ABB 1SFL457063R7211 Block Contactor - CE UL/CSA
Part Number: 1SFL457063R7211
Quick Summary
ABB 1SFL457063R7211 is a 3-pole block contactor designed for rail applications with a 20–60 V DC control voltage. Engineers face challenges with limited coil options and tight control panel spaces, and this device addresses both by offering a compact footprint and a wide DC control range. It carries CE and UL/CSA certifications, along with CB and CCC declarations, to support global deployment. For system integrators, the unit delivers reliable switching and robust thermal performance under demanding conditions, helping reduce downtime and streamline maintenance while enabling scalable control in industrial and railway environments.
Product Information
Extended Description
1SFL457063R7211 ABB: A 3-phase Contactor suitable for Rail way applications application. Operated with a wide voltage control voltage range 20-60V, DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL427063R1122
Data Sheet, Technical Information
1SBC100192C0206
Instructions and Manuals
Contactors A95, A110, UA95, UA110, AF95, AF110, AE95, AE110, TAE95, TAE110
Dimension Diagram
53540923-8
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A | (690 V) 55 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 110 A | (440 V) 55 °C 100 A | (500 V) 55 °C 100 A | (690 V) 55 °C 82 A | (1000 V) 55 °C 30 A | (380 / 400 V) 55 °C 110 A | (220 / 230 / 240 V) 55 °C 110
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A | (220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)
(415 V) 59 kW | (440 V) 59 kW | (500 V) 59 kW | (690 V) 75 kW | (1000 V) 40 kW | (380 / 400 V) 55 kW | (220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 160 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A | Holding at Max. Rated Control Circuit Voltage DC 2 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
at Rated Operating Conditions per Pole 3.5 W
Operate Time
Between Coil De-energization and NC Contact Closing 60 ... 130 ms | Between Coil De-energization and NO Contact Opening 55 ... 125 ms | Between Coil Energization and NC Contact Opening 27 ... 77 ms | Between Coil Energization and NO Contact Closing 30 ... 80 ms
Connecting Capacity Main Circuit
Bar 30 mm² | Flexible with Cable End 1 x 10 ... 70 mm² | Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 30 mm² | Flexible with Cable End 2 x 6 ... 35 mm² | Rigid 2 x 6 ... 65 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Tightening Torque
Main Circuit 8 N·m
Terminal Type
Cable Clamp
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 140 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp | (208 V AC) Three Phase 30 hp | (220 ... 240 V AC) Three Phase 40 hp | (440 ... 480 V AC) Three Phase 75 hp | (550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 96 A | (550 ... 600 V AC) Three Phase 99 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Information
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
RoHS Status
Following EU Directive 2011/65/EU
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
BV Certificate
13409/C0 BV
CB Certificate
SE-73668
CQC Certificate
CQC Certificate, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF95, AF95...RT, AF95B...RT, AF110, AF110...RT, AF110B...RT, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - A(F)95...A(F)300, AM110...AM300, UA95...UA110, (T)AE95....(T)AE110
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20260-04HH
LOVAG Certificate
SE9831016
LR Certificate
LR_04-00015-E1
RINA Certificate
ELE060313XG/002
RMRS Certificate
RMRS_12-03683-315
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Depth / Length
265 mm
Package Level 1 Height
162 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500256480
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature 1: DC coil control from 20 to 60 V enables flexible interfacing with low- and medium-voltage control circuits, reducing wiring complexity and enabling faster startup sequences. Business impact: lowers control panel wiring costs and minimizes power supply diversity; application: suitable for DC control rails and traction-related auxiliary systems. Feature 2: Three main NO contacts plus one NO and one NC auxiliary contact provide both switching and feedback signals within a single device, improving control reliability and simplifying logic interconnections. Business impact: reduces component count and wiring errors; application: motor drive start/stop and signaling circuits. Feature 3: Rated operational current and voltage (main circuit up to 1000 V, Ie up to 160 A AC-1/AC-3) support a broad range of motor loads and contactor duty cycles, with appropriate fusing and protection. Business impact: increases drive compatibility and minimizes replacement cycles; application: AC-3 motor control and DC traction circuits. Feature 4: Mechanical durability rated at 10 million cycles and a steady mechanical switching frequency of 300 cycles per hour deliver long service life in high-usage environments. Business impact: lowers maintenance costs and extends interval between replacements; application: production lines and rail signaling housings. Feature 5: Robust environmental and mounting features, including IP20 coil terminals and secure terminal connections with M8 screws, ensure reliable operation in panels and cabinets. Business impact: simplifies installation and reduces wiring issues; application: compact control cabinets and rolling stock enclosures. Feature 6: Comprehensive certifications (CE, UL/CSA, CCC, CB, BV, GL, etc.) provide regulatory confidence across international deployments. Business impact: accelerates approvals and compliance reporting; application: global industrial and railway installations.
Get a Quick Quote for a ABB 1SFL457063R7211
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL457063R7211?
Enquire Now
FAQs
The unit uses a DC coil rated 20–60 V with three main NO contacts and one NO plus one NC auxiliary contact. Connect the main circuit to the M8 terminal block using the appropriate conductor sizes (30 mm² for bar, 2 x 6…35 mm² for flexible cables) and secure auxiliaries with 0.75–2.5 mm² Ferrule or equivalent as specified. Torque the main terminals to 8 N·m and follow standard control wiring practices to avoid coil misfires. This ensures reliable pull-in and release in rail signaling and drive applications.
Rated operational current for AC-3 is up to 110 A at 415–690 V and down to 82–100 A at other voltage points, with DC-3 ratings of 160 A for 110–220 V configurations. The contactor provides an AC-3 breaking capacity of up to 8 x Ie and a making capacity of 10 x Ie, with a main circuit insulation up to 1000 V and a short-circuit withstand of 8 kV. These specs support reliable motor control and circuit protection in industrial and railway environments.
Yes. It is specifically designed for rail applications with a DC coil control (20–60 V) and robust insulation up to 1000 V. Its 3P configuration, 160 A Ie rating, and mechanical durability of 10 million cycles align well with repetitive control tasks, signaling, and auxiliary drive circuits common in rail systems, while its compact footprint eases integration in constrained enclosures.
The device carries CE and UL/CSA certifications, along with CB and CCC declarations, which support global deployment. RoHS compliance is noted, and additional certificates such as BV, GL, LR, RINA, and EAC appear in the documentation, providing broad regulatory coverage for international projects.
With a mechanical durability rating of 10 million cycles and a high switching capacity, the contactor minimizes downtime and maintenance frequency in high-cycle environments. The wide coil voltage tolerance simplifies control wiring, reducing spare part diversity, while CE UL/CSA compliance accelerates procurement and reduces compliance risk, delivering lower total cost of ownership over time.