ABB 1SFL447263R1422 Contactor - UL/CSA 4P 690V AC-3

Part Number: 1SFL447263R1422
Manufacturer
ABB
Part number
1SFL447263R1422

Quick Summary

ABB 1SFL447263R1422 Contactor is a reliable motor starting device designed for industrial drives and isolation up to 1000 V. Engineers often struggle with retrofit wiring, limited panel space, and maintaining control circuit compatibility during upgrades. This model carries CE and UKCA conformity, UL/cUL safety listings, KC and CCC certifications, plus RoHS and REACH compliance to support global deployments. Together, these features translate into easier installation, lower lifecycle costs, and safer, more reliable motor protection for demanding industrial environments.

Product Information

Extended Description

1SFL447263R1422 ABB: A 4-pole contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with 250 ... 500 V, 50Hz/60Hz and DC. Equipped with 2 N.O and 2 N.C. auxiliary contacts.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
120 mm
Product Net Depth / Length
128 mm
Product Net Height
150 mm
Product Net Weight
2.05 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 200 A | (690 V) 60 °C 175 A | (690 V) 70 °C 160 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 140 A | (440 V) 55 °C 140 A | (380 / 400 V) 55 °C 140 A | (220 / 230 / 240 V) 55 °C 140 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 175 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 175 A | (110 V) 3 Poles in Series, 70 °C 160 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 175 A | (175 V) 2 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 175 A | (220 V) 3 Poles in Series, 70 °C 160 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 175 A | (260 V) 3 Poles in Series, 70 °C 160 A | (350 V) 4 Poles in Series, 40 °C 200 A | (350 V) 4 Poles in Series, 60 °C 175 A | (350 V) 4 Poles in Series, 70 °C 160 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 175 A | (72 V) 1-Pole, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 175 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 175 A | (72 V) 3 Poles in Series, 70 °C 160 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 175 A | (90 V) 1 Pole, 70 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (110 V) 2 Poles in Series, 60 °C 160 A | (110 V) 2 Poles in Series, 70 °C 160 A | (110 V) 3 Poles in Series, 40 °C 160 A | (110 V) 3 Poles in Series, 60 °C 160 A | (110 V) 3 Poles in Series, 70 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 60 °C 160 A | (220 V) 3 Poles in Series, 70 °C 160 A | (72 V) 2 Poles in Series, 40 °C 160 A | (72 V) 2 Poles in Series, 60 °C 160 A | (72 V) 2 Poles in Series, 70 °C 160 A | (72 V) 3 Poles in Series, 40 °C 160 A | (72 V) 3 Poles in Series, 60 °C 160 A | (72 V) 3 Poles in Series, 70 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 37 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Average Pull-in Value 50 Hz 260 V·A | Average Pull-in Value 60 Hz 260 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
18 W | at Rated Operating Conditions per Pole 18 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
4
Continuous Current Rating NEMA
135 A
Horsepower Rating NEMA
(200 V AC) Three Phase 40 Hp | (230 V AC) Three Phase 50 Hp | (460 V AC) Three Phase 100 Hp | (575 V AC) Three Phase 100 Hp
General Use Rating UL/CSA
(600 V AC) 175 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp | (200 V AC) Three Phase 40 hp | (208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 20 Hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 40 Hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 50 Hp | (550 ... 600 V AC) Three Phase 125 hp
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
CB Certificate
SEMKO_SE-77317
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF116-40...AF140-40 (Sweden)
UL Certificate
cULus Certificate, Contactor, AF116-40, AF140-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
197 mm
Package Level 1 Height
155 mm
Package Level 1 Gross Weight
2.25 kg
Package Level 1 EAN
7320500511350
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210467
Feature: 4P block design with 4 main NO contacts and 2 NO plus 2 NC auxiliary contacts creates a compact yet powerful control element. Business impact: This configuration enables direct, reliable motor starting and integrated status feedback, reducing external interconnects and potential failure points in conveyors, pumps, and mixers. Application: Suitable for heavy-duty applications where space is tight and wiring must be minimized. Feature: Main circuit rated up to 1000 V with Ie up to 200 A at 40 C (AC-1) and 140 A at AC-3 for 415-440 V. Business impact: Higher voltage rating expands safe use in multi-voltage systems, lowering mis-wiring risk and speeding up panel design. Application: Industrial drives, fans, and pumps operating at higher voltages. Feature: Coil voltage range 250 to 500 V for AC or DC operation; coil consumption values provide efficient energization. Business impact: Flexible integration with existing control systems and reduced coil power draw during holding. Application: Retrofits and new installs where control circuits vary or upgrade cycles are planned. Feature: Mechanical durability rated at 5 million cycles and a maximum switching frequency of 300 cycles per hour. Business impact: Long service life and predictable maintenance schedules reduce downtime and replacement costs. Application: Continuous processes in packaging, material handling, and process automation. Feature: Main terminals are bars with compact dimensions (120 mm wide, 128 mm deep, 150 mm high) and a weight of 2.05 kg. Business impact: Easy mounting and integration into standard switchgear footprints; reduces panel rework and simplifies transport. Application: New installations in control cabinets and retrofit projects with space constraints. Feature: ABB EcoSolutions and wide certification coverage (CE, UKCA, UL/cUL, KC, CCC, EAC), plus RoHS and REACH compliance. Business impact: Regulatory readiness and sustainability support, enabling global deployment with less documentation overhead. Application: Global manufacturing lines seeking compliant, energy-aware motor protection.

Get a Quick Quote for a ABB 1SFL447263R1422

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL447263R1422? Enquire Now

FAQs

Yes. The device supports a control circuit voltage range of 250 to 500 V for both AC and DC operation, with 50 Hz or 60 Hz supply. Coil consumption values are provided for pull-in and hold, enabling accurate matching to existing control systems and minimizing energy use during operation.
The unit features four main normally open (NO) contacts for the power path, and two normally open plus two normally closed auxiliary contacts. This configuration provides integrated feedback and control signaling while maintaining a compact footprint suitable for restricted panels and pre-wired enclosures.
The contactor carries CE and UKCA declarations, UL/cUL safety listings, KC and CCC certifications, along with RoHS and REACH compliance. It also aligns with WEEE guidance for business-to-business applications, supporting global deployments and regulatory readiness.
AC-1 current rating at 690 V is up to 200 A (40 °C). AC-3 current rating at 415/440 V is 140 A, and it remains 140 A across 380–400 V and 220–240 V variants. Ratings vary slightly with temperature, ensuring safe operation across typical industrial environments.
The contactor uses bar-type main terminals for straightforward wiring, with Dimensions 120 mm width, 128 mm depth, 150 mm height and a weight of 2.05 kg for easy handling. Its mechanical durability of 5 million cycles and a max switching frequency of 300 cycles/hour reduce downtime and maintenance costs in continuous processes.