ABB AF146B-30-22-11 Contactor - IEC/UL 60947-4-1

Part Number: 1SFL467063R1122
Manufacturer
ABB
Part number
1SFL467063R1122

Quick Summary

ABB AF146B-30-22-11 Contactor is a 3-pole motor starter for controlling large motors up to 75 kW in industrial automation. Panel builders often face control voltage fluctuations and wasted energy; this AF family device tolerates wide control voltage ranges and includes built-in surge protection, reducing mis-trigger events and improving reliability. It meets IEC/EN 60947-4-1 and UL 60947-4-1, with CE declarations for global compliance, while additional marks such as UKCA and EAC support international installations. Designed for reliable motor protection and compact panel installation, with AC-3 duty ratings and easy expansion via auxiliary contacts for scalable control. This combination delivers improved uptime, predictable operation in harsh networks, and lower wiring complexity for scalable automation projects.

Product Information

Extended Description

1SFL467063R1122 ABB: The AF146B-30-22-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)116, AF140, AF(S)146
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
90 mm
Product Net Depth / Length
126 mm
Product Net Height
150 mm
Product Net Weight
1.55 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 225 A | (1000 V) 55 °C 200 A | (1000 V) 60 °C 200 A | (1000 V) 70 °C 175 A | (690 V) 40 °C 225 A | (690 V) 55 °C 200 A | (690 V) 60 °C 200 A | (690 V) 70 °C 175 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 146 A | (440 V) 55 °C 130 A | (500 V) 55 °C 130 A | (690 V) 55 °C 93 A | (1000 V) 55 °C 60 A | (380 / 400 V) 55 °C 146 A | (220 / 230 / 240 V) 55 °C 146 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 146 A | (440 V) 60 °C 146 A | (500 V) 60 °C 130 A | (690 V) 60 °C 93 A | (1000 V) 60 °C 54 A | (380 / 400 V) 60 °C 146 A | (220 / 230 / 240 V) 60 °C 146 A
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 200 A | (110 V) 2 Poles in Series, 60 °C 200 A | (110 V) 2 Poles in Series, 70 °C 175 A | (110 V) 3 Poles in Series, 40 °C 200 A | (110 V) 3 Poles in Series, 60 °C 200 A | (110 V) 3 Poles in Series, 70 °C 175 A | (175 V) 2 Poles in Series, 40 °C 200 A | (175 V) 2 Poles in Series, 60 °C 200 A | (175 V) 2 Poles in Series, 70 °C 175 A | (220 V) 3 Poles in Series, 40 °C 200 A | (220 V) 3 Poles in Series, 60 °C 200 A | (220 V) 3 Poles in Series, 70 °C 175 A | (260 V) 3 Poles in Series, 40 °C 200 A | (260 V) 3 Poles in Series, 60 °C 200 A | (260 V) 3 Poles in Series, 70 °C 175 A | (72 V) 1-Pole, 40 °C 200 A | (72 V) 1-Pole, 60 °C 200 A | (72 V) 1-Pole, 70 °C 175 A | (72 V) 2 Poles in Series, 40 °C 200 A | (72 V) 2 Poles in Series, 60 °C 200 A | (72 V) 2 Poles in Series, 70 °C 175 A | (72 V) 3 Poles in Series, 40 °C 200 A | (72 V) 3 Poles in Series, 60 °C 200 A | (72 V) 3 Poles in Series, 70 °C 175 A | (90 V) 1 Pole, 40 °C 200 A | (90 V) 1 Pole, 60 °C 200 A | (90 V) 1 Pole, 70 °C 175 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Operational Power AC-3e (Pe)
(415 V) 75 kW | (440 V) 90 kW | (500 V) 90 kW | (690 V) 90 kW | (1000 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Breaking Capacity AC-3e
8.5 x Ie AC-3e
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Making Capacity AC-3e
12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 225 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Power Loss
10 W | at Rated Operating Conditions per Pole 10 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 200 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 hp | (220 ... 240 V AC) Three Phase 50 hp | (440 ... 480 V AC) Three Phase 100 hp | (550 ... 600 V AC) Three Phase 125 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 120 A | (220 ... 240 V AC) Three Phase 130 A | (440 ... 480 V AC) Three Phase 124 A | (550 ... 600 V AC) Three Phase 125 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)116(B)-**(RT) to AF(S)205(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, AF(S)116-AF(S)146 (SE) Contactors
Improved Energy Efficiency for Customers
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 37 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF116 - AF146
CB Certificate
SEMKO_SE-70479M1
CQC Certificate
CQC Certificate, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF116-*-*-*, AF140-*-*-*, AF146-*-*-*, AF116B-*-*-*, AF140B-*-*-*, AF146B-*-*-*, AFS116-30-*-*,AFS140-30-*-*, AFS146-30-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
KC Certificate
KC Certificate, Contactor, AF146-30 (Sweden)
UL Certificate
cULus Certificate, Contactor, AF116-30...AF146-30, AFS116-30...AFS146-30
Package Level 1 Units
box 1 piece
Package Level 1 Width
207 mm
Package Level 1 Depth / Length
216 mm
Package Level 1 Height
150 mm
Package Level 1 Gross Weight
1.75 kg
Package Level 1 EAN
7320500511343
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210435
Feature: Three-pole main circuit rated at 1000 V with 60 A AC-3 capability and 75 kW PE. Benefit: Handles demanding motor loads with reliable switching, reducing maintenance and downtime in conveyors and pumps. Application: Suitable for high-power motor control in steel, manufacturing, and process lines. Feature: Wide control voltage range 24-60 V AC and 20-60 V DC. Benefit: Maintains consistent operation during voltage variations common in industrial facilities, improving control accuracy and energy efficiency. Application: Ideal for feedback-driven automation and panel systems exposed to network fluctuations. Feature: Built-in surge protection. Benefit: Protects downstream electronics and contact surfaces from voltage spikes, extending equipment life and reducing replacement costs. Application: Critical in welding stations, press lines, and heavy-pault machinery where transients are frequent. Feature: Pre-mounted auxiliary contacts (2 NO and 2 NC) and compatibility with add-on blocks. Benefit: Simplifies control circuit design and enables scalable logic without retrofitting. Application: Efficient for start/stop interlocks, auxiliary signaling, and remote control in complex automation. Feature: Block-type design with compact form factor and main circuit bars. Benefit: Saves panel space and streamlines wiring, enabling denser electrical cabinets. Application: Suitable for new builds and retrofits where space is at a premium. Feature: Robust mechanical durability (5 million cycles) and up to 300 cycles per hour. Benefit: Delivers long service life in high-cycle applications, reducing preventive maintenance needs. Application: Industrial automation lines with frequent cycling and high reliability requirements.

Get a Quick Quote for a ABB 1SFL467063R1122

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL467063R1122? Enquire Now

FAQs

To install the AF146B-30-22-11, mount the device in a standard 3P block, connect main circuit bars to the supply and load terminals, and attach the 2 NO/2 NC auxiliary contacts to the control circuit. Use add-on auxiliary contact blocks if you need expanded signaling. Ensure coil voltage matches the system control circuit (24-60 VAC or 20-60 VDC) and follow the IEC/EN 60947-4-1 guidelines for safe operation and proper electrical clearances.
For AC-3 at 1000 V, the AF146B-30-22-11 provides up to 60 A and 75 kW (typical at 415-1000 V depending on voltage/temperature), with lower current at higher ambient temperatures (e.g., 55 °C 60 A; 70 °C 175 A applicable in certain configurations). AC-1 ratings reach 225 A at 1000 V for general use. These figures enable accurate motor sizing and protected startup behavior.
Yes. The AF146B-30-22-11 is designed for heavy-duty motor control in AC-3 applications, common in conveyors and pumps. With 3P main contacts, predefined auxiliary contacts, and built-in surge protection, it delivers reliable start/stop sequences, reduces transients, and supports scalable control schemes essential for continuous operation in material handling and fluid pumping systems.
The AF146B-30-22-11 complies with IEC/EN 60947-1, IEC/EN 60947-4-1, and UL 60947-4-1, with CE and UKCA declarations for global acceptance. Verification involves checking the product labeling, manufacturer Declaration of Conformity, and the accompanying certificates (e.g., UL, CE). For specific country requirements, confirm with ABB representatives and reference the ABB EcoSolutions and CMRT/ RoHS documentation.
Maintenance benefits arise from a long mechanical life (about 5 million cycles) and low coil consumption, reducing wear and power draw. The built-in surge protection minimizes component damage, lowering replacement costs. ROI improves through reduced downtime, easier scalability with add-on auxiliary blocks, and simpler panel wiring, accelerating project timelines and delivering lower total cost of ownership.