ABB 1SFL457062R7011 Block Contactor - IEC 60947-4-1
Part Number: 1SFL457062R7011
Quick Summary
ABB 1SFL457062R7011 Block Contactor is a 3-pole control device designed for rail applications and heavy‑duty motor switching. Engineers often face control‑voltage compatibility and reliability challenges when deploying contactors in harsh environments. This model supports a wide control voltage range from 100 to 250 V AC, DC, enabling a single part to cover multiple supply standards and simplify stocking. It also carries essential certifications such as IEC/EN 60947-4-1 and IEC/EN 60947-1, UL 60947-4-1, and EN 50155 for railway relevance, plus CE and EAC compliance for global use. By combining robust electrical ratings with compact dimensions, it reduces panel space, lowers installation time, and improves maintenance predictability for fleet operators and contractors.
Product Information
Extended Description
1SFL457062R7011 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL427062R1322
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
Dimension Diagram
1SFB535001G1005
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 55 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 110 A | (440 V) 55 °C 100 A | (500 V) 55 °C 100 A | (690 V) 55 °C 82 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 110 A | (220 / 230 / 240 V) 55 °C 110
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 59 kW | (440 V) 59 kW | (500 V) 59 kW | (690 V) 75 kW | (1000 V) 40 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 1 x 10 ... 95 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Ring-Tongue Terminals
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 140 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
13409/C0 BV
CB Certificate
SE-73664
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LOVAG Certificate
SE9831016
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500260159
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Norway)
4115321
Feature wide control voltage range 100-250 V AC/DC → Business Impact simplifies procurement and stocking, enabling a single part to cover multiple supply standards; Application rail traction systems and heavy‑duty conveyors. Application 3NO main contacts with 1 NO and 1 NC auxiliary → Business Impact expands functionality within limited enclosure space; Application control circuits requiring an auxiliary path. Feature rated insulation voltage up to 1000 V and impulse withstand voltage of 8 kV → Business Impact enhances high‑voltage safety margins and reliability in demanding environments; Application compliant with IEC 60947‑4‑1 and UL/CSA standards for global deployment. Feature mechanical durability up to 10 million cycles and a maximum mechanical switching frequency of 300 cycles/hour → Business Impact reduces maintenance downtime and extends the service life in high‑demand applications; Application suitable for continuous operation in rail and industrial settings. Feature compact dimensions (102 mm width, 123.5 mm depth, 148 mm height) and a weight of 1.9 kg → Business Impact enables easier panel integration and weight budgeting; Application ideal for retrofit projects and new builds with tight spaces. Feature flexible connection options main circuit (bar 30 mm², 2x6...35 mm² flexible, 1x10...95 mm² rigid) and auxiliary circuit (range of ferrule and solid wire sizes) → Business Impact simplifies field wiring and reduces installation time; Application supports diverse wiring practices and devices. Feature IP20 coil terminals and IP10 main terminals along with M8 terminal screws → Business Impact improves protection against dust and incidental contact; Application ensures safer, faster commissioning in control panels. Feature rail‑oriented certifications (CE, UL/CSA, EN 50155, CCC, EAC) → Business Impact supports regulatory compliance across markets; Application accelerates project approvals and supplier audits.
Get a Quick Quote for a ABB 1SFL457062R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL457062R7011?
Enquire Now
FAQs
This ABB block contactor supports main circuit connections up to Bar 30 mm² and flexible cables from 2x6 to 35 mm², plus rigid 1x10 to 95 mm². Use M8 hexagon socket screws for secure terminal connections, and select ring‑tongue or ferrule terminations as required by your panel standards.
AC-3 ratings vary by voltage: up to 110 A at 415 V, 100 A at 440–500 V, 82 A at 690 V, and 30 A at 1000 V. For DC-3, operation is rated at 160 A for 110–220 V systems (two or three poles in series). These figures enable reliable motor starting and switching with diverse supply conditions.
Yes. It is designed for rail applications and is listed under EN 50155 applicability for applicable parts, with supporting IEC/EN 60947-1 and 60947-4-1 compliance. The device also presents robust insulation and impulse withstand ratings suitable for rolling stock and trackside equipment.
Key certifications include CE, UL/CSA, CCC, EAC, BV, ABS, GL, LR, RINA, and RMRS as listed in the product data. Verify CCC and CE declarations for the target region, UL/CSA for North America, and EN 50155 for rail standards to ensure full compliance in your assembly.
With a mechanical durability of 10 million cycles and a 0.25–0.5% incremental energy loss per operation, this contactor reduces maintenance downtime and replacement frequency. Its wide coil voltage tolerance reduces stocking requirements, while robust insulation and protection ratings minimize field failures in demanding environments.