ABB 1SFL447063R1322 Block Contactor - IEC 60947-4-1
Part Number: 1SFL447063R1322
Quick Summary
ABB 1SFL447063R1322 Block Contactor is a high-current switch for motor starting in railway applications. Maintenance downtime and inconsistent control voltages can drive up repair costs and operational delays. It complies with IEC/EN 60947-4-1 and UL 60947-4-1, plus EN 50155 for rail use, ensuring safe, certified operation in demanding environments. This device integrates seamlessly with ABB’s control ecosystem, offering robust electrical protection and circuit control capabilities, while delivering reliable performance in rail and industrial applications, enabling scalable, cost-efficient protection architecture.
Product Information
Extended Description
1SFL447063R1322 ABB: A 3-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, 50 /60 Hz and DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 60 °C 175 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (500 V) 55 °C 130 A | (690 V) 55 °C 80 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 140 A | (440 V) 60 °C 140 A | (500 V) 60 °C 130 A | (690 V) 60 °C 80 A | (380 / 400 V) 60 °C 140 A | (220 / 230 / 240 V) 60 °C 140 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 175 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 175 A | (110 V) 3 Poles in Series, 70 °C 160 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 175 A | (175 V) 2 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 175 A | (220 V) 3 Poles in Series, 70 °C 160 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 175 A | (260 V) 3 Poles in Series, 70 °C 160 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 175 A | (72 V) 1-Pole, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 175 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 175 A | (72 V) 3 Poles in Series, 70 °C 160 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 175 A | (90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss
9 W | at Rated Operating Conditions per Pole 9 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
General Use Rating UL/CSA
(600 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 120 A | (220 ... 240 V AC) Three Phase 130 A | (440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511404
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210356
Feature → Business Impact → Application: The 3-pole design with 3 NO main contacts and 2 NO/NC auxiliary contacts delivers compact power switching for motor starting and isolation up to 690 V, reducing wiring complexity and cabinet space, which translates to lower installation costs and easier service in rail traction or distribution panels. Feature → Business Impact → Application: A wide control voltage range of 100-250 V AC/60 Hz or DC enables a single part to interface with diverse control systems, simplifying stock, accelerating commissioning, and improving reliability across signaling and protection circuits in challenging environments. Feature → Business Impact → Application: Rated AC-3 up to 140 A at 415–690 V and AC-3e up to 140 A provide robust starting and running capacity for medium-to-large motors, reducing drive wear and smoothing load transitions in traction drives and heavy-duty substations. Feature → Business Impact → Application: Mechanical durability of 5 million cycles and a practical switching rate of 300 cycles per hour extend service intervals and lower maintenance costs, delivering predictable lifecycle performance for critical rail and industrial loads. Feature → Business Impact → Application: UL/CSA, CE, EN 50155 and related environmental certifications give customers regulatory confidence, easing procurement audits and speeding up compliance in rail yards, factory floors, and protected outdoor installations. Feature → Business Impact → Application: Compact footprint with 90 mm width, 126 mm depth, 150 mm height and 1.55 kg weight, plus bar-type main terminals, simplifies panel design, enables quick installation, and supports retrofit into existing ABB or third-party switchgear.
Get a Quick Quote for a ABB 1SFL447063R1322
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL447063R1322?
Enquire Now
FAQs
For rail installations, mount the 3P Block Contactor using the provided bar terminals with appropriate clearance. Ensure the coil is supplied within 100-250 V AC/50/60 Hz or DC, and verify the main circuit rating up to 1000 V. Plan cabling to accommodate the 90 mm width and 126 mm depth for compact panel layouts.
The contactor supports AC-3 operation up to 140 A at 415 V (and related voltages up to 690 V), with AC-3e ratings matching 140 A under similar conditions. It delivers a rated breaking capacity of 8 x Ie and a making capacity of 10 x Ie, suitable for motor starting and load isolation in demanding environments.
Yes. It is designed for rail use and carries EN 50155 applicability, along with IEC/EN 60947-4-1 and UL 60947-4-1 compliance. Its 3P configuration with 3 main NO contacts and 2 NO/NC auxiliaries supports reliable switching for traction drives, distribution panels, and protection circuits in rail networks.
The device adheres to IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, EN 50155, and related certifications. These ensure electrical safety, electromagnetic compatibility, and reliability in rail and industrial settings, facilitating procurement approvals, reducing compliance risk, and enabling worldwide compatibility for integrators and OEMs.
With a mechanical durability of 5 million cycles and a maximum switching rate of 300 cycles per hour, maintenance intervals are extended and downtime is minimized. The rugged build, energy-conscious coil design, and ABB EcoSolutions backing contribute to lower total cost of ownership through fewer replacements and stable performance across service life.