ABB 1SFL447263R1322 Contactor - CE UL Listed 4P

Part Number: 1SFL447263R1322
Manufacturer
ABB
Part number
1SFL447263R1322

Quick Summary

ABB 1SFL447263R1322 Contactor provides reliable motor starting and isolation for rail and industrial drives. When panel space is tight and reliability matters, engineers need rugged performance that reduces wiring time and maintenance. With CE, UL/CSA, and UKCA certifications, plus RoHS and REACH compliance, this block contactor supports global deployments. Designed for 4 poles with two auxiliary contacts, it streamlines control wiring while delivering consistent electrical performance. This combination of compact footprint, high current ratings, and broad voltage compatibility translates into lower installation costs and longer service intervals for rail and automation projects.

Product Information

Extended Description

1SFL447263R1322 ABB: A 4-pole Contactor suitable for Railway applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 100-250 V, 50 /60 Hz and DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
120 mm
Product Net Depth / Length
128 mm
Product Net Height
150 mm
Product Net Weight
2.05 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 60 °C 175 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 175 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 175 A | (110 V) 3 Poles in Series, 70 °C 160 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 175 A | (175 V) 2 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 175 A | (220 V) 3 Poles in Series, 70 °C 160 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 175 A | (260 V) 3 Poles in Series, 70 °C 160 A | (350 V) 4 Poles in Series, 40 °C 200 A | (350 V) 4 Poles in Series, 60 °C 175 A | (350 V) 4 Poles in Series, 70 °C 160 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 175 A | (72 V) 1-Pole, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 175 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 175 A | (72 V) 3 Poles in Series, 70 °C 160 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 175 A | (90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Power Loss
18 W | at Rated Operating Conditions per Pole 18 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
General Use Rating UL/CSA
(600 V AC) 175 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp | (200 V AC) Three Phase 40 hp | (208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 20 Hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 40 Hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 50 Hp | (550 ... 600 V AC) Three Phase 125 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
CB Certificate
SEMKO_SE-77317
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF116-40...AF140-40 (Sweden)
UL Certificate
cULus Certificate, Contactor, AF116-40, AF140-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
197 mm
Package Level 1 Height
155 mm
Package Level 1 Gross Weight
2.25 kg
Package Level 1 EAN
7320500511367
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210466
Feature → Business Impact → Application: Four-pole main contacts (NO) enable robust motor starting and power distribution with a single device, reducing panel complexity and wiring hours in railway control cabinets. Result: lower installation costs and improved reliability in demanding environments. Application: Control circuits with a wide coil voltage range (100-250 V AC/DC) simplify integration with existing automation architectures and spare part stocking. Result: faster commissioning and easier maintenance across varying supply conditions. Feature → Business Impact → Application: Two auxiliary NO and two NC contacts support interlocking and feedback circuits, improving safety interlocks and fault monitoring. Result: enhanced system integrity for traction and distribution panels. Application: High voltage up to 1000 V main circuit and current ratings up to 200 A AC-1, 140 A AC-3 at industrial voltages. Result: capability to handle motor loads and start/stop sequences with confidence. Feature → Business Impact → Application: Rugged construction and 5 million mechanical cycles offer longevity in heavy-duty rail switching and continuous operation scenarios. Result: reduced replacement cycles and lower total cost of ownership. Application: Rail signaling and industrial drives where dependable switching is critical. Feature → Business Impact → Application: Wide operating and protection range, including 690 V applications and by-pass/isolation capabilities. Result: flexible deployment across multiple line sections and retrofit opportunities. Application: OEMs integrating into standardized control enclosures and modular rail systems.

Get a Quick Quote for a ABB 1SFL447263R1322

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL447263R1322? Enquire Now

FAQs

Yes. This device is a four-pole block contactor designed for rail applications and uses main circuit bars for robust, easy-to-wire connections. It supports space-efficient panel layouts and standard mounting arrangements, reducing wiring complexity and installation time in rail control cabinets.
For AC-1, at 690 V and 40 °C it is 200 A, with 60 °C 175 A and 70 °C 160 A. For AC-3, at 415 V and 55 °C it is 140 A, with similar ratings at other standard voltages. These ratings cover typical motor starting and distribution loads in industrial and railway settings.
Yes. The 1SFL447263R1322 is specified for motor starting, isolation, by-pass, and distribution in railway applications, with 4 main NO contacts and auxiliary contacts to support interlocking and feedback circuits, ensuring reliable operation in demanding rail environments.
This model carries CE, UL/CSA, and UKCA certifications, along with RoHS and REACH compliance, enabling global market access and alignment with regulatory requirements across Europe, North America, and the UK.
With a mechanical durability rating of 5 million cycles and a maximum switching frequency of 300 cycles per hour, the device offers long service life and predictable maintenance intervals. This reduces downtime, supports higher mean time between failures, and lowers total cost of ownership for rail and industrial automation projects.