ABB 1SFL447063R1122 Contactor - IEC/EN 60947-4-1
Part Number: 1SFL447063R1122
Quick Summary
ABB 1SFL447063R1122 Contactor is a three-pole motor starter for railway applications. Engineers rely on it to reliably start motors, isolate circuits, and distribute power in harsh rail environments. The device carries IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60947-4-1 certifications to ensure safety and regulatory compliance across international rail projects. With a wide control voltage range and a high main circuit rating, it supports flexible control topologies while reducing lifecycle costs. This combination delivers dependable performance, easy integration with existing control systems, and a lower total cost of ownership for rail operators and contractors.
Product Information
Extended Description
1SFL447063R1122 ABB: A 3-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 60 °C 175 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (500 V) 55 °C 130 A | (690 V) 55 °C 80 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 140 A | (440 V) 60 °C 140 A | (500 V) 60 °C 130 A | (690 V) 60 °C 80 A | (380 / 400 V) 60 °C 140 A | (220 / 230 / 240 V) 60 °C 140 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 175 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 175 A | (110 V) 3 Poles in Series, 70 °C 160 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 175 A | (175 V) 2 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 175 A | (220 V) 3 Poles in Series, 70 °C 160 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 175 A | (260 V) 3 Poles in Series, 70 °C 160 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 175 A | (72 V) 1-Pole, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 175 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 175 A | (72 V) 3 Poles in Series, 70 °C 160 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 175 A | (90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Power Loss
9 W | at Rated Operating Conditions per Pole 9 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
General Use Rating UL/CSA
(600 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 120 A | (220 ... 240 V AC) Three Phase 130 A | (440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511428
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210354
Feature → Business Impact → Application: Three main normally open contacts in a 3P configuration with two NO and two NC auxiliary contacts enables compact yet versatile control of motor start/stop and interlocking sequences in rail traction equipment. This translates to safer, smoother starts and easier fault isolation in locomotion and passenger-car subsystems.Feature → Business Impact → Application: Coil control voltage across 24–60 V AC, 50/60 Hz or 20–60 V DC provides flexible integration with diverse control architectures, reducing wiring complexity and compatibility issues during upgrades or retrofits in rail plants.Feature → Business Impact → Application: Rated operational voltage up to 1000 V and power ratings up to 75 kW AC-3 across common rail voltages support high-load motor control, enabling reliable traction and auxiliary drive duties with fewer devices in the cabinet.Feature → Business Impact → Application: Mechanical durability of 5 million cycles and a maximum switching frequency of 300 cycles per hour deliver long service life in frequent-stop/start scenarios, lowering maintenance and replacement costs for rail installations.Feature → Business Impact → Application: Compliance with environmental and safety standards (RoHS, REACH, EPD, EN 50155, UL/CSA) simplifies procurement, regulatory filings, and end-of-life recycling, aligning with ABB EcoSolutions and sustainability goals across rail projects.Feature → Business Impact → Application: Robust data and material declarations (CMRT, TSCA, WEEE) and verified certifications support risk management, audits, and supply-chain resilience for rail customers needing traceable product provenance.
Get a Quick Quote for a ABB 1SFL447063R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL447063R1122?
Enquire Now
FAQs
The device supports 50/60 Hz 24–60 V AC and 20–60 V DC coil control, while the main circuit is rated up to 1000 V and accommodates up to 690 V systems, enabling seamless integration with rail control architectures and variable-speed drives.
AC-3 ratings include 140 A at 415–690 V, with additional values at 380/400 V and 220/230/240 V ranges. DC-3 ratings cover combinations such as 110 V configurations with 160 A in two or three-pole series arrangements, ensuring reliable motor control for traction and auxiliary loads.
Yes. It is designed for railway applications, featuring three main NO contacts, suitable auxiliary contacts for interlocking, and a 690 V capability, along with rail-specific certifications (EN/IEC standards) to support motor starting, isolation, bypass, and distribution tasks.
Key standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1/2 for applicable parts, EN 50155, and TR CU 001/2011, with additional CE/UKCA declarations and EAC where required for rail and industrial applications.
With a mechanical durability of about 5 million cycles and a maximum switching rate of 300 cycles per hour, the unit delivers extended service life and lower maintenance costs. Energy-efficient operation, RoHS/REACH compliance, and ABB EcoSolutions support contribute to lower lifecycle costs and easier compliance auditing.