ABB 1SFL447063R1422 Contactor - IEC 60947-4-1
Part Number: 1SFL447063R1422
Quick Summary
ABB 1SFL447063R1422 Contactor handles motor starting and isolation in rail applications up to 690 V. Rail projects often face reliability and control challenges amid voltage swings and tight panel space. It meets IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1 and EN 50155 among other standards, ensuring rail and industrial compliance. With a compact 90 mm width and 150 mm height, plus 3 main NO contacts and 2 NO/2 NC auxiliaries, it combines versatility with robust performance. The device delivers dependable operation, a manageable weight of 1.55 kg, and lifecycle reliability that helps reduce maintenance and lifecycle costs for rolling stock control systems.
Product Information
Extended Description
1SFL447063R1422 ABB: A 3-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 250-500 V, 50 /60 Hz and DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 60 °C 175 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (500 V) 55 °C 130 A | (690 V) 55 °C 80 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 140 A | (440 V) 60 °C 140 A | (500 V) 60 °C 130 A | (690 V) 60 °C 80 A | (380 / 400 V) 60 °C 140 A | (220 / 230 / 240 V) 60 °C 140 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 175 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 175 A | (110 V) 3 Poles in Series, 70 °C 160 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 175 A | (175 V) 2 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 175 A | (220 V) 3 Poles in Series, 70 °C 160 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 175 A | (260 V) 3 Poles in Series, 70 °C 160 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 175 A | (72 V) 1-Pole, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 175 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 175 A | (72 V) 3 Poles in Series, 70 °C 160 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 175 A | (90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Average Pull-in Value 50 Hz 260 V·A | Average Pull-in Value 60 Hz 260 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
9 W | at Rated Operating Conditions per Pole 9 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
General Use Rating UL/CSA
(600 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 120 A | (220 ... 240 V AC) Three Phase 130 A | (440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511398
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210430
Feature: Three-pole block contactor with 3 main NO contacts and 2 NO/2 NC auxiliary contacts → Business Impact: Expands control logic and interlock options while maintaining compact footprint → Application: Rail motor starting, isolation, distribution in space-constrained panels. Feature: Wide control voltage range 250–500 V (AC/DC) with measured coil consumption values → Business Impact: Simplifies control wiring and compatibility with diverse signaling systems, reducing spare parts and installation time → Application: Rail control cabinets and centralized drive interfaces requiring flexible coil operation. Feature: Rated Operational Current AC-3 up to 140 A at 415–440–500 V and 80 A at 690 V; AC-1 up to 200 A at 690 V → Business Impact: Capable of handling heavy motor loads and frequent switching without sacrificing reliability → Application: Traction motor starters, auxiliary power distribution, and load switching in rail vehicles. Feature: Rated Power AC-3 / AC-3e up to 75 kW at higher voltages and 37 kW at 220–240 V → Business Impact: Supports scalable drive configurations and energy-efficient motor control → Application: High-power rail conveyors, fans, and pump circuits within safe operating margins. Feature: Mechanical Durability of 5 million cycles and maximum switching frequency of 300 cycles per hour → Business Impact: Lower maintenance costs and reduced downtime in mission-critical rail environments → Application: Continuous duty control sequences and safety interlocking in locomotives and trams. Feature: Robust packaging with 90 mm width, 126 mm depth, 150 mm height and 1.55 kg weight; Main Circuit: Bars → Business Impact: Space-efficient, easy integration into standard rail control panels and harness routing → Application: OEM rail subsystems and retrofit projects requiring compact, reliable contactors. Feature: Compliance with IEC/EN 60947-1, 60947-4-1; UL/CSA and EN 50155 and other standards → Business Impact: Ensures regulatory conformity across markets, accelerating procurement and site approvals → Application: Global rail applications and mixed-technology installations requiring certified protection and control components.
Get a Quick Quote for a ABB 1SFL447063R1422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL447063R1422?
Enquire Now
FAQs
This 3P block contactor uses main circuit bars for the primary connections and supports a compact footprint (90 mm W x 126 mm D x 150 mm H) with a weight of 1.55 kg. It features 3 NO main contacts and 2 NO / 2 NC auxiliary contacts, suitable for rail panels that require reliable control wiring and flexible interlocking. Ensure wiring adheres to applicable standards and that coil control voltage is within 250–500 V (AC/DC).
For AC-3 operation, the contactor provides up to 140 A at 415–440–500 V, and up to 80 A at 690 V. Rated power AC-3 reaches 75 kW at the higher voltages and 37 kW at 220–240 V. These ratings support motor starting and reliability in rail drive applications while sustaining safe thermal margins.
Yes. With 3 main NO contacts and auxiliary contacts, a robust coil range of 250–500 V, and 75 kW AC-3 power rating at main voltages, it is well-suited for motor starting, isolation, bypass and distribution tasks in railway and rigorous industrial contexts, delivering dependable operation under fluctuating rail power conditions.
The device complies with IEC/EN 60947-1 and 60947-4-1, UL 60947-4-1, CSA C22.2, EN 50155 for railway relevance, IEC 60077-1/2 for applicable parts, TR CU 001/2011, and IEC 61373 for vibration. It also carries EAC, UL/CSA listings and related certificates for global deployment.
The AF140B contactor delivers 5 million mechanical durability cycles and a maximum switching frequency of 300 cycles per hour, reducing downtime and maintenance costs. Its wide coil voltage tolerance and compact form factor simplify stocking and installation, delivering long-term ROI through fewer field failures and easier retrofits in rail systems.