ABB AF146B-30-22RT-11 Contactor - IEC/UL 60947-4-1
Part Number: 1SFL467062R1122
Quick Summary
ABB AF146B-30-22RT-11 Contactor is a reliable motor starter designed for industrial pumps, fans, and conveyors. In practice, fluctuating control voltages and unstable networks can cause nuisance tripping and wasted energy; this AF technology addresses that by tolerating wide voltage variations while maintaining distinct, repeatable switching. The device carries key certifications such as IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60947-4-1, ensuring compliance across global markets. By combining a compact block design with pre-mounted auxiliary contacts and surge protection, the AF146B supports easy panel integration and scalable control architectures, delivering measurable business value through improved uptime and energy efficiency. This makes it a solid choice for OEMs and panel builders seeking robust performance with ready-for-assembly compatibility.
Product Information
Extended Description
1SFL467062R1122 ABB: The AF146B-30-22RT-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.3 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 225 A | (1000 V) 55 °C 200 A | (1000 V) 60 °C 200 A | (1000 V) 70 °C 175 A | (690 V) 40 °C 225 A | (690 V) 55 °C 200 A | (690 V) 60 °C 200 A | (690 V) 70 °C 175 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 146 A | (440 V) 55 °C 130 A | (500 V) 55 °C 130 A | (690 V) 55 °C 93 A | (1000 V) 55 °C 60 A | (380 / 400 V) 55 °C 146 A | (220 / 230 / 240 V) 55 °C 146 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 146 A | (440 V) 60 °C 146 A | (500 V) 60 °C 130 A | (690 V) 60 °C 93 A | (1000 V) 60 °C 54 A | (380 / 400 V) 60 °C 146 A | (220 / 230 / 240 V) 60 °C 146 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 200 A | (110 V) 2 Poles in Series, 70 °C 175 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 200 A | (110 V) 3 Poles in Series, 70 °C 175 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 200 A | (175 V) 2 Poles in Series, 70 °C 175 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 200 A | (220 V) 3 Poles in Series, 70 °C 175 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 200 A | (260 V) 3 Poles in Series, 70 °C 175 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 200 A | (72 V) 1-Pole, 70 °C 175 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 200 A | (72 V) 2 Poles in Series, 70 °C 175 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 200 A | (72 V) 3 Poles in Series, 70 °C 175 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 200 A | (90 V) 1 Pole, 70 °C 175 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 225 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Power Loss
10 W | at Rated Operating Conditions per Pole 10 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 120 A | (220 ... 240 V AC) Three Phase 130 A | (440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
cURus Certificate
cURus certificate, Contactor, AF116B..RT-AF146B-30...RT
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UR Certificate
cURus certificate, Contactor, AF116B..RT-AF146B-30...RT
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.5 kg
Package Level 1 EAN
7320500509890
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3-pole main circuit rated up to 1000 V and 225 A AC-1 at 40 °C. Business Impact: Handles demanding motor loads with reliable startup and running performance, reducing line faults and downtime. Application: Suitable for AC-1 motor control in process lines and packaging equipment. Feature: Wide control voltage range 24-60 V AC (50/60 Hz) and 20-60 V DC. Business Impact: Minimizes control circuit failures due to voltage swings, lowering panel energy waste and resetting events. Application: Ideal for systems with variable supply conditions and long cable runs. Feature: Built-in surge protection. Business Impact: Extends contact life and lowers maintenance costs by mitigating transient spikes. Application: Critical in industrial environments with unreliable mains or drive harmonics. Feature: Pre-mounted auxiliary contacts (2 NO / 2 NC). Business Impact: Reduces wiring effort and enables rapid integration with interlocks and signaling circuits. Application: Simplifies interfacing with PLCs and safety circuits. Feature: Block-type AF technology and extendable add-on contact blocks. Business Impact: Facilitates modular upgrades, compact panel layouts, and scalable control schemes. Application:cts for OEM assemblies and retrofit projects. Feature: Mechanical durability rated at 5 million operations; 300 cycles/hour maximum switching frequency. Business Impact: Long lifecycle with predictable maintenance windows, improving total cost of ownership. Application: Frequent motor start/stop cycles in conveyors and pumps. Feature: Rated Operational Power AC-3 up to 75 kW (1000 V), and AC-3e up to 90 kW. Business Impact: Enables larger motor capabilities from a single device, reducing panel count and wiring. Application: Heavy-duty process lines and packaging equipment. Feature: Weight and dimensions (90 mm wide, 126 mm deep, 150 mm high; 1.3 kg). Business Impact: Compact footprint supports space-constrained control panels and easier enclosure design. Application: OEM panels and retrofit projects with limited mounting depth.
Get a Quick Quote for a ABB 1SFL467062R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL467062R1122?
Enquire Now
FAQs
The AF146B-30-22RT-11 is a 3P block contactor with a 90 mm wide footprint using main circuit bars for the connections. It includes pre-mounted auxiliary contacts and a compact 150 mm tall enclosure, making it suitable for standard control panels. Ensure correct voltage ratings (main circuit, coil) and fitment with compatible add-on blocks for signaling or interlocking.
For AC-1 operation at 1000 V, the device supports up to 225 A at 40 °C (200 A at higher temperatures). For AC-3 operation, ratings include 60 A at 1000 V and 146 A at 415–440 V variants, with AC-3e delivering similar power profiles. These figures enable motor control up to 75 kW (AC-3) at rated voltages.
Yes. The coil accepts 24-60 V AC (50/60 Hz) and 20-60 V DC, offering resilience to control voltage fluctuations. This makes it well-suited for systems with long runs or unstable networks, reducing misoperation and unnecessary energy draw while preserving reliable switching.
The AF146B-30-22RT-11 carries IEC/EN 60947-1 and 60947-4-1 certifications, along with UL 60947-4-1 and CSA C22.2 No. 60947-4-1. Additional compliance references include EN 50155 applicability and related regional declarations; verify with ABB for part-specific approvals in your market.
ABB provides data sheets, operating instructions, and CAD drawings (2D/3D) for AF contactors. Access the resources via ABB’s product page or downloads section, where you’ll find the AF(S)116 to AF(S)146 manuals, dimensional drawings, and CAD files to streamline design and installation.