ABB 1SFL457062R6911 Block Contactor - CE/UL Cert

Part Number: 1SFL457062R6911
Manufacturer
ABB
Part number
1SFL457062R6911

Quick Summary

ABB 1SFL457062R6911 Block Contactor is a versatile rail-ready switching device designed to handle three-pole power switching with a wide coil range of 48–130 V. This model addresses the common challenge of panel space and compatibility across varying control voltages, reducing the need for multiple relays in mixed voltage environments. It carries critical certifications such as IEC/EN 60947-4-1, UL 60947-4-1, and CE marking, ensuring safety, interoperability, and regulatory compliance in rail and industrial applications. The combination of robust construction, reliable AC-3 performance, and a compact footprint supports efficient installation in modern automation lines while aligning with ABB’s commitment to quality and serviceability.

Product Information

Extended Description

1SFL457062R6911 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 48-130 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL427062R1222
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
Dimension Diagram
1SFB535001G1005
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 55 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 110 A | (440 V) 55 °C 100 A | (500 V) 55 °C 100 A | (690 V) 55 °C 82 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 110 A | (220 / 230 / 240 V) 55 °C 110
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 59 kW | (440 V) 59 kW | (500 V) 59 kW | (690 V) 75 kW | (1000 V) 40 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 2 x 6 ... 65 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Ring-Tongue Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 140 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
13409/C0 BV
CB Certificate
SE-73663
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LOVAG Certificate
SE-0145185
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500260142
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: The coil control voltage range of 48–130 V AC/DC eliminates the need for multiple coil variants, reducing stocking complexity and enabling faster commissioning in control panels. This translates to lower total cost of ownership and improved system uptime in urban rail or industrial automation deployments. Feature → Business Impact → Application: With 3 main NO contacts and 1 NO + 1 NC auxiliary contact, the device provides flexible control of motors and signaling circuits, enabling precise sequencing and safe isolation in high-demand drives and conveyors. Feature → Business Impact → Application: Rated operational current AC-3 up to 110 A at various voltages (e.g., 415 V and 690 V) supports common traction and machine controls, improving equipment utilization and reducing fault-related downtime. Feature → Business Impact → Application: Insulation voltage of 1000 V and impulse withstand of 8 kV enhance protection against surge events, increasing reliability in harsh industrial environments. Feature → Business Impact → Application: Mechanical durability of 10 million cycles and a maximum switching frequency of 300 cycles per hour offer longevity and predictable maintenance cycles for long-life applications. Feature → Business Impact → Application: Robust connections (M8 terminals, ring-tongue option) and a 8 N·m tightening torque simplify installation, ensure secure terminations, and minimize loose connections in dense control panels. Feature → Business Impact → Application: Compliance with IEC 60947-4-1, UL/CSA, and CE accelerates regulatory acceptance and OEM integration in railway and industrial control systems, reducing engineering time and accelerating time-to-market.

Get a Quick Quote for a ABB 1SFL457062R6911

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL457062R6911? Enquire Now

FAQs

The device uses M8 hexagon socket screws for main pole connections and provides ring-tongue terminals for a secure, vibration-resistant fit. Tightening torque for the main circuit is 8 N·m. Mounting should follow standard panel layouts with adequate clearance for heat dissipation and clear labeling of coil voltage (48–130 V) and line connections to ensure safe operation.
The coil operates at 48–130 V for both 50 Hz and 60 Hz, with DC operation in the same range. Main circuit ratings include up to 1000 V insulation and AC-3 current up to 110 A (at 415 V, 55 °C) to 82 A (at 690 V, 55 °C). It also provides 3 NO main contacts and 1 NO + 1 NC auxiliary contact for flexible control schemes.
Yes. The contactor is designed for rail applications and supports standards such as IEC/EN 60947‑4‑1 and related rail references. It carries CE, UL/CSA readiness, and additional certifications aligned with railway safety requirements, enabling reliable performance in signaling, traction, and auxiliary control circuits.
The device complies with IEC 60947‑4‑1, UL 60947‑4‑1, and CE, with a broad portfolio of certificates including CB, BV, GL, LR, RINA, ABS, EAC, RMRS, and CCC. This extensive certification set supports global deployments and OEM integrations in regulated industries.
With a mechanical durability of up to 10 million cycles, a maximum switching frequency of 300 cycles per hour, and robust protection ratings (IP20 coil terminals, IP10 main terminals), the unit minimizes unscheduled downtime and maintenance costs. The wide coil range reduces inventory, while high reliability translates to longer service intervals and improved fleet uptime.