ABB AF146-30-22B-34 Contactor - UL/CSA 1000V CE
Part Number: 1SFL467002R3422
Quick Summary
ABB AF146-30-22B-34 Contactor is a robust motor starter for industrial motor control. It enables reliable start/stop of large 3‑phase motors up to 1000 V and 225 A, with pre-mounted auxiliary contacts for streamlined wiring. It addresses the common panel instability caused by voltage fluctuations by offering a wide control voltage range and built‑in surge protection. This device carries CE Declaration of Conformity, UL/cULus recognition, and CB safety listings, ensuring compliant deployments across global facilities. With compact block design and compatibility with add-on auxiliary blocks, it delivers scalable control while reducing panel space and installation time. For engineers seeking efficiency, reliability, and lower total cost of ownership, AF146 provides a proven, future‑proof solution.
Product Information
Extended Description
1SFL467002R3422 ABB: The AF146-30-22B-34 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
142.5 mm
Product Net Height
150 mm
Product Net Weight
1.3 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 225 A | (1000 V) 55 °C 200 A | (1000 V) 60 °C 200 A | (1000 V) 70 °C 175 A | (690 V) 40 °C 225 A | (690 V) 55 °C 200 A | (690 V) 60 °C 200 A | (690 V) 70 °C 175 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 146 A | (440 V) 55 °C 146 A | (500 V) 55 °C 130 A | (690 V) 55 °C 93 A | (1000 V) 55 °C 60 A | (380 / 400 V) 55 °C 146 A | (220 / 230 / 240 V) 55 °C 146 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 146 A | (440 V) 60 °C 146 A | (500 V) 60 °C 130 A | (690 V) 60 °C 93 A | (1000 V) 60 °C 54 A | (380 / 400 V) 60 °C 146 A | (220 / 230 / 240 V) 60 °C 146 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Short-Circuit Protective Devices
gG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 150 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Average Pull-in Value 50 Hz 260 V·A | Average Pull-in Value 60 Hz 260 V·A | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 230 W
Power Loss
at Rated Operating Conditions per Pole 10 W
Operate Time
Between Coil De-energization and NO Contact Opening 37 ... 47 ms | Between Coil Energization and NO Contact Closing 25 ... 55 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 15 Hp | (200 V AC) Three Phase 40 hp | (208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 20 Hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 40 Hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 50 Hp | (550 ... 600 V AC) Three Phase 125 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-70479M1
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV-certificate, Contactors, AF116-30...AF370-30 and AF116-40...AF370-40
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF146-30 (Sweden)
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.5 kg
Package Level 1 EAN
7320500480960
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: The AF146-30-22B-34 is a 3-pole block contactor rated for mains up to 1000 V and AC-3 operation, delivering reliable motor switching with 75 kW capacity at 415 V and 146 A at 415/440/480 V variants. This translates to high-speed, low‑conflict starts, reducing downtime and improving line productivity in conveyor systems and pumps. Application-ready with pre-mounted auxiliary contacts (NO/NO and NC variants) and main circuit bars, it simplifies control wiring and minimizes panel depth, saving assembly time and reducing panel costs in OEM and retrofits. The wide control circuit voltage range (250–500 V AC, 50/60 Hz, and DC) ensures resilient operation even in networks with voltage drift, cutting nuisance trips and maintenance needs. By supporting add-on accessories, you can tailor logic, signaling, and interlocking without replacing the base unit.
Get a Quick Quote for a ABB 1SFL467002R3422
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL467002R3422?
Enquire Now
FAQs
The AF146-30-22B-34 is a 3P block contactor designed for 3‑phase mains up to 1000 V and supports commonly used voltages such as 380/400 V, 415/440 V, and 480 V. It integrates main circuit bars and pre-mounted auxiliary contacts for straightforward wiring. For retrofits, verify enclosure space, available auxiliary contacts, and fit within the rated current (AC-3 up to 146 A at 415 V, 200–225 A at higher voltages) to ensure seamless installation and reliable operation.
This model provides AC-3e and AC-3 ratings suitable for motor switching tasks, with 75 kW at 415 V (AC-3) and up to 90 kW at certain voltages. The device supports a range of operating currents (I_e) from 60 A to 146 A depending on voltage and temperature, and is compatible with motors up to around 100 hp at 480 V. Always confirm exact current at your operating temperature and voltage.
Built‑in surge protection helps absorb transient voltage spikes common in unstable networks, reducing coil stress and preventing nuisance tripping. This improves reliability in applications with irregular power quality, such as conveyor lines or pumps in older facilities. With surge mitigation, maintenance intervals extend and panel energy consumption remains stable, contributing to lower operational costs over the life of the drive system.
The AF146 is designed with a block-type architecture that supports add‑on auxiliary contact blocks and a broader variety of accessories. This enables size/logic expansion, interlocking, and signaling options without replacing the base unit. Compatibility with standard ABB AF family accessories simplifies procurement, reduces spare parts inventory, and allows scalable control architecture as motor protection needs evolve.
The AF146-30-22B-34 carries CE declarations of conformity, UL/cULus certifications, and CB safety listings, among others. These certifications support compliance across European and North American markets, align with IEC/UL 60947 standards for contactors, and facilitate regulatory approvals during QA audits and customer projects. Always cross-check regional requirements to confirm full conformity for your installation site.