-in surge protection, backed by CE, UL and UKCA certifications. For engineers and procurement teams, it combines compact footprint with easy integration into existing electrical protection and control schemes, delivering energy efficiency and dependable operation in industrial automation environments.
Product Information
Extended Description
1SFL447001R3300 ABB: The AF140-30-00-33 is a 3 pole - 690 V IEC or 600 V UL contactor with double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 200 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
142.5 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 200 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (500 V) 55 °C 130 A | (690 V) 55 °C 80 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 140 A | (440 V) 60 °C 140 A | (500 V) 60 °C 130 A | (690 V) 60 °C 80 A | (380 / 400 V) 60 °C 140 A | (220 / 230 / 240 V) 60 °C 140 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Short-Circuit Protective Devices
gG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss
at Rated Operating Conditions per Pole 9 W
Operate Time
Between Coil De-energization and NO Contact Opening 37 ... 47 ms | Between Coil Energization and NO Contact Closing 25 ... 55 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Double Clamp
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp | (200 V AC) Three Phase 40 hp | (208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 20 Hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 40 Hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 50 Hp | (550 ... 600 V AC) Three Phase 125 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-70479M1
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
DNV GL Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
EAC Certificate
9AKK107046A8618
GL Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500480915
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: AF technology enables a wide control voltage range (100–250 V AC/ DC), allowing the coil to pull in reliably even with voltage variations, reducing nuisance trips and panel energy use. This translates to lower energy waste and fewer control faults in automation systems, such as material handling lines and process skids. Application: Best for facilities with unstable power quality where consistent coil activation is critical. Feature → Business Impact → Application: The AF block design is compact and extendable with auxiliary contact blocks, simplifying panel layouts and future expansion while preserving DIN rail real estate. Application: New installations and retrofit projects in packaging lines and HVAC control panels benefit from quick upgrades and scalable control. Feature → Business Impact → Application: Built-in surge protection provides protection against surges on the control circuit, increasing overall reliability and reducing contact wear. Application: Critical in motors and drives in mining, water treatment, and manufacturing lines where continuity matters. Feature → Business Impact → Application: Three-pole, 690 V main circuit rating and high Ie values (AC-3) enable safe switching of motors up to 75 kW, lowering equipment downtime and enabling accurate control of fans, pumps, and conveyors. Application: Heavy-duty motor control panels requiring robust switching performance. Feature → Business Impact → Application: Coil consumption and power loss are optimized (holding and pull-in values specified), improving energy efficiency of control circuits and reducing total cost of ownership. Application: Energy-conscious machine control in continuous production lines. Feature → Business Impact → Application: Mechanical durability of 5 million cycles and IP40 protection for auxiliary terminals increase service life in harsh industrial environments. Application: Food, chemical, and metal processing plants where durability and reliability are essential.
Get a Quick Quote for a ABB 1SFL447001R3300
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL447001R3300?
Enquire Now
FAQs
Yes. The 1SFL447001R3300 is a 3-pole block contactor with a wide control voltage range of 100-250 V AC or DC, designed for IEC and UL environments. It uses double clamp terminals for secure wiring and supports AF technology, making it straightforward to install in standard control panels and motor starters.
For AC-3 operation, the contactor handles up to 140 A at 415 V, 440 V and 500 V, and reduces to 80 A at 690 V, with P_e around 75 kW at 415 V and 75 kW at 690 V in respective configurations. This makes it suitable for high-inertia motors in conveyors and pumps while meeting safety margins per IEC 60947-4-1.
Absolutely. With 3P configuration, 690 V main circuit, and AF technology, the device supports motors up to 75 kW, with robust surge protection and compact dimensions. Its IP40 auxiliary terminals and 3-pole design make it reliable in industrial automation environments such as conveyors, pumps, and process lines.
The 1SFL447001R3300 carries CE conformity, UL/CSA certification, and UKCA marking, along with RoHS and REACH declarations. These certifications help ensure regulatory compliance in global projects and simplify documentation for audits and customer qualifications.
AF technology provides a wide control voltage range, reducing coil misoperation and energy waste. The built-in surge protection minimizes contact wear, while the robust mechanical durability (up to 5 million cycles) lowers maintenance frequency and extends service life in demanding production lines.